Skip to content

Membrane Filtration ​

Pressure-driven separation processes using semi-permeable membranes for particle, pathogen, and dissolved solids removal across the spectrum from microfiltration to reverse osmosis.

Overview ​

Membrane processes provide absolute barriers to contaminants based on size exclusion and, in some cases, charge-based (Donnan) exclusion. Ranging from microfiltration (bacteria/protozoa removal) to reverse osmosis (desalination), membranes enable advanced water treatment including drinking water production, water reuse, and industrial process water applications.

Membrane Hierarchy ​

Membranes are classified by pore size, operating pressure, and rejection characteristics:

Coarse → Fine                                        Low Pressure → High Pressure
┌─────────────┬──────────────┬──────────────┬─────────────────┐
│     MF      │      UF      │      NF      │       RO        │
├─────────────┼──────────────┼──────────────┼─────────────────┤
│ 0.1-10 μm   │ 0.01-0.1 μm  │  0.5-2 nm    │   <0.001 μm     │
│             │  (10-300 kDa)│ (200-1000 Da)│    (<100 Da)    │
├─────────────┼──────────────┼──────────────┼─────────────────┤
│ 0.1-0.5 bar │  0.5-2 bar   │   5-20 bar   │   10-70 bar     │
├─────────────┼──────────────┼──────────────┼─────────────────┤
│ Size only   │  Size only   │ Size + charge│  Solution-      │
│             │              │              │  diffusion      │
└─────────────┴──────────────┴──────────────┴─────────────────┘

Rejection:
Particles       ████████████████████████████████████████████
Bacteria        ████████████████████████████████████████████
Protozoa        ████████████████████████████████████████████
Viruses         ░░░░░░░░░░░░░███████████████████████████████
Macromolecules  ░░░░░░░░░░░░░░░░░░░░░███████████████████████
Divalent ions   ░░░░░░░░░░░░░░░░░░░░░░░░░░░░░███████████████
Monovalent ions ░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░████████
TDS             ░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░████

Legend: ████ = Rejected (>90%)  ░░░░ = Passes through (<10% rejection)

Available Membrane Technologies ​

Microfiltration ​

Particle and bacteria barrier

  • Pore size: 0.1-10 μm (typically 0.2-0.4 μm)
  • Operating pressure: 0.1-0.5 bar (very low)
  • Permeate flux: 50-150 LMH
  • Recovery: 90-98%

Rejection:

  • Particles, bacteria, protozoa: >99.9% (4-6 log validated)
  • Viruses: 0-2 log (unreliable, size-dependent)
  • Dissolved solids (TDS): None (0%)
  • Macromolecules: Minimal (large molecules only)

Applications:

  • Tertiary polishing (TSS <1 mg/L, turbidity <0.1 NTU)
  • RO pretreatment (reduce fouling potential, SDI ❤️)
  • Giardia/Cryptosporidium barrier (absolute, >4 log)
  • MBR (membrane bioreactor) configuration

Best for:

  • TSS removal without virus requirement
  • RO pretreatment (superior to conventional filtration)
  • Lowest energy membrane option (0.02-0.05 kWh/m³)

Ultrafiltration ​

Virus barrier

  • Pore size: 0.01-0.1 μm (10-100 nm) or MWCO 10-300 kDa
  • Operating pressure: 0.5-2 bar
  • Permeate flux: 30-100 LMH
  • Recovery: 90-98%

Rejection:

  • Particles, bacteria, protozoa: >99.9% (6+ log validated)
  • Viruses: 4-6 log (validated LRV, absolute barrier)
  • Dissolved organics: 20-50% (macromolecules >MWCO only)
  • TDS: None (0%)

Applications:

  • Drinking water (virus barrier, 4-log minimum)
  • Direct/indirect potable reuse (multi-barrier treatment)
  • RO pretreatment (superior to MF for high-fouling feeds)
  • Color removal (partial, humic/fulvic acids)

Best for:

  • Virus barrier required (drinking water, reuse)
  • Tight pretreatment for RO/NF
  • Energy: 0.05-0.10 kWh/m³ (still low compared to NF/RO)

Nanofiltration ​

Softening and partial desalination

  • Pore size: 0.5-2 nm (MWCO 200-1000 Da, typically 300-400 Da)
  • Operating pressure: 5-20 bar
  • Permeate flux: 15-50 LMH
  • Recovery: 70-85%

