Microfiltration (MF) ​

Pressure-driven membrane separation using 0.1-10 μm pore size for particle, bacteria, and protozoa removal, operating at 0.1-0.5 bar with fluxes of 50-150 LMH and achieving turbidity <0.1 NTU.

Overview ​

Microfiltration (MF) membranes provide an absolute barrier to particles, bacteria, and protozoa through size exclusion, producing high-quality effluent for water reuse or as pretreatment for reverse osmosis systems. MF operates at low transmembrane pressure (TMP), making it energy-efficient compared to higher-pressure membrane processes.

When to Use ​

  • Tertiary polishing (TSS removal to <1 mg/L)
  • Water reuse (non-potable to restricted potable)
  • RO pretreatment (reduce fouling potential)
  • Removal of Giardia and Cryptosporidium (4+ log)
  • Turbidity reduction for UV disinfection (<0.1 NTU)
  • Oil and grease removal (industrial wastewater)
  • MBR (membrane bioreactor) component
  • Drinking water treatment (coagulation + MF)

Key Characteristics ​

  • Pore size: 0.1-10 μm (typically 0.2-0.4 μm for wastewater)
  • Operating pressure: 0.1-0.5 bar (1-5 psi)
  • Permeate flux: 50-150 LMH (L/m²·h) for wastewater
  • Recovery: 90-98%
  • Turbidity removal: >99.9% (to <0.1 NTU)
  • Bacteria removal: >4 log (validated >6 log)
  • Protozoa removal: >4 log (Giardia, Cryptosporidium)
  • Virus removal: 0-2 log (size-dependent, not reliable barrier)
  • Backwash frequency: 15-60 minutes
  • CIP (clean-in-place): Weekly to monthly

Operating Modes ​

Basic Mode ​

  • Constant flux operation
  • Time-based backwash trigger
  • Default resistance model (clean membrane)
  • Simple TMP calculation
  • Fixed recovery ratio

Advanced Mode ​

  • Resistance-in-series fouling model
  • Backwash optimization (minimize water loss)
  • TMP-based backwash trigger (adaptive)
  • CEB (chemically enhanced backwash) scheduling
  • Flux stepping protocols
  • Fouling prediction and CIP planning

Mathematical Model ​

Darcy's Law (Flux Equation) ​

Permeate flux driven by transmembrane pressure:

$$J = \frac{\Delta P}{\mu \times R_{total}}$$

Where:

  • $J$ = permeate flux (L/m²·h or LMH)
  • $\Delta P$ = transmembrane pressure (TMP) (bar or Pa)
  • $\mu$ = dynamic viscosity (Pa·s), temperature-dependent
  • $R_{total}$ = total hydraulic resistance (m⁻¹)

Unit conversion: $$J [LMH] = \frac{\Delta P [bar] \times 10^5}{R_{total} [m^{-1}] \times \mu [Pa \cdot s]} \times 3600$$

Resistance-in-Series Model ​

Total resistance comprises multiple components:

$$R_{total} = R_m + R_c + R_{irr} + R_{rev}$$

Where:

  • $R_m$ = intrinsic membrane resistance (m⁻¹), constant
  • $R_c$ = cake layer resistance (m⁻¹), removed by backwash
  • $R_{irr}$ = irreversible fouling (m⁻¹), removed by CIP only
  • $R_{rev}$ = reversible fouling (m⁻¹), removed by backwash

Typical values for MF (wastewater):

  • $R_m$ = 1-5 × 10¹¹ m⁻¹ (clean membrane)
  • $R_c$ = 5-20 × 10¹¹ m⁻¹ (before backwash)
  • $R_{irr}$ = 2-10 × 10¹¹ m⁻¹ (accumulates over weeks)

Flux Decline During Filtration Cycle ​

Cake filtration model:

$$\frac{dR_c}{dt} = k_f \times C_b \times J^2$$

Where:

  • $k_f$ = fouling coefficient (s/m², depends on particle properties)
  • $C_b$ = bulk particle concentration (kg/m³)
  • $J$ = instantaneous flux (m/s)

Integration (constant TMP operation):

$$J(t) = \frac{J_0}{1 + \alpha \times t}$$

Where:

  • $J_0$ = initial flux (clean membrane)
  • $\alpha$ = fouling rate parameter

Temperature Correction ​

Viscosity varies strongly with temperature:

$$\mu_T = \mu_{20} \times \exp\left[\beta \times (20 - T)\right]$$

Where $\beta$ ≈ 0.025/°C for water

Flux correction:

$$J_T = J_{20} \times \frac{\mu_{20}}{\mu_T} \approx J_{20} \times 1.03^{(T-20)}$$

Example:

J₂₀ = 80 LMH @ 20°C
J₁₀ = 80 × 1.03⁻¹⁰ = 59 LMH @ 10°C (26% reduction!)

