Lamella Primary Clarifier ​

Inclined plate settler with dramatically increased effective settling area for compact, high-rate primary treatment.

Overview ​

The lamella (inclined plate) clarifier uses closely-spaced inclined plates to multiply the effective settling area, allowing much higher surface overflow rates (SOR) in a compact footprint. This technology is ideal for space-constrained sites or as a retrofit to increase existing plant capacity.

When to Use ​

  • Space-constrained sites
  • Capacity upgrades to existing plants
  • High-rate primary treatment
  • Storm water treatment
  • Industrial pretreatment

Key Advantages ​

  • 5-10× higher SOR than conventional clarifiers
  • 60-80% smaller footprint
  • Rapid construction (modular options)
  • Effective for storm water peaks

Settling Theory ​

Inclined Plate Settling ​

The effective settling area is multiplied by the number of plate passages:

$$A_{effective} = A_{horizontal} \times n \times \cos(\theta)$$

Where:

  • $n$ = number of plate channels
  • $\theta$ = plate angle from horizontal (typically 55-60°)

Modified Hazen Theory ​

Particle removal in lamella settlers follows modified Hazen theory:

$$\eta = \frac{V_s}{SOR_{actual}} \times \frac{L}{d} \times \cos(\theta) \times \sin(\theta)$$

Where:

  • $L$ = plate length (m)
  • $d$ = plate spacing (m)
  • $\theta$ = plate angle (°)

Simplifies to:

$$\eta = \frac{V_s \times L \times \sin(2\theta)}{2 \times SOR \times d}$$

Critical Settling Velocity ​

The minimum particle settling velocity captured:

$$V_{s,critical} = \frac{Q}{A_{effective}} = \frac{Q \times d}{W \times L \times n \times \cos(\theta) \times \sin(\theta)}$$

Design Equations ​

Effective Surface Overflow Rate ​

The actual SOR is much higher than conventional:

$$SOR_{actual} = \frac{Q}{A_{footprint}}$$

But the effective SOR considering plates:

$$SOR_{effective} = \frac{Q}{A_{effective}} = \frac{SOR_{actual}}{n \times \cos(\theta)}$$

Plate Geometry ​

Number of Channels: $$n = \frac{H_{plate zone}}{d + t}$$

Where:

  • $H_{plate zone}$ = height of plate zone (m)
  • $d$ = clear spacing between plates (m)
  • $t$ = plate thickness (m)

Plate Length (vertical projection): $$L_{vertical} = L \times \sin(\theta)$$

Hydraulic Loading ​

Per-channel velocity: $$v_{channel} = \frac{Q}{W \times n \times d}$$

Design limit: $v_{channel} < 0.02$ m/s to prevent solids resuspension.

Sludge Slide-off ​

Plates must be angled to allow sludge to slide off:

$$\theta > \arctan(\mu)$$

Where $\mu$ = coefficient of friction (typically 0.7-1.0 for primary sludge)

Minimum angle: 50° (typically 55-60° used)

Parameters ​

Geometric Parameters ​

ParameterSymbolUnitRangeDefaultDescription
Plate LengthLm1.0-3.02.0Along flow path
Plate Spacingdmm40-10050Clear spacing
Plate Angleθ°50-7060From horizontal
Plate Thicknesstmm2-63Material dependent
Plate Zone HeightHm1.5-4.02.5Vertical extent
Tank WidthWm2-105Flow width
Number of TanksN-1-42For redundancy

Hydraulic Parameters ​

ParameterUnitTypical RangeNotes
Actual SORm³/m²/h5-15On footprint area
Effective SORm³/m²/h0.5-1.5On plate area
Channel Velocitym/s0.01-0.02In plate channels
HRT (plate zone)min10-30Shorter than conventional

Advanced Parameters ​

ParameterUnitDefaultRangeDescription
plateEfficiencyFactor-0.850.7-0.95Account for edge effects
sludgeRemovalMethod-hopperhopper/continuousCollection method
flocculationZonebooltrue-Pre-settling zone
flocZoneHRTmin105-20Floc formation time
distributionMethod-weirweir/manifoldFlow distribution

Particle Size Distribution ​

Lamella clarifiers effectively remove particles across the distribution:

Settling Velocity (m/h)Conventional RemovalLamella Removal
0.1 (colloidal)5%15%
0.5 (fine)30%60%
2.0 (medium)85%98%
5.0 (coarse)98%100%
10.0 (very coarse)100%100%

Removal Efficiencies ​

Primary Treatment Application ​

ParameterRemoval (%)Notes
BOD20-30Lower contact time
TSS50-70Good solids removal
COD20-35Particulate fraction
NH₃-N0Not removed
Total P10-15Particulate only

With Chemical Addition ​

ParameterRemoval (%)Notes
BOD30-40Enhanced
TSS70-85Excellent with chemicals
COD30-45Enhanced
NH₃-N0Not affected
Total P70-90Primary mechanism

Storm Water Treatment ​

Lamella clarifiers excel at storm water peaks:

ParameterRemoval (%)
TSS60-80
Grit95-100
Floatables80-95

Configuration ​

Zones ​

mermaid
graph TB
    subgraph Lamella Clarifier
        A[Inlet Zone] --> B[Flocculation Zone]
        B --> C[Plate Settling Zone]
        C --> D[Clarified Water Zone]
        C --> E[Sludge Hopper]
    end
    style C fill:#e1f5fe
  1. Inlet Zone: Flow distribution and energy dissipation
  2. Flocculation Zone: Gentle mixing for particle aggregation (10-20 min HRT)
  3. Plate Settling Zone: Inclined plates for high-rate settling
  4. Clarified Water Zone: Collection of treated effluent
  5. Sludge Hopper: Collection of settled solids

