LOPA — Layer of Protection Analysis
Combine an initiating event with independent protection layers to compute mitigated risk, the gap to tolerable, and the required PFD / SIL for a new safeguard — CCPS LOPA.
Overview
A LOPA (Layer of Protection Analysis) is a semi-quantitative method that takes a single hazard scenario, multiplies the initiating-event frequency by the failure probabilities (PFDs) of the independent protection layers that stand between the initiating event and the consequence, and compares the resulting mitigated frequency with a tolerable target. If a gap remains, LOPA tells you the required PFD of an additional safeguard and the required SIL that implies.
ErgoPlanner enforces the defining rule of LOPA — that only independent protection layers may be credited — and computes the gap and required integrity automatically.
In this guide you'll learn
- How to create a LOPA study and define a scenario
- How to enter the initiating event and credit independent protection layers
- How the mitigated frequency, gap, required PFD and required SIL are computed
- How LOPA feeds the SIL verification
Estimated Time: 25 minutes Difficulty: Advanced
Prerequisites
- A signed-in account
- An engineering calculations entitlement to run the calculation
- A tolerable-frequency target for the consequence (from your corporate risk matrix)
- Familiarity with LOPA and IPL independence rules
Where to find it
The study list is at /lopa/studies; an individual study opens at /lopa/studies/{id}.
How the calculation works
For a scenario, ErgoPlanner computes the mitigated frequency as the initiating-event frequency reduced by every valid, independent protection layer (and any enabling-condition/modifier factors):
f_mitigated = f_IE × Π(modifiers) × Π(PFD of each independent IPL)It then compares f_mitigated with the tolerable target frequency to find the gap (how many times more risk reduction is still needed). The required PFD of an additional safeguard follows the CCPS rule:
required PFD = 1 / gapand that required PFD maps to a required SIL band per IEC 61511 (e.g. a required PFD of 0.1 → SIL 1, 0.01 → SIL 2, 0.001 → SIL 3).
Workflow
Step 1 — Create the study
- Go to
/lopa/studiesand click Create Study. - Enter a study name and optional description, and nominate a lead engineer.
- The study opens in Draft and progresses through In Progress → Verified → Approved → Closed.
Step 2 — Define a scenario
Add a scenario with:
- A scenario name / consequence description (e.g. "Reactor overpressure → rupture").
- The initiating event and its frequency (events per year).
- The tolerable target frequency for the consequence (per year).
Step 3 — Credit independent protection layers
Add the protection layers that act on this scenario. For each IPL choose a type and enter its data:
- Type — BPCS, Alarm, Relief Device, Operator Response, SIF, Modifier or Other.
- PFD — its probability of failure on demand.
- Independence — mark whether the layer is genuinely independent of the initiating event and of the other layers. Only independent layers are credited in the mitigated-frequency product; a layer flagged non-independent is excluded by the calculation. This independence gate is the heart of LOPA — it stops you double-counting a BPCS loop as both the initiating cause and a protection layer.
Enabling conditions and frequency modifiers can be added to adjust the initiating-event frequency (for example, fraction of time the hazardous condition exists).
Step 4 — Calculate
Click Calculate for the scenario. ErgoPlanner reports:
- Mitigated frequency —
f_IE × Π(modifiers) × Π(independent IPL PFDs). - Gap — how far the mitigated frequency still is from the tolerable target.
- Required PFD —
1 / gap, the PFD a new safeguard must achieve. - Required SIL — the IEC 61511 band that required PFD implies.
- Verdict — whether the scenario is already tolerable or needs an additional layer.
Step 5 — Close the loop into SIL
If the verdict calls for a new Safety Instrumented Function, carry the required SIL into a SIL assessment, build the SIF to that target, and verify that its achieved SIL meets the requirement.
Step 6 — Report
Click Report (PDF) in the study header to download the study report as lopa-<study name>.pdf. If it cannot be generated, an error message appears at the bottom right of the screen.
Worked example
Initiating event at 0.1 /yr, two independent IPLs (a BPCS alarm at PFD 0.1 and a relief valve at PFD 0.01), tolerable target 10⁻⁵ /yr:
f_mitigated = 0.1 × 0.1 × 0.01 = 1×10⁻⁴ /yr
gap = f_mitigated / target = 1×10⁻⁴ / 1×10⁻⁵ = 10
required PFD = 1 / gap = 0.1 → required SIL 1The scenario needs one more independent layer achieving PFD ≤ 0.1 — i.e. a SIL 1 SIF.
Use cases
- Sizing a new SIF — Establish, defensibly, the SIL target a new trip must meet before spending on instrumentation, then verify it in SIL.
- Crediting existing safeguards — Demonstrate that existing independent layers already make a scenario tolerable, avoiding unnecessary new hardware.
- Independence audit — Use the independence gate to expose layers that cannot legitimately be credited (e.g. sharing the BPCS with the initiating cause).
Related Topics
- Safety Analysis Suite
- SIL — Safety Integrity Level — verifies the required SIL this study produces
- HAZOP — Hazard & Operability Study — a common source of LOPA scenarios
References
- CCPS — Layer of Protection Analysis: Simplified Process Risk Assessment (AIChE)
- IEC 61511-3 — Guidance for the determination of the required safety integrity levels