Backwash and Recovery ​

Backwash removes cake layer:

$$R_{total,after_BW} = R_m + R_{irr}$$

Recovery of flux:

$$\text{Flux recovery} = \frac{J_{after_BW} - J_{before_BW}}{J_{clean} - J_{before_BW}} \times 100%$$

Typical recovery: 80-95% per backwash

Net water production:

$$Recovery = \frac{V_{permeate}}{V_{feed}} = \frac{t_{filtration} \times J - t_{backwash} \times J_{BW}}{t_{filtration} \times J} \times 100%$$

Typical: 92-97% (3-8% backwash loss)

Design Parameters ​

Input Parameters ​

ParameterSymbolUnitRangeDefaultDescription
Pore size$d_p$μm0.1-100.4Nominal pore diameter
Design flux$J$LMH40-15080Net flux (averaged over cycle)
Operating TMP$\Delta P$bar0.1-0.50.2Transmembrane pressure
Temperature$T$°C5-3015Feed water temperature
Filtration cycle$t_f$min15-6030Time between backwashes
Backwash duration$t_{BW}$s30-9060Backwash time
Backwash flux$J_{BW}$LMH150-300200Reverse flux for cleaning
CEB frequency-cycles1-4824Backwashes between CEB
CIP frequency-days30-18090Days between CIP
Feed TSS-mg/L5-3015Influent suspended solids
Feed turbidity-NTU2-105Influent turbidity

Output Parameters ​

ParameterUnitDescription
Membrane aream²Required membrane surface area
Number of modules-Membrane cassettes or units
Permeate turbidityNTUEffluent turbidity (<0.1 typical)
TMP @ end of cyclebarMaximum TMP before backwash
Net water production%Recovery accounting for backwash
Backwash volumem³/dDaily water for backwash
CIP chemical cost$/yearNaOCl + citric acid
Energy consumptionkWh/m³Pumping energy
Log removal bacterialog₁₀Validated microbial removal

Configuration Guide ​

Step-by-Step Setup ​

  1. Select Membrane Pore Size

    Based on application:

    TSS removal only: 0.4-1.0 μm (higher flux, lower cost)
    Bacteria removal: 0.2-0.4 μm (standard)
    RO pretreatment: 0.1-0.2 μm (minimize fouling)
    Oil/grease: 0.4-0.8 μm (larger pore acceptable)
    
    Typical selection: 0.4 μm (balance of flux and removal)
  2. Determine Design Flux

    Conservative design for long membrane life:

    Secondary effluent (TSS 10-20 mg/L): J = 60-80 LMH
    Tertiary effluent (TSS <10 mg/L): J = 80-120 LMH
    RO pretreatment (low fouling): J = 100-150 LMH
    MBR configuration (submerged): J = 15-25 LMH (different regime)
    
    Recommendation: J = 80 LMH (conservative for wastewater)
  3. Calculate Membrane Area

    $$A = \frac{Q}{J \times R_{net}}$$

    Where $R_{net}$ = net production ratio (account for backwash)

    Example:
    Q = 10,000 m³/d = 417 m³/h
    J = 80 LMH
    R_net = 0.95 (5% backwash loss)
    
    A = 417 / (80 × 0.95) = 5,487 m²
  4. Select Membrane Modules

    Common module types:

    • Hollow fiber (HF): 20-50 m² per module
    • Flat sheet: 10-30 m² per module
    • Spiral wound (less common for MF): 30-40 m² per module
    Using hollow fiber @ 40 m²/module:
    Number of modules = 5,487 / 40 = 137 modules
    
    Organize into trains:
    4 trains × 35 modules = 140 modules total (allow 1 train for maintenance)
  5. Design Backwash System

    Backwash frequency:

    t_filtration = 30 minutes (typical)
    t_backwash = 60 seconds

    Backwash volume per cycle:

    A = 5,487 m²
    J_BW = 200 LMH (reverse flux)
    t_BW = 60 s = 1 min
    
    V_BW = A × J_BW × (t_BW / 60) = 5,487 × 200 × (1/60) = 18,290 L = 18.3 m³

    Daily backwash:

    Cycles per day = 24 × 60 / (30 + 1) = 46.5 cycles/d
    Daily BW volume = 46.5 × 18.3 = 851 m³/d
    
    Backwash % = 851 / 10,000 = 8.5%
    Net recovery = 91.5% ✓
  6. CEB (Chemically Enhanced Backwash) Design

    Frequency: Every 24 backwash cycles (once per day typical)

    Chemicals:

    • NaOCl: 50-200 ppm (oxidative cleaning, organics/biofilm)
    • Citric acid: 500-2000 ppm (mineral scale removal)

    Procedure:

    • Backwash with NaOCl solution (5-10 min contact)
    • Rinse with permeate
    • Backwash with citric acid (5-10 min contact)
    • Rinse with permeate
  7. CIP (Clean-in-Place) Design

    Frequency: Every 90 days (or when TMP increases 30%)

    Chemicals:

    • NaOCl: 500-1000 ppm (1-2 hour soak)
    • Citric acid or HCl: 0.5-2% (1-2 hour soak)
    • Caustic (NaOH): 0.1-0.5% (optional, for organic fouling)

    Procedure:

    • Recirculation cleaning (not backwash)
    • Soak steps with each chemical
    • Thorough rinsing
    • Integrity test before return to service
  8. Calculate Energy Consumption

    Feed pump:

    ΔP_total = TMP + ΔP_piping ≈ 0.2 + 0.3 = 0.5 bar
    Q_pump = Q_permeate / Recovery = 10,000 / 0.915 = 10,929 m³/d = 455 m³/h
    
    Power = (Q × ΔP) / (η × 3600) = (455 × 0.5 × 10⁵) / (0.75 × 3600) = 8.4 kW
    
    Daily energy = 8.4 × 24 = 202 kWh/d
    Specific energy = 202 / 10,000 = 0.02 kWh/m³ (very low!)

    Backwash pump:

    Q_BW = A × J_BW = 5,487 × 200 / 1000 = 1,097 m³/h (peak)
    ΔP_BW = 1.0 bar (higher for reverse flow)
    
    Power_BW = (1,097 × 1.0 × 10⁵) / (0.75 × 3600) = 40.6 kW (when running)
    Daily hours = 46.5 cycles × (60s / 3600s/h) = 0.78 hours
    Daily energy_BW = 40.6 × 0.78 = 31.6 kWh/d
    
    Total specific energy = (202 + 31.6) / 10,000 = 0.023 kWh/m³

Typical Design Values ​

ApplicationFlux (LMH)TMP (bar)Recovery (%)Backwash Freq (min)CIP Interval (days)
Tertiary TSS removal80-1000.15-0.2593-9730-6060-120
RO pretreatment100-1200.2-0.395-9830-4590-180
Water reuse70-900.15-0.2592-9520-4060-90
Industrial (high fouling)50-700.2-0.490-9315-3030-60

Performance Criteria ​

Removal Efficiency ​

ParameterInfluentPermeateRemoval
Turbidity2-10 NTU<0.1 NTU>99%
TSS10-30 mg/L<1 mg/L>98%
Bacteria (E. coli)10⁴-10⁶ cfu/100mL<1 cfu/100mL>4 log (validated >6 log)
Giardia cystsPresentNot detected>4 log (absolute barrier)
CryptosporidiumPresentNot detected>4 log (absolute barrier)
VirusesVariablePartial removal0-2 log (not reliable)
Dissolved organicsNo removalNo removal0% (MF is size exclusion only)
TDSNo removalNo removal0%

LRV (Log Removal Value) validation:

  • Challenge testing with surrogate microorganisms
  • Integrity testing (pressure decay, bubble point)
  • Direct removal testing (spiking studies)

Membrane Integrity Monitoring ​

Methods:

  1. Pressure decay test (offline): Detect pore size >3 μm
  2. Bubble point test (offline): Detect fiber breaks
  3. Turbidity monitoring (online): Permeate turbidity spike indicates breach
  4. Particle counting (online): Continuous LRV verification

Acceptance criteria:

  • Permeate turbidity: <0.15 NTU (alarm at 0.1 NTU)
  • Pressure decay: <5 mbar/min
  • Particle count (>2 μm): <10 counts/mL

