Skip to content

HPO - High Purity Oxygen Activated Sludge ​

High-rate activated sludge process using pure oxygen (90-99.5% O2) in covered tanks for enhanced oxygen transfer and intensified biological treatment.

Overview ​

High Purity Oxygen (HPO) activated sludge, also known as pure oxygen activated sludge, uses enriched oxygen (typically >90% O2) instead of air for aeration. The process operates in covered, staged reactors that maintain high dissolved oxygen levels (8-25 mg/L), enabling significantly higher organic loading rates and shorter detention times compared to conventional air-based systems.

When to Use ​

  • Industrial wastewater with high organic loads
  • Space-constrained sites requiring compact treatment
  • Retrofitting overloaded conventional plants
  • High-strength wastewaters (>500 mg BOD/L)
  • Pulp and paper, refinery, food processing
  • Plants with on-site oxygen availability
  • Cold climate applications (enclosed system)

Key Characteristics ​

  • 3-5x higher oxygen transfer rates than air
  • 50-75% smaller tank volumes than conventional
  • Higher MLSS concentrations (4,000-10,000 mg/L)
  • Covered tanks with gas recirculation
  • Superior oxygen utilization (85-95%)
  • Consistent effluent quality
  • Reduced off-gas and odor emissions

Oxygen Transfer Theory ​

Oxygen Solubility Enhancement ​

Henry's Law for oxygen: $$C_s^* = H \times p_{O2}$$

Where:

  • C_s* = saturation concentration (mg/L)
  • H = Henry's constant (mg/L/atm)
  • p_O2 = oxygen partial pressure (atm)

For pure O2 vs air:

  • Air: p_O2 = 0.21 atm, C_s* = 9.2 mg/L (at 20 deg C)
  • Pure O2: p_O2 = 1.0 atm, C_s* = 44 mg/L (at 20 deg C)

Saturation increase: 4.8x

Oxygen Transfer Rate ​

$$OTR = K_La \times (C_s^* - C)$$

Where:

  • OTR = oxygen transfer rate (kg O2/m3/h)
  • K_La = volumetric mass transfer coefficient (1/h)
  • C = bulk DO concentration (mg/L)

Driving Force Enhancement ​

For air at C = 2 mg/L: $$\Delta C_{air} = 9.2 - 2 = 7.2 \text{ mg/L}$$

For pure O2 at C = 8 mg/L: $$\Delta C_{HPO} = 44 - 8 = 36 \text{ mg/L}$$

Driving force increase: 5x

Alpha Factor Considerations ​

$$\alpha = \frac{K_La \text{ (wastewater)}}{K_La \text{ (clean water)}}$$

HPO systems typically achieve higher alpha (0.6-0.9) due to:

  • Enclosed headspace reducing surfactant effects
  • Higher bubble residence time
  • Better mixing conditions

Process Configuration ​

Covered Reactor System ​

        Gas Recirculation
         ←─────────────────────────────┐
         │                             │
    ┌────┴────┐  ┌────────┐  ┌────────┐  ┌────┴────┐
    │ Stage 1 │→ │ Stage 2│→ │ Stage 3│→ │ Stage 4│→ To Clarifier
    │         │  │        │  │        │  │         │
    └────┬────┘  └───┬────┘  └────┬───┘  └────┬────┘
         │           │            │           │
    O2 Feed      Surface       Surface     Exhaust
                 Aerators      Aerators     Gas

Staging Benefits ​

Multiple stages in series provide:

  • Plug-flow hydraulics for better kinetics
  • Oxygen gradient (higher at inlet)
  • Efficient oxygen utilization
  • Process flexibility

Typical: 3-4 stages

Gas-Liquid Contact ​

EquipmentDescriptionOxygen Utilization
Surface aeratorsCovered mechanical mixers80-90%
Submerged turbinesSparged + mixing85-95%
Jet aeratorsHigh-velocity injection90-95%
Hollow fiberMembrane dissolution>95%

Design Equations ​

Oxygen Requirement ​

$$OR = \frac{Q \times \Delta S}{Y_{obs}} + 4.57 \times Q \times \Delta N - 2.86 \times Q \times N_{denit}$$

Where:

  • OR = oxygen requirement (kg O2/d)
  • Delta S = BOD removed (mg/L)
  • Y_obs = observed yield (kg cells/kg BOD)
  • Delta N = nitrogen nitrified (mg/L)
  • N_denit = nitrogen denitrified (mg/L)

Aeration Tank Volume ​

$$V = \frac{Q \times S_0 \times \theta_c \times Y}{X \times (1 + k_d \times \theta_c)}$$

HPO allows 50-75% volume reduction vs air systems.