Rejection:

  • Particles, bacteria, viruses, protozoa: >99.9% (6+ log)
  • Divalent ions (Ca²⁺, Mg²⁺, SO₄²⁻): 85-98%
  • Monovalent ions (Na⁺, Cl⁻): 20-70%
  • Organic molecules (>300 Da): 90-99%
  • TDS: 40-80% (partial desalination)

Mechanism: Size exclusion + Donnan (charge) exclusion

Applications:

  • Water softening (hardness removal without salt)
  • Color removal (humic/fulvic acids, 90-99%)
  • Micropollutant removal (pharmaceuticals, pesticides, 60-95%)
  • Partial desalination (brackish water, TDS 1,000-5,000 mg/L)
  • RO pretreatment (reduce scaling potential, higher RO recovery)

Best for:

  • Hardness removal (Ca²⁺/Mg²⁺) without full desalination
  • Moderate TDS reduction at lower pressure than RO
  • Micropollutant removal (water reuse)

Reverse-Osmosis ​

Desalination and ultrapure water

  • Pore size: <0.001 μm (<1 nm, molecular-scale)
  • Operating pressure: 10-25 bar (brackish), 55-70 bar (seawater)
  • Permeate flux: 15-25 LMH (brackish), 10-15 LMH (seawater)
  • Recovery: 75-85% (brackish), 40-50% (seawater)

Rejection:

  • All particles, pathogens: >99.9% (essentially 100%)
  • Divalent ions: 99-99.9%
  • Monovalent ions: 95-99.5% (brackish), 99-99.7% (seawater)
  • Organics: 95-99%
  • TDS: 95-99.5%

Mechanism: Solution-diffusion (water permeates, salts rejected)

Applications:

  • Seawater desalination (TDS 35,000 mg/L → <500 mg/L)
  • Brackish water desalination (TDS 1,500-10,000 mg/L → <250 mg/L)
  • Direct/indirect potable reuse (wastewater → drinking water)
  • Ultrapure water (pharmaceutical, electronics, power generation)
  • Industrial process water (boiler feed, manufacturing)
  • Zero liquid discharge (ZLD) concentration step

Best for:

  • High TDS removal (>95%)
  • Drinking water from saline sources
  • Water reuse requiring very low TDS

Technology Comparison ​

MembranePore SizePressure (bar)Flux (LMH)Energy (kWh/m³)Virus RemovalTDS RemovalCapital Cost ($/m³/d)Application
MF0.2-0.4 μm0.1-0.550-1500.02-0.050-2 logNone$400-800TSS, RO pretreat
UF0.02-0.1 μm0.5-2.030-1000.05-0.104-6 log ✓None$500-1,000Drinking water, virus barrier
NF0.5-2 nm5-2015-500.40-0.806+ log40-80%$800-1,500Softening, micropollutants
RO<1 nm10-7010-250.5-5.06+ log95-99.5% ✓$1,000-3,000Desalination, reuse

Energy notes:

  • MF/UF: Very low energy (low pressure)
  • NF: Moderate energy (medium pressure)
  • RO: Higher energy, but with ERD (energy recovery device): Brackish 0.5-1.5 kWh/m³, Seawater 3-5 kWh/m³

Selection Guide ​

By Water Quality Goal ​

TSS Removal (<1 mg/L):

  • Primary: MF or UF (both achieve <1 mg/L easily)
  • Selection: MF if no virus requirement (lower cost/energy), UF if virus barrier also needed

Virus Barrier (4-log LRV):

  • Required: UF (validated 4-6 log LRV)
  • Alternative: MF is NOT reliable for viruses
  • Note: RO/NF also remove viruses, but typically used for other purposes (TDS, etc.)