Troubleshooting ​

IssueCauseSolution
Rapid TMP increase (fouling)High TSS in feedImprove upstream treatment, reduce flux
Backwash ineffectiveIncrease BW flux/duration, optimize CEB
Irreversible fouling (R_irr)Perform CIP, review chemical dosing
Temperature dropReduce flux proportionally with T
High permeate turbidityFiber break or seal leakIntegrity test, isolate faulty module
O-ring failureReplace seals, check assembly
Bypassing (channeling)Inspect module installation
Low flux even after CIPMembrane aging (permanent fouling)Replace membrane elements
Operating beyond design lifePlan membrane replacement
Incompatible chemical damageReview CIP chemicals vs. membrane material
High backwash frequencyFouling rate too highReduce flux, improve pretreatment
Particulate spikes in feedEqualization, upstream filtration
Excessive backwash water useBW duration too longOptimize to minimum effective time
BW flux too highReduce to 150-200 LMH
CIP not restoring fluxWrong chemical selectionOrganic: NaOCl; Inorganic: Acid; Both: Sequential
Inadequate contact timeIncrease soak time to 2-4 hours
Chemical concentration too lowIncrease NaOCl to 1000 ppm, acid to 2%
Membrane fiber breakageExcessive TMPLimit TMP to <0.5 bar, check control system
Mechanical stress (flow surges)Flow smoothing, pressure relief valves
Chemical attackCompatible chemicals only (check manufacturer)

Operation & Maintenance ​

Continuous Monitoring (Automated) ​

  • Permeate flow rate (each train)
  • TMP (transmembrane pressure)
  • Permeate turbidity (online)
  • Feed and permeate pressure
  • Backwash cycle counting
  • Chemical tank levels (CEB/CIP)

Daily Checks ​

  • Review TMP trend (flag if increasing >10%/week)
  • Verify permeate turbidity <0.1 NTU
  • Check backwash effectiveness (TMP drop after BW)
  • Inspect for leaks or unusual noises
  • Verify CEB chemicals available
  • Review flow balance (feed vs. permeate + backwash)

Weekly Maintenance ​

  • Perform integrity test (pressure decay or bubble point)
  • Calibrate turbidity meters
  • Inspect membrane modules (visual for fiber integrity)
  • Review TMP vs. flux trends
  • Check for air binding in modules
  • Clean strainers and pre-filters

Monthly Tasks ​

  • Detailed performance audit (flux recovery, TMP trends)
  • Particle count testing (permeate quality)
  • CEB optimization (review chemical effectiveness)
  • Inspect backwash pumps and valves
  • Review chemical consumption vs. design
  • Plan CIP if TMP increased >20-30%

Quarterly/CIP Events ​

  • Full CIP execution (NaOCl + acid sequence)
  • Post-CIP integrity testing
  • Document flux recovery (target: >90% of clean membrane)
  • Replace damaged modules if needed
  • Calibrate all pressure and flow instruments
  • Review membrane life (plan replacement if >5-7 years)

Annual Tasks ​

  • Comprehensive membrane performance review
  • Replace O-rings and seals (preventive)
  • Inspect all modules for fiber integrity
  • Review and optimize operating conditions (flux, BW, CEB)
  • Cost analysis: chemical, energy, membrane replacement
  • Regulatory compliance review (LRV validation)

Advanced Features ​

Flux Stepping Protocol ​

Gradually increase flux during filtration cycle to maintain constant TMP:

Benefits:

  • Constant energy consumption
  • Extended cycle time
  • Reduced backwash frequency

Implementation:

t = 0-10 min: J = 70 LMH (low fouling rate)
t = 10-20 min: J = 80 LMH
t = 20-30 min: J = 90 LMH (maximize production before BW)

Membrane Aeration (Submerged MF) ​

For submerged hollow fiber MF (common in MBR):

  • Air scour from below membranes
  • Air flow: 0.3-0.6 Nm³/m²·h
  • Reduces cake layer formation
  • Enables lower TMP operation

Two-Stage Backwash ​

  1. Air backwash (30 s): Dislodge cake layer
  2. Water backwash (30 s): Rinse out solids

Improves cleaning efficiency, reduces water use.

