Skip to content

Chemical Dosing - Phosphorus Removal ​

Chemical precipitation is used for phosphorus (P) removal in wastewater treatment, typically using ferric or aluminum salts. This guide focuses on ferric sulphate dosing following UK water industry operational guidelines.

UK Industry Molar Ratio Standards ​

Fe:P Molar Ratios by Dosing Stage ​

Dosing StageMinimumTypicalMaximumTarget P Removal
Primary1.501.661.8060-80%
Secondary1.601.802.0070-90%
Tertiary1.802.002.2080-95%

General principle:

  • Higher Fe:P ratios → Higher P removal efficiency
  • Later stages require higher ratios for diminishing returns
  • Typical practice: Use 1.66:1 for primary or secondary dosing

###Alternative Coagulants

ChemicalFormulaFe/Al ContentMolar Ratio (M:P)Notes
Ferric sulphateFe₂(SO₄)₃12% Fe1.5-2.2 (Fe:P)Most common in UK
Ferric chlorideFeCl₃38-45% Fe1.5-2.2 (Fe:P)Higher Fe content, more corrosive
Aluminum sulphateAl₂(SO₄)₃8% Al1.5-2.5 (Al:P)Alternative to Fe, common in drinking water
PACAl_n(OH)_m(Cl)₃ₙ₋ₘ10% Al1.5-2.5 (Al:P)Polyaluminum chloride, wide pH range

Design Equations ​

Core Dosing Calculations ​

Iron Dose from P Load ​

Formula:

Fe_dose = P_load × (Fe:P ratio) × (MW_Fe / MW_P)

Where:

  • Fe_dose = iron required (kg Fe/d)
  • P_load = phosphorus to be removed (kg P/d)
  • Fe:P ratio = molar ratio (e.g., 1.66)
  • MW_Fe = molar mass of Fe = 56 g/mol
  • MW_P = molar mass of P = 31 g/mol
  • MW_Fe / MW_P = 56/31 = 1.806

Example:

P_load = 10 kg/d
Fe:P ratio = 1.66 (typical)

Fe_dose = 10 × 1.66 × 1.806 = 29.98 kg Fe/d

Compound Dose from Fe Dose ​

Formula:

Compound_dose = Fe_dose / (Fe_content / 100)

Where:

  • Compound_dose = ferric sulphate required (kg/d)
  • Fe_content = % Fe in compound (typically 12% for ferric sulphate)

Example (ferric sulphate at 12% Fe):

Fe_dose = 30 kg Fe/d
Fe_content = 12%

Compound_dose = 30 / 0.12 = 250 kg ferric sulphate/d

Volumetric Dosing Rate ​

Formula:

Dose_rate = Compound_dose / Density / 24

Where:

  • Dose_rate = volumetric dosing rate (L/h)
  • Density = solution density (kg/L, typically 1.5 for ferric sulphate)

Example:

Compound_dose = 250 kg/d
Density = 1.5 kg/L

Dose_rate = 250 / 1.5 / 24 = 6.94 L/h

Dosing Stage Selection ​

Primary Stage Dosing ​

Location: Dosed into primary sedimentation tanks

Advantages:

  • Simultaneous P and SS removal
  • Enhanced primary sludge settleability
  • H₂S odor control (bonus benefit)
  • Lower overall sludge volume vs later stages

Disadvantages:

  • Lower P removal efficiency (60-80%)
  • Higher chemical consumption for given removal
  • No BOD enhancement

Typical application:

  • Works with primary treatment
  • Moderate P consents (≤ 2 mg/L)
  • Where sludge minimization is priority

Fe:P ratio: 1.66:1 (typical)

Secondary Stage Dosing ​

Location: Dosed into biofilter effluent or humus tanks

Advantages:

  • Higher P removal efficiency (70-90%)
  • Improved humus sludge settlement
  • Can retrofit to existing works

Disadvantages:

  • Chemical sludge separate from primary
  • May interfere with biofilter performance if overdosed
  • Requires good mixing

Typical application:

  • Biofilter works without primary treatment
  • Stricter P consents (≤ 1 mg/L)
  • Retrofit applications

Fe:P ratio: 1.80:1 (typical)

Tertiary Stage Dosing ​

Location: Dosed after all biological treatment (polishing)

Advantages:

  • Highest P removal (80-95%)
  • Fine-tuning to meet very low consents
  • No interference with biological processes

Disadvantages:

  • Highest chemical consumption per kg P removed
  • Additional settling/filtration required
  • Separate sludge handling