Cryptosporidium Barrier:

  • All membranes (MF/UF/NF/RO) provide absolute barrier (>4 log)
  • MF is sufficient and most economical if only protozoa concern

Hardness Removal (>85% Ca²⁺/Mg²⁺):

  • Primary: NF (selective for divalent ions, 85-98% removal)
  • Alternative: RO (100% removal, but higher energy/cost)

TDS Removal (>95%):

  • Required: RO (only option for high TDS removal)
  • NF insufficient (40-80% TDS removal only)

Micropollutants (pharmaceuticals, pesticides):

  • Best: RO (>95% removal for most compounds)
  • Moderate: NF (60-95%, molecular weight dependent)
  • Poor: MF/UF (minimal removal, only very large molecules)

Color Removal:

  • Best: RO (>95%), NF (90-95%)
  • Moderate: UF (20-50%, macromolecules only)
  • Poor: MF (minimal, <10%)

By Application ​

Tertiary TSS Removal (discharge compliance):

Secondary Effluent (TSS 10-20 mg/L) → MF → TSS <1 mg/L, Turbidity <0.1 NTU
- MF sufficient (lowest cost membrane option)
- No virus barrier needed (discharge, not reuse)
- Energy: 0.02-0.05 kWh/m³ (very low)

RO Pretreatment (reduce fouling):

Brackish Water → MF or UF → RO → Potable Water
- MF typically sufficient (TSS, SDI reduction)
- UF if feed water has high organic/biological fouling potential
- Protects RO from particulate fouling, extends membrane life

Drinking Water (surface water):

Filtered Surface Water → UF → Chlorination → Distribution
- UF for 4-log virus removal (regulatory compliance)
- Lower cost than RO (no TDS removal needed)
- Energy: 0.05-0.10 kWh/m³

Indirect Potable Reuse (IPR):

Secondary Effluent → MF/UF → RO → UV/Chlorine → Aquifer or Reservoir
- MF/UF: Virus barrier + RO pretreatment (SDI <2)
- RO: TDS removal, organics removal, additional pathogen barrier
- UV/Chlorine: Final disinfection
- Multi-barrier: >12 log virus reduction (regulatory compliance)

Direct Potable Reuse (DPR):

Secondary Effluent → UF → RO → UV-AOP → GAC → Chlorination → Distribution
- Extreme multi-barrier treatment
- UF: 6 log virus, pretreatment
- RO: TDS, organics, 6 log virus (additive)
- UV-AOP: Advanced oxidation (trace organics, 4 log virus)
- GAC: Polishing (organics adsorption)
- Total: >12 log virus, >10 log Crypto

Water Softening:

Brackish Water (Hardness 200-400 mg/L) → NF → Softened Water (Hardness <50 mg/L)
- NF removes 85-98% hardness (Ca²⁺, Mg²⁺)
- Lower energy than RO (5-15 bar vs. 15-25 bar)
- Partial TDS removal (bonus, 40-80%)

Seawater Desalination:

Seawater (TDS 35,000 mg/L) → DAF → UF → RO (two-stage) → Remineralization → Chlorination
- UF: Critical pretreatment (SDI <2, rigorous)
- RO: Two-stage with interstage booster pump (high recovery)
- Energy recovery essential (ERD, 95% efficiency)
- Final TDS <500 mg/L (potable water standard)
- Energy: 3-5 kWh/m³ (state-of-the-art with ERD)

Brackish Water Desalination:

Brackish Source (TDS 2,000-5,000 mg/L) → Multimedia Filter → Cartridge Filter → RO → Remineralization
- Conventional pretreatment acceptable (multimedia or MF)
- Single-stage RO (lower pressure than seawater)
- Recovery: 75-85%
- Energy: 0.5-1.5 kWh/m³ (with ERD)

Zero Liquid Discharge (ZLD):

RO Concentrate → Additional RO → Brine Concentrator → Crystallizer → Solid Salts
- Multiple RO passes to maximize recovery (90-95%)
- Thermal evaporation (brine concentrator) for final concentration
- Crystallizer for solid salt production
- Achieve zero liquid discharge (all water recovered or evaporated)

By Constraint ​

Limited Energy Budget:

  1. MF (0.02-0.05 kWh/m³, lowest)
  2. UF (0.05-0.10 kWh/m³)
  3. Avoid: RO (0.5-5.0 kWh/m³, high)

Limited Space:

  • All membranes are compact (vertical configuration, small footprint)
  • MF/UF: Slightly larger membrane area (higher flux)
  • NF/RO: Smaller area (lower flux), but higher pressure equipment

Low Operating Complexity:

  1. MF (simple backwash, minimal chemicals)
  2. UF (similar to MF, automated)
  3. Avoid: RO (scaling management, antiscalant, CIP, concentrate disposal)

