Skip to content

Grit Chamber ​

Horizontal flow sedimentation basin for removal of heavy inorganic particles (sand, gravel, grit) while keeping organic solids in suspension.

Overview ​

Grit chambers protect downstream equipment from abrasive wear, reduce grit accumulation in tanks and digesters, and minimize solids disposal costs by separating heavy inorganic material. The key design principle is controlled horizontal velocity to settle grit while keeping lighter organic matter suspended.

When to Use ​

  • All municipal wastewater treatment plants
  • Industrial plants with sand/grit in influent
  • Combined sewer systems (high grit loads)
  • Before pumps requiring protection
  • Upstream of primary clarifiers and aeration tanks
  • Pretreatment for anaerobic digesters

Key Characteristics ​

  • Removes particles >0.21mm at specific gravity ~2.65
  • Controlled horizontal velocity (0.15-0.45 m/s)
  • Minimal organic matter removal
  • Simple, reliable operation
  • Requires grit washing and disposal

Operating Modes ​

Basic Mode ​

  • Fixed removal efficiency (default 95% >0.21mm)
  • Simplified detention time calculation
  • Constant horizontal velocity

Advanced Mode ​

  • Stokes' Law settling calculations
  • Particle size distribution tracking
  • Temperature-dependent viscosity
  • Scour velocity verification

Mathematical Model ​

Governing Equation - Stokes' Settling Velocity ​

$$V_s = \frac{g \times d^2 \times (\rho_s - \rho_w)}{18 \mu}$$

Where:

  • $V_s$ = terminal settling velocity (m/s)
  • $g$ = gravitational acceleration (9.81 m/s²)
  • $d$ = particle diameter (m)
  • $\rho_s$ = particle density (kg/m³)
  • $\rho_w$ = water density (kg/m³, ~1000)
  • $\mu$ = dynamic viscosity of water (Pa·s)

Temperature Correction for Viscosity ​

$$\mu(T) = \mu_{20} \times \frac{1.002 \times 10^{-3}}{(1.002 - 0.02393 \times T + 0.000146 \times T^2) \times 10^{-3}}$$

Simplified: $$\mu(T) \approx 0.00179 - 0.0000535 \times T + 0.000000367 \times T^2$$

Where T is in °C.

Critical Parameters ​

Standard design particle:

  • Diameter: 0.21mm (210 µm)
  • Specific gravity: 2.65
  • At 20°C: V_s ≈ 0.021 m/s (21 mm/s)
  • At 10°C: V_s ≈ 0.016 m/s (reduced due to higher viscosity)

Detention Time ​

$$t = \frac{d}{V_s}$$

Where:

  • $t$ = detention time (s)
  • $d$ = effective water depth (m)

Required Length ​

$$L = v_h \times t = v_h \times \frac{d}{V_s}$$

Where:

  • $L$ = chamber length (m)
  • $v_h$ = horizontal velocity (m/s)

Surface Loading Rate ​

$$SLR = \frac{Q}{W \times L}$$

Where:

  • $SLR$ = surface loading rate (m³/m²/h)
  • $Q$ = flow rate (m³/h)
  • $W$ = chamber width (m)

Design Parameters ​

Input Parameters ​

ParameterSymbolUnitRangeDefaultDescription
Horizontal velocityv_hm/s0.15-0.450.30Controlled flow velocity
Water depthdm1.0-2.51.5Effective settling depth
Detention timets30-9060At peak flow
Chamber widthWm2.0-10.06.0Cross-sectional width
TemperatureT°C5-2515Wastewater temperature
Target particled_pmm0.15-0.300.21Design grit size

Output Parameters ​

ParameterUnitDescription
Grit removal%Fraction of particles >0.21mm removed
Chamber lengthmRequired length for settling
Grit volumem³/dVolume of grit removed
Grit masskg/dMass of grit for disposal
Scour velocity check-Verification that organics stay suspended

Configuration Guide ​

Step-by-Step Setup ​

  1. Select Horizontal Velocity

    • Standard: 0.30 m/s (most common)
    • Low: 0.15-0.25 m/s (light grit loads)
    • High: 0.35-0.45 m/s (heavy grit, combined sewers)
    • Critical: Must be constant regardless of flow variation
  2. Determine Detention Time

    • At peak hourly flow: 45-90 seconds
    • Typical: 60 seconds
    • Colder climates: Increase 15-20% (higher viscosity)
  3. Calculate Dimensions