Typical application:

  • Very strict P consents (≤ 0.5 mg/L)
  • Sensitive receiving waters (eutrophic lakes)
  • Works with advanced treatment trains

Fe:P ratio: 2.00:1 (typical)


P Removal Efficiency ​

Efficiency by Stage and Ratio ​

Primary dosing:

Efficiency (%) = 60 + 20 × ((ratio - 1.5) / (1.8 - 1.5))

Range: 60-80%

Secondary dosing:

Efficiency (%) = 70 + 20 × ((ratio - 1.6) / (2.0 - 1.6))

Range: 70-90%

Tertiary dosing:

Efficiency (%) = 80 + 15 × ((ratio - 1.8) / (2.2 - 1.8))

Range: 80-95%

Example (primary, Fe:P = 1.66):

Efficiency = 60 + 20 × ((1.66 - 1.5) / 0.3)
Efficiency = 60 + 20 × 0.533 = 70.7%

Effluent P Calculation ​

Formula:

P_effluent = P_influent × (1 - E/100)

Example:

P_influent = 12 mg/L
Efficiency = 70%

P_effluent = 12 × (1 - 0.70) = 3.6 mg/L

Chemical Sludge Production ​

Sludge from Ferric Sulphate ​

Formula:

Sludge_production = Fe_dose × S_factor

Where:

  • Sludge_production = chemical sludge (kgSS/d)
  • Fe_dose = iron dosed (kg Fe/d)
  • S_factor = sludge factor = 2.3 kgSS/kg Fe (typical)

Derivation:

Fe precipitation: Fe³⁺ + PO₄³⁻ → FePO₄ (solid)
Fe hydrolysis: Fe³⁺ + 3OH⁻ → Fe(OH)₃ (solid)
Combined: 1 kg Fe → ~2.3 kg dry solids

Example:

Fe_dose = 30 kg Fe/d

Sludge = 30 × 2.3 = 69 kgSS/d

Combined with primary sludge:

Total_sludge = Primary_sludge + Chemical_sludge
Total_sludge = 105 + 69 = 174 kgSS/d

Storage Requirements ​

Chemical Storage Tank Sizing ​

UK operator standard: 28 days storage minimum

Formula:

Storage_volume = Compound_dose × Storage_days / Density / 1000

Where:

  • Storage_volume = tank capacity (m³)
  • Storage_days = typically 28 days (UK operator)
  • Density = solution density (kg/L)

Example:

Compound_dose = 250 kg/d
Storage_days = 28 days
Density = 1.5 kg/L

Storage = (250 × 28) / 1.5 / 1000 = 4.67 m³

Delivery Mass ​

Formula:

Delivery_mass = Storage_volume × Density

Where:

  • Delivery_mass = tanker delivery (tonnes)

Example:

Storage = 4.67 m³
Density = 1.5 kg/L = 1,500 kg/m³ = 1.5 tonnes/m³

Delivery = 4.67 × 1.5 = 7.0 tonnes per delivery

Delivery frequency:

Frequency = Storage_days = 28 days (~ monthly)

Worked Example ​

Design Basis ​

  • Population: 5,000 PE
  • DWF: 600 m³/d
  • Influent TP: 12 mg/L
  • Target effluent TP: ≤ 2 mg/L (consent)
  • Dosing stage: Primary
  • Chemical: Ferric sulphate (12% Fe)

Step 1: Calculate P Load ​

Influent load:

P_inf = (12 mg/L × 600 m³/d) / 1000 = 7.2 kg P/d

Target effluent:

P_eff = 2 mg/L
P_eff_load = (2 mg/L × 600 m³/d) / 1000 = 1.2 kg P/d

P to be removed:

P_removal = 7.2 - 1.2 = 6.0 kg P/d
Removal efficiency = 6.0 / 7.2 × 100 = 83.3%

Step 2: Select Fe:P Ratio ​

For primary dosing to achieve 83% removal:

Target E = 83%
Primary range: 60-80% typical

Use higher end ratio: Fe:P = 1.75 (between typical 1.66 and max 1.80)

Step 3: Calculate Fe Dose ​

Formula:

Fe_dose = P_removal × Fe:P × (56/31)
Fe_dose = 6.0 × 1.75 × 1.806
Fe_dose = 18.96 kg Fe/d ≈ 19 kg Fe/d

Step 4: Calculate Compound Dose ​

Ferric sulphate (12% Fe):