High Fouling Feed (poor pretreatment):

  1. UF (better tolerance than MF, smaller pores resist internal fouling)
  2. MF (acceptable if good pretreatment impossible)
  3. Avoid: NF/RO (very sensitive, require excellent pretreatment)

Common Design Features ​

Membrane Configurations ​

Hollow Fiber (HF):

  • Most common for MF/UF
  • High packing density (>10,000 m²/m³)
  • Inside-out or outside-in flow
  • Backwashable
  • Area per module: 30-60 m² (MF), 40-80 m² (UF)

Spiral Wound:

  • Standard for NF/RO
  • Moderate packing density (~800 m²/m³)
  • Feed flows axially, permeate spirals to center tube
  • Not backwashable (CIP only)
  • Standard element: 8"×40", 37 m² (NF/RO)

Flat Sheet:

  • Less common, some MF/UF applications
  • Easy to clean, low fouling
  • Lower packing density
  • Used in MBR (submerged configuration)

Tubular:

  • Rare, high-cost
  • Very low fouling (large diameter, 5-25 mm)
  • Easy mechanical cleaning
  • Industrial applications (food processing, high-solids)

Operating Modes ​

Dead-End Filtration (MF/UF):

  • All feed becomes permeate (no concentrate stream during filtration)
  • Solids accumulate on membrane (cake layer)
  • Periodic backwash removes cake
  • Recovery: 90-98% (accounting for backwash)

Crossflow Filtration (NF/RO):

  • Continuous concentrate stream (tangential flow)
  • High crossflow velocity sweeps membrane surface (reduces concentration polarization)
  • No backwash (CIP only)
  • Recovery: 40-85% (depending on feed TDS, scaling potential)

Fouling Control ​

Backwash (MF/UF only):

  • Frequency: 15-60 minutes
  • Duration: 30-90 seconds
  • Reverse flux: 150-250 LMH (higher than forward flux)
  • Removes cake layer, restores 80-95% of flux

CEB - Chemically Enhanced Backwash (MF/UF):

  • Frequency: Daily (every 12-48 backwash cycles)
  • Chemicals: NaOCl (50-200 ppm) for organics/biofilm, citric acid (1000-2000 ppm) for scaling
  • Contact time: 5-10 minutes
  • Restores flux between CIP intervals

CIP - Clean-In-Place (all membranes):

  • Frequency: Monthly to quarterly (MF/UF), 3-6 months (NF/RO)
  • Chemicals:
    • Caustic (NaOH 0.1-0.5%) + Surfactant: Organic fouling
    • Acid (HCl or citric acid 1-2%): Mineral scaling
    • Oxidizer (NaOCl 500-1000 ppm): Biological fouling
  • Procedure: Recirculation (not backwash), 1-4 hour soak
  • Target: >90% flux recovery

Antiscalant (NF/RO only):

  • Dose: 2-10 mg/L (feed water)
  • Purpose: Prevent CaCO₃, CaSO₄, BaSO₄, silica precipitation
  • Allows higher recovery (typical: 75-85% vs. 60-70% without)
  • Annual cost: $50,000-200,000 for large plants

Pretreatment Requirements ​

MembraneSDI RequirementTurbidityTSSDechlorinationScaling Control
MFN/A (pretreat)<30 NTU<50 mg/LNot criticalNot needed
UFN/A (pretreat)<30 NTU<50 mg/LNot criticalNot needed
NF❤️ (preferably <2)<1 NTU<5 mg/LRequired (<0.1 mg/L free Cl₂)Antiscalant required
RO❤️ (preferably <2)<1 NTU<5 mg/LCritical (<0.05 mg/L free Cl₂)Antiscalant + pH control

Pretreatment sequence for RO:

Raw Water → Coagulation/Flocculation → Sedimentation → Multimedia Filter → Cartridge Filter (5 μm) → Dechlorination → RO

OR (better):

Raw Water → UF → Cartridge Filter (security) → Dechlorination → RO

Performance Monitoring ​

Normalized Parameters ​

Why normalize: Flux and salt passage vary with temperature, pressure, and feed concentration. Normalization allows comparison to baseline.