Step-by-Step Setup ​

  1. Define Flow Requirements

    • Peak flow capacity
    • Average flow for efficiency calc
    • Storm flow handling
  2. Size Plate Zone

    • Select plate angle (55-60°)
    • Choose plate spacing (40-80mm)
    • Calculate required plate area
  3. Add Support Zones

    • Inlet/distribution
    • Flocculation (if needed)
    • Sludge collection
  4. Verify Hydraulics

    • Check channel velocity < 0.02 m/s
    • Verify effective SOR
    • Confirm sludge slide-off angle

Example Configuration ​

json
{
  "type": "primaryClarifierLamella",
  "parameters": {
    "tankLength": 8,
    "tankWidth": 5,
    "plateLength": 2.0,
    "plateSpacing": 50,
    "plateAngle": 60,
    "plateZoneHeight": 2.5,
    "numberOfTanks": 2,
    "chemicalDosing": false,
    "calculationMode": "advanced",
    "advancedParams": {
      "plateEfficiencyFactor": 0.85,
      "flocculationZone": true,
      "flocZoneHRT": 15,
      "sludgeRemovalMethod": "continuous"
    }
  }
}

Worked Example ​

Given ​

  • Design flow: 5,000 m³/d (peak: 10,000 m³/d)
  • Space available: 10m × 6m footprint
  • Influent TSS: 350 mg/L

Design ​

Step 1: Plate Configuration

  • Plate angle: 60°
  • Plate spacing: 50mm
  • Plate thickness: 3mm
  • Plate zone height: 2.5m

Number of channels: $$n = \frac{2.5}{0.050 + 0.003} = 47 \text{ channels}$$

Step 2: Calculate Effective Area

Tank width: 5m, Plate length: 2.0m

$$A_{effective} = 5 \times 2.0 \times 47 \times \cos(60°) = 235 \text{ m}^2$$

Step 3: Check SOR

Footprint area: $A = 10 \times 6 = 60$ m²

At design flow: $$SOR_{actual} = \frac{5,000}{60} = 83.3 \text{ m³/m²/d}$$

$$SOR_{effective} = \frac{5,000}{235} = 21.3 \text{ m³/m²/d}$$

Equivalent to conventional: ✓

Step 4: Check Channel Velocity

Per-channel flow at peak: $$Q_{channel} = \frac{10,000}{86,400 \times 47} = 0.00246 \text{ m³/s per meter width}$$

$$v_{channel} = \frac{0.00246}{0.05} = 0.049 \text{ m/s}$$

⚠ Exceeds 0.02 m/s limit at peak - need larger plates or more tanks.

Step 5: Revised Design

Add second tank (2 × 60 m²):

$$v_{channel} = 0.025 \text{ m/s}$$ ✓ (marginally acceptable for peak)

Step 6: Estimate Removal

At effective SOR of 21 m³/m²/d:

  • TSS removal: ~65%
  • BOD removal: ~25%

Sludge Handling ​

Collection Methods ​

Hopper Collection:

  • Sludge slides to hopper
  • Batch withdrawal
  • Simple, reliable

Continuous Removal:

  • Scraper mechanism
  • Continuous withdrawal
  • Better for high solids loads

Sludge Characteristics ​

ParameterValueUnit
Concentration1-3% DS
Withdrawal Rate0.5-2% of flow
Density1010-1030kg/m³

Maintenance Considerations ​

Plate Cleaning ​

  • Frequency: Every 3-12 months
  • Methods: High-pressure water, air scour, manual
  • Access: Removable plate packs preferred

Common Issues ​

IssueCauseSolution
Reduced efficiencyPlate foulingClean plates
Sludge buildupInsufficient angleIncrease withdrawal
Short-circuitingPoor distributionImprove inlet
Algae growthLight exposureCover tank

Comparison with Conventional ​

ParameterConventionalLamellaRatio
Footprint100%15-25%4-7× smaller
SOR (actual)30-50 m³/m²/d150-300 m³/m²/d5-10× higher
HRT2-4 hours15-45 min4-8× shorter
TSS Removal50-65%50-70%Similar
Capital Cost100%80-120%Variable
Operating Cost100%90-110%Similar

Applications ​

Retrofit/Upgrade ​

Ideal for increasing existing plant capacity:

$$Capacity_{new} = Capacity_{old} + A_{lamella} \times SOR_{lamella}$$

Can add 50-200% capacity with small footprint.

Storm Water Treatment ​

High-rate capability handles storm peaks:

  • Flow equalization not always needed
  • Rapid response to flow changes
  • Good grit and floatables removal

Industrial Pretreatment ​

Compact size suits industrial applications:

  • Food processing
  • Paper mills
  • Chemical plants

Best Practices ​

  1. Plate Angle: Use 55-60° for reliable sludge release
  2. Spacing: Wider spacing (80-100mm) reduces clogging risk
  3. Flocculation: Include pre-flocculation zone for best results
  4. Flow Distribution: Critical for even loading
  5. Cleaning Access: Design for easy plate removal
  6. Covers: Prevent algae in outdoor installations

References ​

  1. Metcalf & Eddy (2014). Wastewater Engineering: Treatment and Resource Recovery, 5th Ed.
  2. Yao, K.M. (1970). "Theoretical Study of High-Rate Sedimentation". JWPCF
  3. WEF (2018). Design of Municipal Wastewater Treatment Plants, MOP 8
  4. Parkson Corporation. Lamella Gravity Settler Design Manual
  5. UK Water Industry Research (2003). High Rate Clarifiers in Sewage Treatment