    • Depth: 1.0-2.0m (based on site constraints)
    • Width: From flow and velocity control
    • Length: From detention time and velocity
  4. Select Flow Control Method

    • Proportional weir: V-notch or sutro weir at outlet
    • Parshall flume: Maintains constant velocity
    • Variable gates: Adjustable for flow changes
  5. Design Grit Removal System

    • Manual: Bucket elevator or screw conveyor
    • Automatic: Air-lift, screw, or chain-bucket
    • Washing: Classify and wash to <5% organics
  6. Configure Multiple Channels

    • Minimum 2 channels for redundancy
    • Splitter box for equal distribution
    • Isolation gates for maintenance

Typical Design Values ​

ApplicationVelocityDetentionDepthSLRGrit Yield
Municipal (separate sewer)0.30 m/s60s1.5m900 m³/m²/h4-15 L/1000m³
Combined sewer0.35 m/s45s1.8m700 m³/m²/h20-90 L/1000m³
Industrial (food)0.25 m/s75s1.2m600 m³/m²/h5-30 L/1000m³

Velocity Control Methods ​

Proportional Weir (Most Common):

  • V-notch or sutro weir at effluent end
  • Maintains constant upstream velocity
  • Simple, no moving parts
  • Accurate for flow variations 2:1 to 4:1

Parshall Flume:

  • Critical flow section controls velocity
  • Good for wider flow ranges
  • More complex construction

Motorized Gates:

  • Automatic adjustment based on flow measurement
  • Best for very wide flow variations
  • Requires controls and maintenance

Performance Criteria ​

Removal Efficiency ​

Particle SizeSpecific GravityRemoval @ 60s Detention
>0.30mm2.65>99%
0.21mm (design)2.6595%
0.15mm2.6570-80%
0.10mm2.6540-50%
Organics (SG 1.2)1.2<10% (desired)

UK Design Standards ​

ParameterValueStandard
Horizontal velocity0.30 m/sMWH, UK industry practice
Detention time (PHF)45-60sUK industry practice
Water depth1.0-1.5mUK operator
Number of channels≥2All UK water companies
Grit washing<5% organicsEnvironment Agency

Scour Velocity Check ​

To ensure organics remain suspended:

$$v_{scour} = \sqrt{8g \times d_{50} \times \frac{\rho_s - \rho_w}{\rho_w}}$$

For organic particles (d=1mm, SG=1.2): $$v_{scour} \approx 0.45 \text{ m/s}$$

Design velocity (0.30 m/s) < Scour velocity (0.45 m/s) ✓ (organics stay in suspension)

Types of Grit Chambers ​

Horizontal Flow (This Unit) ​

Advantages:

  • Simple, proven design
  • Easy to construct
  • Minimal mechanical equipment
  • Low operating cost

Disadvantages:

  • Larger footprint
  • Velocity control required
  • Grit removal can be manual

Aerated Grit Chamber ​

See Aerated-Grit-Chamber

Differences:

  • Air injection creates spiral flow
  • Better organic separation
  • Self-washing action

Vortex Grit Separator ​

See Vortex-Grit-Separator

Differences:

  • Induced vortex in circular tank
  • Very compact footprint
  • Higher capital cost

Troubleshooting ​

IssueCauseSolution
Excessive organics in gritVelocity too lowIncrease velocity via weir adjustment
Detention time too longReduce length or increase velocity
Grit not washedInstall/improve grit washing
Grit carryover to primaryVelocity too highDecrease velocity (check weir)
Detention time too shortCheck dimensions, verify flow control
High viscosity (cold)Increase detention time for winter
Grit accumulation excessiveGrit removal frequency lowIncrease pumping/removal cycles
Combined sewer eventNormal, increase removal after storm
Odor issuesGrit storage too longMore frequent removal
Organic content highImprove washing, check velocity
Unequal flow distributionSplitter box issueCheck weirs, clean debris
Channel blockageInspect, remove obstruction

Operation & Maintenance ​

Daily Checks ​

  • Visual inspection of flow distribution
  • Check grit removal operation
  • Monitor flow velocity (if instrumented)
  • Observe grit accumulation rate

Weekly Maintenance ​

  • Measure velocity at multiple points (portable meter)
  • Inspect weir condition (algae growth, debris)
  • Check grit washing system
  • Review grit disposal records

Monthly Tasks ​

  • Clean proportional weir
  • Verify detention time calculations
  • Check channel for debris/accumulation
  • Inspect grit removal equipment
  • Test flow splitting between channels

