Appearance
Tertiary Treatment
Advanced wastewater treatment processes for TSS reduction, disinfection, and dissolved solids removal to meet stringent discharge standards or enable water reuse.
Overview
Tertiary treatment (also called advanced treatment or effluent polishing) follows secondary biological treatment to further improve effluent quality. These processes remove residual suspended solids, pathogens, nutrients, dissolved organics, and in some cases dissolved salts, enabling safe discharge to sensitive receiving waters or water reuse applications.
Process Categories
Filtration
Physical separation processes removing suspended solids and reducing turbidity:
- Rapid-Sand-Filter - Granular sand (0.5-1.0 mm) at 5-15 m/h, TSS to <5 mg/L
- Disk-Filter - Cloth media on rotating disks, 10-20 μm filtration, low footprint
- GAC-Filter - Activated carbon for TSS + dissolved organics, adsorption + filtration
- Anthracite-Filter - Larger media (1.0-2.0 mm) for higher rates, 10-20 m/h
- Dual-Media-Filter - Anthracite + sand stratification, optimized backwash
- Pile-Cloth-Filter - Fabric media on vertical tubes, continuous backwash, compact
Comparison:
| Filter Type | Rate (m/h) | Effluent TSS (mg/L) | Backwash (%) | Application |
|---|---|---|---|---|
| Rapid Sand | 5-15 | 2-5 | 2-4% | Standard tertiary, reliable |
| Disk | 10-25 | 3-8 | 1-3% | Space-constrained, simple O&M |
| GAC | 5-10 | 2-4 | 2-4% | Organics + TSS, micropollutants |
| Anthracite | 10-20 | 3-6 | 2-4% | Higher rates, coarser filtration |
| Dual Media | 10-20 | 2-5 | 3-5% | Optimized performance |
| Pile Cloth | 5-15 | 3-8 | 2-4% | Very compact, continuous operation |
Disinfection
Pathogen inactivation for public health protection:
- UV-Disinfection - UV-C (254 nm) dose 40-100 mJ/cm², no chemicals, Cryptosporidium barrier
- Ozone-Disinfection - O₃ dose 5-15 mg/L, CT 0.5-4 mg·min/L, oxidation + disinfection
- Chlorination - Cl₂ or NaOCl, CT 15-450 mg·min/L, persistent residual, requires dechlorination
- Chlorine-Dioxide - ClO₂, pH-independent, no THMs, chlorite byproduct limits dose
- Peracetic-Acid - CH₃COOOH, 2-8 mg/L, no DBPs, biodegradable to acetic acid
Comparison:
| Disinfectant | Log Reduction (Bacteria) | Cryptosporidium | Residual | DBP Formation | Energy/Chemical Cost |
|---|---|---|---|---|---|
| UV | 4-6 log | 4+ log (best) | No | None | Low energy, no chemicals |
| Ozone | 4-6 log | 2-3 log | No (decays) | Minimal (bromate) | High energy, on-site generation |
| Chlorine | 4-6 log | Poor (<1 log) | Yes (requires dechlorination) | Yes (THMs, HAAs) | Low cost, simple |
| Chlorine Dioxide | 4-6 log | 1-2 log | No | No THMs (chlorite/chlorate) | Moderate, on-site generation |
| Peracetic Acid | 3-5 log | 2-3 log | No | None | High cost, simple dosing |
Membranes
Pressure-driven separation for particle, pathogen, and dissolved solids removal:
- Microfiltration - 0.1-10 μm pores, 0.1-0.5 bar, bacteria/protozoa barrier, RO pretreatment
- Ultrafiltration - 0.01-0.1 μm (10-300 kDa), 0.5-2 bar, virus barrier (4-6 log LRV)
- Nanofiltration - 200-1000 Da, 5-20 bar, hardness/color removal, partial desalination
- Reverse-Osmosis - <100 Da, 10-70 bar, 95-99.5% salt rejection, desalination/reuse
Comparison:
| Membrane | Pore Size | TMP (bar) | Rejection | Recovery (%) | Energy (kWh/m³) | Application |
|---|---|---|---|---|---|---|
| MF | 0.2-0.4 μm | 0.1-0.5 | Particles, bacteria, protozoa | 90-98 | 0.02-0.05 | Tertiary polishing, RO pretreat |
| UF | 0.02-0.1 μm | 0.5-2.0 | + Viruses, macromolecules | 90-98 | 0.05-0.10 | Drinking water, virus barrier |
| NF | 0.5-2 nm | 5-20 | + Divalent ions, color, organics | 70-85 | 0.4-0.8 | Softening, micropollutants |
| RO | <0.001 μm | 10-70 | + Monovalent ions, TDS (95-99%) | 40-85 | 0.5-5.0 | Desalination, water reuse |