Compound = 19 / 0.12 = 158.3 kg/d

Step 5: Calculate Dosing Rate ​

Volumetric rate:

Dose_rate = 158.3 / 1.5 / 24 = 4.40 L/h

Daily volume:

Daily_volume = 4.40 × 24 = 105.6 L/d

Step 6: Calculate Storage ​

28-day storage:

Storage = (158.3 × 28) / 1.5 / 1000 = 2.95 m³

Select: 3.0 m³ tank (with 2% margin)

Delivery mass:

Delivery = 3.0 × 1.5 = 4.5 tonnes per month

Step 7: Calculate Chemical Sludge ​

Sludge production:

Chem_sludge = 19 × 2.3 = 43.7 kgSS/d

Impact on primary sludge: Assuming 105 kgSS/d from primary alone:

Total_primary = 105 + 43.7 = 148.7 kgSS/d
Increase = 43.7 / 105 × 100 = 42% increase

Combined sludge flow (3% DS):

Sludge_flow = (148.7 / 1000) / 0.03 = 4.96 m³/d
(vs 3.5 m³/d without chemical)

Step 8: Verify Compliance ​

Predicted effluent TP: Using Fe:P = 1.75 for primary:

Efficiency ≈ 78% (from correlation)
P_eff = 12 × (1 - 0.78) = 2.64 mg/L

This is above target of 2.0 mg/L.

Adjustment: Increase to Fe:P = 1.80 (max for primary)

Fe_dose = 6.0 × 1.80 × 1.806 = 19.5 kg Fe/d
Efficiency ≈ 80%
P_eff = 12 × (1 - 0.80) = 2.4 mg/L

Still above target. Consider secondary dosing instead:

Using secondary dosing with Fe:P = 1.80:

Efficiency ≈ 80% (secondary range: 70-90%)
P_eff = 12 × (1 - 0.80) = 2.4 mg/L

Or Fe:P = 1.90:

Efficiency ≈ 85%
P_eff = 12 × (1 - 0.85) = 1.8 mg/L ✓

Revised Design Summary ​

ParameterValueNotes
Dosing stageSecondary (humus tanks)For higher efficiency
Fe:P molar ratio1.90Between typical 1.80 and max 2.00
P removal efficiency85%
Fe dose20.6 kg Fe/d
Compound dose171.7 kg/dFerric sulphate (12% Fe)
Dosing rate4.77 L/h
Storage tank3.2 m³28 days @ 1.5 kg/L density
Delivery frequencyMonthly4.8 tonnes per delivery
Chemical sludge47.4 kgSS/d
Predicted effluent TP1.8 mg/L✓ Meets 2.0 mg/L consent

UK Water Company Variations ​

UK Industry Practice ​

  • Fe:P ratios as specified above (1.5-2.2)
  • 28-day chemical storage mandatory
  • Prefer secondary dosing for P removal
  • Monthly site visits for performance verification

UK Industry Practice ​

  • Similar Fe:P ratios
  • Often use aluminum sulphate in some catchments
  • Require detailed mass balance for consent compliance
  • Continuous P monitoring on larger works

UK Industry Practice ​

  • Use ferric chloride in some areas (higher Fe%)
  • Prefer primary dosing where compatible with sludge treatment
  • Strict reporting on chemical consumption

Design Considerations ​

Dosing Point Selection ​

Primary tanks:

  • Dose at inlet channel or distribution chamber
  • Good mixing from inlet turbulence
  • Rapid precipitation and co-settlement
  • Monitor primary sludge density (target 4-6% DS)

Biofilter effluent:

  • Dose before humus tanks
  • Ensure good mixing (baffled channel or static mixer)
  • Allow 10-20 minutes contact time
  • Monitor humus sludge for Fe accumulation

Tertiary (after humus):

  • Dose into separate contact tank
  • Provide flocculation (gentle mixing, 15-30 min)
  • Followed by settlement or filtration
  • Separate sludge handling required

Mixing Requirements ​

Rapid mix:

  • G value: 300-600 s⁻¹
  • Time: 30-60 seconds
  • Purpose: Distribute chemical, initiate precipitation

Flocculation:

  • G value: 20-60 s⁻¹
  • Time: 15-30 minutes
  • Purpose: Grow settleable flocs

Equation for mixing intensity:

G = √(P / μ / V)

Where:

  • G = velocity gradient (s⁻¹)
  • P = power input (W)
  • μ = dynamic viscosity (Pa·s)
  • V = tank volume (m³)

pH Considerations ​

Optimal pH ranges:

  • Ferric salts: pH 5.0-8.5 (optimal 6.0-7.5)
  • Aluminum salts: pH 5.5-7.5 (optimal 6.0-7.0)

pH depression from dosing: Ferric sulphate is acidic and consumes alkalinity:

Alkalinity consumed = Fe_dose × 0.75 kg CaCO₃/kg Fe

See Alkalinity Balance for full calculation.