F:M Ratio ​

$$F:M = \frac{Q \times S_0}{V \times X}$$

HPO typical: 0.4-1.5 kg BOD/kg MLSS/d (vs 0.2-0.6 conventional)

Sludge Retention Time ​

$$\theta_c = \frac{V \times X}{Q_w \times X_w + Q_e \times X_e}$$

HPO typical: 1-4 days (vs 5-15 conventional)

Oxygen Utilization Efficiency ​

$$OUE = \frac{OR}{O2_{feed}} \times 100%$$

Target: 85-95%

Gas Purity Maintenance ​

$$\frac{dC_{O2}}{dt} = \frac{O2_{feed} - OR - O2_{exhaust}}{V_{headspace}}$$

Maintain >85% O2 in headspace

Design Criteria ​

Loading Rates ​

ParameterHPOConventionalUnits
F:M0.4-1.50.2-0.6kg BOD/kg/d
Volumetric load1.5-4.00.5-1.2kg BOD/m3/d
MLSS4,000-10,0002,000-4,000mg/L
HRT1-34-8hours
SRT1-45-15days

Oxygen System Design ​

ParameterDesign ValueRangeUnits
O2 purity9390-99.5%
DO setpoint8-126-25mg/L
Gas space O285-9580-98%
Vent rate5-15-% of feed
O2 utilization9085-95%

Reactor Configuration ​

ParameterDesign ValueRange
Number of stages43-6
L:W ratio2:11:1-3:1
Depth4.5-64-8 m
Freeboard (gas)0.3-0.50.2-1.0 m
Cover materialFRP/concrete-

Parameters ​

Reactor Parameters ​

ParameterUnitDefaultRangeDescription
Volumem3calculated-Total reactor
Stages-43-6Number of stages
Stage volume ratio-equal1:1-2:1First to last
Depthm54-8Liquid depth
Cover type-FRPFRP/concreteMaterial
Headspacem0.40.2-0.6Gas zone

Biological Parameters ​

ParameterUnitDefaultRangeDescription
MLSSmg/L60004000-10000Mixed liquor
F:Mkg/kg/d0.80.4-1.5Food to micro
SRTd21-4Solids retention
Yieldkg/kg0.50.4-0.6Observed yield
k_d1/d0.060.04-0.08Decay rate

Oxygen System Parameters ​

ParameterUnitDefaultRangeDescription
O2 purity%9390-99.5Feed oxygen
O2 feed ratekg/dcalculated-Oxygen supply
DO setpointmg/L106-25Per stage
Gas recirculation%2010-40Of headspace
Vent rate%105-20CO2 purge
OUE target%9085-95Utilization

Aeration Equipment ​

ParameterUnitDefaultRangeDescription
Aerator type-surfaceAeratorsurface/submergedEquipment
PowerW/m33020-50Mixing power
Speedrpm6040-100Rotational
Immersion%5030-70Depth fraction

Oxygen Supply Systems ​

On-Site Generation ​

TechnologyPurityCapacityApplication
PSA90-95%20-200 t/dMedium plants
VSA90-93%50-500 t/dLarge plants
Cryogenic99.5%>100 t/dVery large
Membrane30-50%SmallOxygen enrichment

Delivered Liquid Oxygen (LOX) ​

  • Purity: 99.5%
  • Storage: Cryogenic tanks
  • Vaporizers required
  • Suitable for: Small plants, backup

Cost Comparison ​

MethodCapitalO2 CostBest Application
LOXLowHigh<5 t/d
PSAMediumMedium5-50 t/d
VSAHighLow>50 t/d
CryogenicVery highVery low>200 t/d