Selection Guide
By Effluent Requirement
TSS Removal (<5 mg/L):
- Primary: Rapid Sand Filter, Disk Filter, Dual Media Filter
- Alternative: MF (if virus barrier also needed)
Pathogen Reduction (4-log bacteria):
- Primary: UV, Chlorination (with CT control)
- Alternative: Ozone, PAA, UF
Virus Barrier (4-log LRV):
- Required: UF or UV
- Alternative: Ozone (2-3 log) + UV (additive effect)
Cryptosporidium Barrier:
- Best: UV (4+ log)
- Acceptable: Ozone (2-3 log), UF/MF (physical barrier)
- Ineffective: Chlorine (very high CT required)
Color Removal (>90%):
- Primary: GAC, NF
- Alternative: Ozone (partial)
Hardness Removal (>85%):
- Primary: NF (selective for Ca²⁺, Mg²⁺)
- Alternative: RO (total removal, higher cost)
TDS Removal (>95%):
- Required: RO
- Not suitable: All other processes (no TDS removal)
Micropollutants (pharmaceuticals, pesticides):
- Best: RO (>95% for most), GAC (adsorption, requires regeneration)
- Moderate: NF (60-95%, MW-dependent), Ozone (oxidation, variable)
- Minimal: UV, MF, UF (no removal)
By Application
Discharge to Sensitive River (Urban):
Secondary Effluent → Rapid Sand Filter → UV Disinfection → Discharge
- TSS <5 mg/L (protect UV)
- 4-log pathogen reduction
- No chlorine residual (fish protection)Discharge with Chlorination (Rural, large river):
Secondary Effluent → Disk Filter → Chlorination → Dechlorination → Discharge
- Simple operation
- Persistent residual through contact tank
- Dechlorination to <0.01 mg/LWater Reuse (Non-Potable: Irrigation, Cooling Towers):
Secondary Effluent → Dual Media Filter → UV or Chlorination → Storage
- TSS <5 mg/L (prevent nozzle clogging)
- 4-log pathogen reduction
- Chlorine residual optional (biofilm control in distribution)Water Reuse (Indirect Potable Reuse, IPR):
Secondary Effluent → MF/UF → RO → UV/Chlorine → Aquifer Recharge or Blending
- Multi-barrier: MF/UF (virus) + RO (TDS, organics) + UV (final disinfection)
- Permeate TDS <200 mg/L
- 12+ log virus reduction (combined LRV)Water Reuse (Direct Potable Reuse, DPR):
Secondary Effluent → MF/UF → RO → UV + AOP (H₂O₂) → GAC → Chlorination → Distribution
- Advanced multi-barrier treatment train
- Cryptosporidium, virus, chemical barriers
- Extensive monitoring and fail-safesBrackish Water Desalination:
Brackish Source → Multimedia Filter → Cartridge Filter (5 μm) → RO → Remineralization → Chlorination
- RO for TDS removal (1,500-10,000 mg/L → <250 mg/L)
- Pretreatment critical (SDI <3)
- Post-treatment for water stabilitySeawater Desalination:
Seawater Intake → Dissolved Air Flotation → UF → RO (two-stage) → Remineralization → Chlorination
- Rigorous pretreatment (SDI <2)
- High-pressure RO (55-70 bar)
- Energy recovery essential (ERD, 95% efficiency)By Constraints
Limited Space:
- Disk Filter (most compact filtration)
- MF/UF (vertical configuration, small footprint)
- UV (inline, no contact tank)
Low Energy Budget:
- Rapid Sand Filter + Chlorination (no energy for filtration, low pumping)
- UV (0.02-0.05 kWh/m³)
- MF/UF (0.02-0.10 kWh/m³)
Low Operating Complexity:
- Disk Filter + UV (minimal chemical handling)
- Pile Cloth Filter + UV (continuous operation, automated)
- Chlorination (simple, but requires dechlorination)
No Chemicals Desired:
- UV (no chemicals, no DBPs)
- MF/UF (physical barrier, backwash only)
High Pathogen Removal (>5-log):
- UF + UV (additive: 6 log virus + 4 log UV = 10 log)
- MF + Ozone + UV (multi-barrier)
Design Considerations
Pretreatment Requirements
For Filtration:
- Secondary clarification: TSS <30 mg/L (prevent rapid clogging)
- Flow equalization: Minimize rate variation (extend filter runs)
For Disinfection:
- Turbidity <5 NTU for UV (light transmission, <2 NTU preferred)