Normalized Permeate Flow (NPF):

$$NPF = \frac{Q_{permeate,actual} \times TCF}{\Delta P_{actual} / \Delta P_{design}}$$

Where $TCF$ = temperature correction factor (e.g., 1.03^(T-25))

Normalized Salt Passage (NSP):

$$NSP = \frac{(C_p / C_f){actual}}{(C_p / C_f){design}} \times \frac{TCF_{design}}{TCF_{actual}}$$

Action triggers:

  • NPF decline >10-15%: Plan CIP
  • NSP increase >10%: Investigate membrane damage or seal leak
  • Differential pressure increase >15%: Fouling, CIP required

Integrity Testing ​

Pressure Decay Test (MF/UF, offline):

  • Pressurize membrane (0.5-2 bar, below operating pressure)
  • Isolate and monitor pressure decay
  • Acceptance: ❤️-5 mbar/min (indicates no fiber breaks or seal leaks)

Bubble Point Test (offline):

  • Detect largest pore size (fiber break detection)
  • Air pressure gradually increased until bubbles appear in permeate
  • Compare to specification (should exceed design pore size)

Online Monitoring:

  • Permeate turbidity: Continuous monitoring, alarm at 0.1 NTU (MF) or 0.05 NTU (UF)
  • Particle counting: >2 μm particles in permeate, alarm at >10 counts/mL
  • LRV challenge testing: Periodic (virus surrogate spiking for UF)

Advanced Membrane Systems ​

Two-Pass RO (Ultrapure Water) ​

Configuration:

  • Pass 1: Standard BWRO (TDS 1,000-5,000 mg/L → 20-100 mg/L)
  • Pass 2: Polish RO (TDS 20-100 mg/L → <1 mg/L)

Applications:

  • Pharmaceutical water (USP Purified Water)
  • Semiconductor manufacturing (resistivity >15 MΩ·cm)
  • Power plant boiler feed (prevent scaling/corrosion)

Membrane Bioreactor (MBR) ​

Configuration:

  • Submerged hollow fiber MF/UF membranes in activated sludge basin
  • Replaces secondary clarifier
  • Operates at very low flux: 15-30 LMH (high MLSS, 8,000-12,000 mg/L)

Advantages:

  • Absolute solid-liquid separation (TSS <1 mg/L)
  • Small footprint (high MLSS allows smaller aeration basin)
  • Excellent effluent quality (ready for disinfection or reuse)

Challenges:

  • Higher energy (aeration + membrane)
  • Fouling (requires frequent backwash, CEB, CIP)
  • Membrane replacement cost

Hybrid Systems ​

NF + RO:

  • NF removes hardness (prevent RO scaling)
  • RO operates at higher recovery (no CaSO₄ limit)
  • Lower overall energy (NF is lower pressure)

UF + RO:

  • UF provides excellent RO pretreatment (SDI <1, turbidity <0.05 NTU)
  • Allows higher RO flux (less fouling risk)
  • Multi-barrier for water reuse (virus + TDS removal)

Ozone + Ceramic MF:

  • Ozone pretreatment (oxidize organics, reduce biofouling)
  • Ceramic membranes (higher flux, easier cleaning, long life)
  • Drinking water applications
  • Rapid-Sand-Filter - Conventional pretreatment alternative
  • UV-Disinfection - Post-membrane disinfection
  • Chemical-Dosing - Antiscalant, dechlorination, coagulation
  • Sludge-Handling - Concentrate and backwash waste management

References ​

  1. Crittenden, J.C. et al. (2012). MWH's Water Treatment: Principles and Design, 3rd Ed., Wiley, Ch. 11-12.
  2. AWWA (2011). Water Quality and Treatment, 6th Ed., McGraw-Hill, Ch. 11: Membranes.
  3. Baker, R.W. (2012). Membrane Technology and Applications, 3rd Ed., Wiley.
  4. WEF (2018). Design of Municipal Wastewater Treatment Plants, MOP 8, 6th Ed., Ch. 17: Membrane Filtration.
  5. US EPA (2005). Membrane Filtration Guidance Manual, EPA 815-R-06-009.
  6. Judd, S. (2011). The MBR Book: Principles and Applications, 2nd Ed., Elsevier.
  7. Voutchkov, N. (2013). Desalination Engineering: Planning and Design, McGraw-Hill.