Steady-State Simulation ​

Time-independent equilibrium calculations

Overview ​

Steady-state simulation calculates the equilibrium conditions of your wastewater treatment plant. It determines the operating point where all inputs, outputs, and internal states are constant over time.

When to Use ​

Ideal For ​

  • Plant sizing and design verification
  • Capacity analysis
  • Mass balance calculations
  • Equipment selection
  • Permit compliance checking
  • Baseline performance estimation

Not Suitable For ​

  • Diurnal variation effects
  • Startup/shutdown procedures
  • Controller tuning
  • Upset response analysis

Running Steady-State ​

Quick Start ​

  1. Build your process flow diagram
  2. Configure all unit properties
  3. Click Run Simulation (or press F5)
  4. Select Steady-State
  5. Click Start

Settings ​

SettingDefaultDescription
Tolerance0.01Convergence criterion
Max Iterations100Maximum solver iterations
RelaxationAutoUnder-relaxation factor
Initial GuessDefaultStarting point for iteration

Convergence ​

How It Works ​

The solver iteratively adjusts stream compositions until mass balance errors are below the tolerance:

Iteration 1:  Error = 15.2%
Iteration 5:  Error = 3.8%
Iteration 10: Error = 0.95%
Iteration 15: Error = 0.008% ✓ Converged

Convergence Indicators ​

StatusMeaning
ConvergedSolution found, error < tolerance
ConvergingError decreasing, continue
OscillatingError fluctuating, may need adjustment
DivergingError increasing, check configuration

Improving Convergence ​

  1. Simplify first: Start with fewer units
  2. Check connections: Ensure all streams connected
  3. Verify influent: Realistic compositions
  4. Reduce tolerance: Try 0.05 initially
  5. Initial conditions: Provide better guesses

Mass Balance ​

Verification ​

The solver ensures:

$$\sum \dot{m}{in} = \sum \dot{m} + \sum \dot{m}_{reaction}$$

For each component:

  • COD: Influent = Effluent + Oxidized + Sludge
  • N: Influent = Effluent + Denitrified + Sludge
  • P: Influent = Effluent + Sludge

Checking Balance ​

View mass balance table:

  1. Go to View > Mass Balance
  2. Check "Balance" column
  3. Values should be < 1%

Biokinetic Calculations ​

Basic Mode ​

Fixed efficiency calculations:

TSS_out = TSS_in × (1 - Removal_efficiency)

Advanced Mode ​

Full biokinetic model:

ASM1 Heterotrophic Growth: $$\mu_H = \mu_{max,H} \cdot \frac{S_S}{K_S + S_S} \cdot \frac{S_O}{K_{O,H} + S_O}$$

Steady-State Biomass: $$X_{BH} = \frac{Y_H \cdot (S_{S,in} - S_{S})}{1 + b_H \cdot SRT}$$

Results ​

Stream Results ​

Each stream displays:

  • Flow rate (m3/d)
  • All component concentrations
  • Mass flow rates

Unit Results ​

Each unit shows:

  • Removal efficiencies
  • Operating conditions
  • Capacity utilization
  • Energy consumption

Export Options ​

FormatUse
CSVSpreadsheet analysis
ExcelFormatted report
PDFDocumentation
JSONProgrammatic access

Typical Applications ​

Design Verification ​

  1. Size units for design flow
  2. Run steady-state simulation
  3. Check effluent quality vs. limits
  4. Verify capacity margins

Scenario Comparison ​

  1. Create base case
  2. Duplicate project
  3. Modify parameters
  4. Compare results side-by-side

Sensitivity Analysis ​

  1. Identify key parameter
  2. Vary over range (e.g., ±20%)
  3. Run multiple steady-states
  4. Plot response curve

Example: MLE Plant ​

Configuration ​

UnitSize
Anoxic Zone2,000 m3
Aerobic Zone6,000 m3
Secondary Clarifier1,200 m2
RAS100%
IRR200%

Influent ​

ParameterValue
Flow20,000 m3/d
COD400 mg/L
TKN40 mg/L
TP8 mg/L

Results ​

ParameterEffluentLimit
TSS8 mg/L30 mg/L
BOD5 mg/L20 mg/L
NH4-N1.2 mg/L5 mg/L
TN8 mg/L10 mg/L

Troubleshooting ​

Common Issues ​

IssueCauseSolution
Not convergingLarge recycle loopAdd initial guess
Negative concentrationInvalid parametersCheck kinetics
Mass imbalanceDisconnected streamVerify connections
High TSS in effluentClarifier underloadedCheck SOR
Poor N removalLow SRTIncrease sludge age

Debugging Steps ​

  1. Check all streams connected
  2. Verify influent complete
  3. Run with Basic mode first
  4. Enable detailed logging
  5. Check unit by unit

Best Practices ​

  1. Start simple: Basic mode, simple configuration
  2. Build up: Add complexity gradually
  3. Verify each step: Check mass balance frequently
  4. Document assumptions: Note key parameters
  5. Save checkpoints: Before major changes

References ​

  1. Henze, M. "Activated Sludge Models ASM1, ASM2, ASM2d and ASM3"
  2. Grady, C.P.L. "Biological Wastewater Treatment" (3rd Edition)
  3. Tchobanoglous, G. "Wastewater Engineering" (5th Edition)