- TSS <10 mg/L for chlorine (reduce demand, improve CT)
- Filtration typically required upstream
For Membranes:
- MF/UF: Secondary treatment, minimize TSS and BOD (reduce fouling)
- NF/RO: UF or tight filtration (SDI ❤️), dechlorination (prevent membrane oxidation)
Process Sequencing
Typical sequence (most to least common):
Filtration → Disinfection (80% of plants)
- Filter reduces turbidity for UV or chlorine
- Disinfection as final barrier
Membrane → Disinfection (water reuse, high-quality)
- MF/UF provides pathogen barrier + turbidity reduction
- UV or chlorine as final safety barrier
Disinfection → Filtration (rare, specific cases)
- Pre-chlorination for biofilm control in filter
- Filter removes chlorine demand substances
- Re-disinfection after filtration
Filtration → Membrane → Disinfection (advanced reuse)
- Multimedia filter: Reduce fouling of downstream membrane
- MF/UF or RO: Primary barrier
- UV: Final disinfection
Redundancy and Reliability
Critical systems (no bypass allowed):
- Multiple parallel trains (N+1 or 2N capacity)
- Automated backup (e.g., two UV banks, one duty + one standby)
- Online monitoring with fail-safe shutdown
Example:
Flow = 10,000 m³/d
Design: 4 filter cells × 2,500 m³/d capacity
Operational: 3 cells online, 1 offline for backwash or maintenance
Allows failure of 1 cell and continued operation at 100% capacityTreatment Performance Summary
| Process | TSS Removal | Pathogen Reduction | TDS Removal | Organics Removal | Energy (kWh/m³) | Capital Cost ($/m³/d capacity) |
|---|---|---|---|---|---|---|
| Rapid Sand Filter | >95% (to <5 mg/L) | 1-2 log (protozoa) | None | None | 0.01-0.02 | $50-150 |
| Disk Filter | 90-95% (to <8 mg/L) | 1-2 log | None | None | 0.01-0.02 | $80-200 |
| GAC Filter | >95% (to <5 mg/L) | 1-2 log | None | 50-90% (adsorption) | 0.01-0.02 | $150-300 |
| UV Disinfection | Minimal | 4-6 log (all) | None | Minimal (AOP if H₂O₂ added) | 0.02-0.05 | $100-250 |
| Ozone | Minimal | 4-6 log (bacteria, viruses) | None | 30-70% (oxidation) | 0.10-0.20 | $300-600 |
| Chlorination | Minimal | 4-6 log (bacteria, viruses) | None | None | 0.01-0.02 | $50-150 |
| Microfiltration (MF) | >99% (to <1 mg/L) | 6+ log (bacteria, protozoa) | None | None | 0.02-0.05 | $400-800 |
| Ultrafiltration (UF) | >99% (to <1 mg/L) | 6+ log (all, including viruses) | None | 20-50% (MW >10 kDa) | 0.05-0.10 | $500-1,000 |
| Nanofiltration (NF) | >99% | 6+ log | 40-80% (selective) | 60-95% | 0.40-0.80 | $800-1,500 |
| Reverse Osmosis (RO) | >99.9% | 6+ log | 95-99.5% | 95-99% | 0.5-5.0 | $1,000-3,000 |
Notes:
- Capital costs are approximate installed cost per m³/d of capacity (2024)
- Energy values include process only, not upstream pumping
- Operating costs vary widely based on local chemical/energy prices
Process Unit Links
Filtration
Disinfection
Membranes
Related Processes
- Secondary-Clarifier - Upstream clarification
- Chemical-Dosing - Coagulation, antiscalant, disinfectant feed
- Nutrient-Removal - Nitrogen and phosphorus removal
- Sludge-Handling - Backwash waste, concentrate disposal
References
- WEF (2018). Design of Municipal Wastewater Treatment Plants, MOP 8, 6th Ed., Vol. 3: Tertiary Treatment.
- Metcalf & Eddy (2014). Wastewater Engineering: Treatment and Resource Recovery, 5th Ed., McGraw-Hill, Ch. 10-11.
- AWWA (2011). Water Quality and Treatment: A Handbook on Drinking Water, 6th Ed., McGraw-Hill.
- Crittenden, J.C. et al. (2012). MWH's Water Treatment: Principles and Design, 3rd Ed., Wiley.
- US EPA (2012). Guidelines for Water Reuse, EPA/600/R-12/618.
- WHO (2017). Potable Reuse: Guidance for Producing Safe Drinking-Water, World Health Organization.
- Tchobanoglous, G. et al. (2015). Decentralized Wastewater Management, Water Environment Federation.