Ultrafiltration Hybrid (MF/UF) ​

Operate 0.1 μm MF membranes in UF pressure regime:

  • TMP: 0.5-1.0 bar (higher than typical MF)
  • Flux: 80-120 LMH
  • Virus removal: 2-3 log (improved over standard MF)

Worked Example ​

Given ​

  • Flow: 8,000 m³/d average
  • Feed: Secondary effluent, TSS = 15 mg/L, Turbidity = 5 NTU, Temperature = 12°C
  • Application: RO pretreatment (require turbidity <0.1 NTU)
  • Target recovery: 95%

Solution ​

Step 1: Select Membrane and Flux

Pore size: 0.2 μm (fine pore for RO pretreat)
Design flux @ 20°C: J₂₀ = 100 LMH (aggressive for RO feed quality)

Temperature correction:
J₁₂ = 100 × 1.03⁻⁸ = 78.9 LMH (use 80 LMH)

Step 2: Calculate Membrane Area

Q = 8,000 m³/d = 333 m³/h
Recovery = 0.95

A = Q / (J × Recovery) = 333 / (80 × 0.95) = 4,382 m²

Use 4,400 m² (allow 0.4% margin)

Step 3: Select Configuration

Hollow fiber modules @ 50 m²/module:
Modules = 4,400 / 50 = 88 modules

Organize: 4 trains × 22 modules = 88 total
(Each train = 1,100 m², can operate with 3 trains = 75% capacity)

Step 4: Design Backwash

t_filtration = 40 minutes
t_backwash = 60 s
J_BW = 200 LMH

Backwash volume = 4,400 × 200 × (1/60) = 14,667 L = 14.7 m³/cycle

Cycles/day = 24 × 60 / 41 = 35.1
Daily BW = 35.1 × 14.7 = 516 m³/d

Backwash % = 516 / 8,000 = 6.5%
Net recovery = 93.5% (slightly below 95% target, acceptable)

Step 5: CEB Design

Frequency: Once per day (35 backwash cycles)

NaOCl consumption:
Soak volume = membrane internal volume ≈ 0.1 × A = 440 L
Concentration = 100 ppm
NaOCl (12% solution) = 440 × 100 × 10⁻⁶ / 0.12 = 0.37 kg/d = 135 kg/year
Cost @ $500/tonne = $67/year (negligible)

Step 6: Energy Consumption

Feed pump:
ΔP_total = 0.25 + 0.25 = 0.5 bar (TMP + piping)
Q_feed = 8,000 / 0.935 = 8,556 m³/d = 356 m³/h
Power = (356 × 0.5 × 10⁵) / (0.75 × 3600) = 6.6 kW
Daily energy = 6.6 × 24 = 158 kWh/d

Backwash pump:
Q_BW = 4,400 × 200 / 1000 = 880 m³/h (peak)
ΔP_BW = 1.0 bar
Power_BW = (880 × 1.0 × 10⁵) / (0.75 × 3600) = 32.6 kW
Daily hours = 35.1 × (60/3600) = 0.58 h
Daily energy_BW = 32.6 × 0.58 = 19 kWh/d

Total energy = (158 + 19) / 8,000 = 0.022 kWh/m³
Annual energy cost @ $0.15/kWh = 177 × 365 × 0.15 = $9,686/year

Step 7: Verify Performance

Permeate turbidity: <0.1 NTU ✓ (MF specification)
TSS removal: 15 mg/L → <1 mg/L ✓
Bacteria removal: >6 log ✓
Recovery: 93.5% (close to 95% target) ✓

References ​

  1. Crittenden, J.C. et al. (2012). MWH's Water Treatment: Principles and Design, 3rd Ed., Ch. 11: Membranes.
  2. WEF (2018). Design of Municipal Wastewater Treatment Plants, MOP 8, 6th Ed., Ch. 17: Membrane Filtration.
  3. Metcalf & Eddy (2014). Wastewater Engineering, 5th Ed., pp. 1203-1241.
  4. AWWA (2011). Water Quality and Treatment, 6th Ed., Ch. 11: Microfiltration and Ultrafiltration.
  5. Judd, S. and Judd, C. (2011). The MBR Book: Principles and Applications of Membrane Bioreactors, 2nd Ed., Elsevier.
  6. US EPA (2005). Membrane Filtration Guidance Manual, EPA 815-R-06-009.
  7. Baker, R.W. (2012). Membrane Technology and Applications, 3rd Ed., Wiley.