Quarterly Tasks ​

  • Drain channel and clean (one at a time)
  • Measure actual grit depths
  • Inspect structural condition
  • Check for erosion or corrosion
  • Calibrate flow measurement

Annual Tasks ​

  • Performance evaluation (particle size analysis)
  • Verify removal efficiency
  • Update O&M procedures
  • Plan major repairs/upgrades

Grit Handling ​

Grit Washing ​

Purpose: Reduce organic content from ~30% to <5%

Methods:

  • Detritor (cyclone separator + classifier)
  • Grit washer (screw with spray water)
  • Hydrocyclone

Performance:

  • Organic reduction: 80-95%
  • Moisture content: 20-30%
  • Classification: Removes <0.15mm fines

Grit Disposal ​

Disposal MethodRequirementsNotes
LandfillWashed to <5% organicsMost common
Land applicationClean, inertAgricultural use
Construction aggregateWashed, gradedBeneficial reuse
Incineration/WTEIf not washedAvoid if possible (low value)

Grit Production Estimates ​

SourceGrit Yield
Separate sanitary sewer4-15 L/1000m³
Combined sewer (dry weather)10-30 L/1000m³
Combined sewer (wet weather)50-200 L/1000m³
Industrial (food processing)5-30 L/1000m³

Worked Example ​

Given ​

  • Flow: Average 20,000 m³/d, Peak 50,000 m³/d
  • Temperature: 12°C (winter design)
  • Target: Remove 95% of particles >0.21mm (SG 2.65)
  • Two channels for redundancy

Design ​

Step 1: Calculate Settling Velocity at 12°C

Viscosity at 12°C: μ ≈ 0.00124 Pa·s

$$V_s = \frac{9.81 \times (0.00021)^2 \times (2650 - 1000)}{18 \times 0.00124} = 0.0163 \text{ m/s}$$

Step 2: Select Design Parameters

  • Horizontal velocity: v_h = 0.30 m/s
  • Water depth: d = 1.5m
  • Detention time: t = d/V_s = 1.5/0.0163 = 92s ✓ (conservative)

Step 3: Calculate Length $$L = v_h \times t = 0.30 \times 92 = 27.6 \text{ m}$$

Round to L = 28m per channel

Step 4: Determine Width

At peak flow, one channel (allow one offline): $$Q_{peak,single} = \frac{50,000}{24 \times 3600 \times 1} = 0.579 \text{ m}^3/\text{s}$$

$$W = \frac{Q}{v_h \times d} = \frac{0.579}{0.30 \times 1.5} = 1.29 \text{ m}$$

Round to W = 1.5m per channel

Step 5: Verify Surface Loading Rate $$SLR = \frac{Q}{W \times L} = \frac{50,000/24}{1.5 \times 28} = 49.6 \text{ m}^3/\text{m}^2/\text{h}$$

Convert: 49.6 × 20 = 992 m³/m²/d (acceptable for grit chambers)

Step 6: Estimate Grit Production

Assume 10 L/1000m³ for sanitary sewer:

  • Grit volume: 20,000 × 10/1000 = 200 L/d = 0.2 m³/d
  • After washing: ~0.15 m³/d at 25% moisture
  • Mass: 0.15 × 2000 kg/m³ = 300 kg/d

Step 7: Design Weir for Velocity Control

Proportional weir to maintain 0.30 m/s from 50-100% of design flow. Use sutro weir or parabolic weir (design by hydraulic specialist).

Advanced Features ​

Automated Grit Removal ​

  • Continuous screw conveyor
  • Airlift systems
  • Chain and bucket elevators
  • Programmable cycle timing

Flow Measurement and Control ​

  • Ultrasonic flow meters
  • Automated gate control
  • SCADA integration
  • Alarm on velocity deviation

Grit Washing Integration ​

  • Inline grit washer/classifier
  • Continuous organic separation
  • Wash water recirculation

References ​

  1. Metcalf & Eddy (2014). Wastewater Engineering, 5th Ed. McGraw-Hill.
  2. WEF (2018). Design of Municipal Wastewater Treatment Plants, MOP 8.
  3. Camp, T.R. (1946). "Sedimentation and the Design of Settling Tanks." Transactions of ASCE, 111.
  4. Tchobanoglous, G. et al. (2003). Wastewater Engineering: Treatment and Reuse, 4th Ed.
  5. MWH (2005). Water Treatment Principles and Design, 2nd Ed.