Configuration ​

Example Configuration ​

json
{
  "type": "hpo",
  "id": "hpo-industrial-treatment",
  "parameters": {
    "reactor": {
      "totalVolume": 2000,
      "stages": 4,
      "stageConfiguration": "equal",
      "dimensions": {
        "length": 20,
        "width": 10,
        "liquidDepth": 5,
        "headspace": 0.4
      },
      "cover": {
        "material": "FRP",
        "gasSealing": "pressurized"
      }
    },
    "biological": {
      "mlss": 6000,
      "fm": 0.8,
      "srt": 2.5,
      "temperature": 25
    },
    "oxygenSystem": {
      "supplyType": "PSA",
      "purity": 93,
      "feedRate": 2500,
      "doSetpoints": [15, 12, 10, 8],
      "headspaceO2": 90,
      "ventRate": 12,
      "oueTarget": 90
    },
    "aeration": {
      "type": "coveredSurfaceAerator",
      "unitsPerStage": 2,
      "powerPerUnit": 75,
      "speed": 60,
      "immersion": 0.5
    },
    "safetyFeatures": {
      "o2Monitors": true,
      "explosionVents": true,
      "coMonitor": true,
      "purgeSystem": "nitrogen"
    }
  }
}

Worked Example ​

Given ​

  • Industrial wastewater flow: 15,000 m3/d
  • Influent BOD: 800 mg/L
  • Influent TSS: 400 mg/L (after primary)
  • Target: BOD <30 mg/L
  • Temperature: 25 deg C
  • Space constraint: Max 600 m2 footprint

Design ​

Step 1: BOD Load $$L_{BOD} = 15,000 \times 0.8 = 12,000 \text{ kg BOD/d}$$

Step 2: Oxygen Requirement Assuming Y_obs = 0.5 kg VSS/kg BOD, carbonaceous only:

$$OR = \frac{12,000}{0.5} \times 1.42 + 12,000 \times 0.1 = 17,040 + 1,200 = 18,240 \text{ kg O}_2\text{/d}$$

Wait - let me recalculate properly: O2 for synthesis: 12,000 x (1 - 1.42 x 0.5) = 12,000 x 0.29 = 3,480 kg/d O2 for endogenous: Estimate 30% of synthesis = 1,044 kg/d

Actually, simpler approach: O2 = 1.1-1.4 x BOD removed = 1.2 x 12,000 = 14,400 kg O2/d

Step 3: HPO Reactor Volume

Using volumetric loading = 2.5 kg BOD/m3/d: $$V = \frac{12,000}{2.5} = 4,800 \text{ m}^3$$

Hmm, that's large. Let's use higher loading (3.5 kg/m3/d for HPO): $$V = \frac{12,000}{3.5} = 3,430 \text{ m}^3$$

Step 4: Dimensions Check At depth 6m: $$A = 3,430/6 = 572 \text{ m}^2$$ < 600 m2 constraint

4 stages: Each 143 m2, dimension 12m x 12m x 6m

Step 5: MLSS and SRT F:M = 0.8 kg BOD/kg MLSS/d

$$MLSS = \frac{Q \times S_0}{V \times F:M} = \frac{15,000 \times 0.8}{3,430 \times 0.8} = 4,370 \text{ mg/L}$$

Round to 4,500 mg/L (conservative)

HRT = 3,430 / (15,000/24) = 5.5 hours

SRT = V x MLSS / (waste sludge) Estimate SRT = 2-3 days for HPO

Step 6: Oxygen System Sizing

O2 requirement = 14,400 kg/d At 90% OUE: $$O2_{feed} = \frac{14,400}{0.90} = 16,000 \text{ kg O}_2\text{/d} = 667 \text{ kg/h}$$

PSA system at 93% purity: Capacity required = 16,000 / 0.93 = 17,200 kg O2 product/d = 17.2 t/d

Step 7: Vent Gas Calculation

CO2 production approx 0.9 x O2 consumption = 0.9 x 14,400 = 12,960 kg CO2/d

To maintain 90% O2 in headspace: Vent rate = 10% of feed = 1,600 kg/d (carries CO2 + some O2)

Step 8: Aeration Power

Surface aerators at 30 W/m3: $$P_{total} = 30 \times 3,430 = 103 \text{ kW}$$

Plus PSA power (approx 0.3 kWh/kg O2): $$P_{PSA} = 0.3 \times 667 = 200 \text{ kW}$$

Step 9: Comparison with Conventional

Conventional AS for same load:

  • Volume: 12,000 / 0.8 = 15,000 m3 (4.4x larger)
  • Area at 5m: 3,000 m2 (5.2x larger)
  • Aeration: 0.8 kWh/kg O2 x 14,400/24 = 480 kW

HPO savings:

  • Volume: 77% reduction
  • Area: 81% reduction
  • Power: Similar (303 vs 480 kW) but 37% lower

Step 10: Summary

ParameterValueUnits
Reactor volume3,430m3
Footprint572m2
Number of stages4-
MLSS4,500mg/L
HRT5.5hours
O2 feed rate16,000kg/d
PSA capacity17.2t/d
Total power303kW

Safety Considerations ​

Oxygen-Enriched Atmosphere Hazards ​

HazardRisk LevelMitigation
Fire/explosionHighO2 monitors, vent systems
Oxidizer contactMediumMaterial selection
AsphyxiationLowConfined space procedures
Pressure buildupMediumRelief valves

Design Safety Features ​

  1. Continuous O2 monitoring in headspace
  2. CO detector for incomplete combustion
  3. Explosion relief panels or vents
  4. Nitrogen purge system for maintenance
  5. Flame arrestors on vents
  6. Earthing/grounding of all equipment
  7. Oil-free components in O2 contact areas

Material Compatibility ​

ComponentAcceptable Materials
PipingStainless steel, copper
SealsViton, PTFE, silicone
LubricantsO2-compatible only
CoatingsEpoxy (O2-rated)
AvoidCarbon steel, oils, greases

Operational Protocols ​

  • Maintain headspace O2 <95% (fire risk increases sharply above)
  • Regular leak testing
  • Hot work permits
  • Confined space entry procedures
  • Emergency vent procedures

Troubleshooting ​

IssueCauseSolution
Low DO in final stageInsufficient O2 feedIncrease oxygen
OverloadingReduce flow, add stage
Poor OUEGas leakageCheck seals, covers
High vent rateReduce, check CO2
Poor mixingIncrease aerator speed
High effluent BODShort SRTReduce wasting
OverloadingIncrease volume, O2
FoamingLow MLSSIncrease SRT
SurfactantsSource control
Poor settlingLow SRTIncrease
FilamentsSelector, chlorination
Rising CO2MetabolismIncrease vent rate
Poor strippingCheck aerators
Headspace O2 dropHigh loadIncrease O2 feed
System leakPressurize, find leak

Commercial Technologies ​

TechnologyManufacturerFeatures
UNOXLindeOriginal HPO system
OACESAir ProductsStaged system
MAROXUnion CarbideSurface aerators
Bio-OxygenFMCJet aeration

Advantages and Limitations ​

Advantages ​

  1. Compact: 50-75% smaller footprint
  2. High rate: 3-5x conventional loading
  3. Stable: Consistent DO, enclosed system
  4. Odor control: Covered reactors
  5. Cold climate: Enclosed, heated if needed
  6. Retrofit: Upgrades overloaded plants

Limitations ​

  1. Capital cost: Oxygen system expensive
  2. Operating cost: Oxygen production energy
  3. Complexity: More sophisticated operation
  4. Safety: Oxygen-enriched atmosphere risks
  5. Nitrification: May be limited at short SRT
  6. Maintenance: Covers, seals, oxygen equipment
  • CSTR - Conventional Activated Sludge
  • High-Rate-Activated-Sludge - Air-based high rate
  • Oxygen-Transfer - Aeration fundamentals
  • Industrial-Wastewater - High-strength treatment
  • Cryogenic-Oxygen - Oxygen production

References ​

  1. EPA (1977). Process Design Manual for High Purity Oxygen Activated Sludge.
  2. Metcalf & Eddy (2014). Wastewater Engineering: Treatment and Resource Recovery. 5th Ed.
  3. WEF/ASCE (2018). Design of Municipal Wastewater Treatment Plants, MOP 8.
  4. Albertson, O.E. & DiGregorio, D. (1975). "Pure oxygen activated sludge". Journal WPCF.
  5. Air Products (2010). OACES System Design Manual.
  6. Daigger, G.T. & Littleton, H.X. (2014). "Simultaneous biological nutrient removal: A state-of-the-art review". Water Environment Research.