Example:

Fe_dose = 20 kg Fe/d
Alk consumed = 20 × 0.75 = 15 kg CaCO₃/d

If this drives effluent pH < 6.5 or alkalinity < 50 mg/L, add lime or caustic soda.

Alkalinity and Bicarbonate Dosing ​

If pH falls below optimal:

Lime addition:

Lime_dose = Alkalinity_deficit / 0.74

Where 0.74 converts CaCO₃ equivalent to CaO.

Caustic soda alternative:

NaOH_dose = Alkalinity_deficit / 1.25

Where 1.25 converts CaCO₃ to NaOH equivalent.


Dosing Equipment ​

Dosing Pumps ​

Types:

  • Diaphragm metering pumps (most common)
  • Peristaltic pumps (lower capacity)
  • Progressive cavity pumps (higher capacity)

Sizing:

  • Max flow: 150-200% of average dose rate (turndown 10:1)
  • Example: Average 5 L/h → Select 10 L/h max pump
  • Redundancy: Minimum 2 pumps (duty + standby)

Control:

  • Flow-proportional dosing (most common)
  • Compound loop (P analyzer feedback, optional)
  • Manual trim adjustment (±20%)

Storage and Handling ​

Tank material:

  • Ferric sulphate: HDPE, GRP (not mild steel)
  • Level indication: Ultrasonic or pressure transmitter
  • Bunding: 110% of tank capacity

Safety:

  • Ferric sulphate: Corrosive, pH ~2
  • PPE: Goggles, gloves, apron
  • Spillage: Neutralize with lime, wash down
  • Ventilation: Adequate for fumes (acidic vapor)

Monitoring and Control ​

Key Parameters ​

ParameterFrequencyMethodTarget
Influent TPDailyLaboratoryBaseline
Effluent TPDailyLaboratory< Consent limit
Fe dose rateContinuousPump stroke counterPer design
Chemical stockWeeklyLevel gauge> 7 days
Sludge %DSWeeklyLaboratory4-6% (primary)

Optimization ​

Jar testing:

  • Periodic jar tests to verify optimal Fe:P ratio
  • Especially after significant influent changes
  • Test range: ±20% around design ratio

Dose trimming:

If effluent TP consistently < target: Reduce dose by 10%
If effluent TP > target: Increase dose by 10%
Repeat until stable at target ± 15%

Cost optimization:

Chemical_cost = Compound_dose × Unit_price

Typical ferric sulphate: £150-200/tonne

Example:

Dose = 170 kg/d = 5.1 tonnes/month
Price = £180/tonne
Monthly cost = 5.1 × £180 = £918/month

Common Dosing Issues ​

Over-Dosing ​

Symptoms:

  • Effluent TP well below consent (wasted chemical)
  • Yellow/brown color in effluent (residual Fe)
  • Excessive sludge production

Solutions:

  • Reduce Fe:P ratio
  • Check influent TP (may have decreased)
  • Optimize based on effluent monitoring

Under-Dosing ​

Symptoms:

  • Effluent TP exceeds consent
  • Poor sludge settlement (insufficient coagulation)

Solutions:

  • Increase Fe:P ratio
  • Check for short-circuiting (poor mixing)
  • Verify pump calibration and chemical strength

Poor Mixing ​

Symptoms:

  • Variable effluent TP
  • Poor sludge settlement (incomplete precipitation)
  • Chemical accumulation in corners

Solutions:

  • Add static mixer or baffle
  • Increase dosing point turbulence
  • Relocate dose point to higher energy zone

Sludge Handling Issues ​

Symptoms:

  • Sludge difficult to thicken (Fe-rich sludge)
  • Dewatering problems (high Fe binds water)

Solutions:

  • Optimize Fe dose (avoid over-dosing)
  • Add polymer for dewatering (5-15 kg/tonne DS)
  • Consider lime stabilization before dewatering


References ​

  • UK operator Operational Guidelines: Chemical dosing for phosphorus removal
  • CIWEM Best Practice: Ferric and aluminum dosing in wastewater treatment
  • WRc Technical Guidance: Chemical phosphorus removal

Navigation: