Ozone Disinfection ​

Oxidative disinfection using dissolved ozone gas (O₃) to inactivate pathogens and oxidize micropollutants through powerful oxidation reactions, achieving 4+ log virus reduction with CT values of 0.5-1.0 mg·min/L while avoiding THM formation.

Overview ​

Ozone (O₃) is one of the strongest oxidizing disinfectants available (oxidation potential 2.07 V), providing rapid pathogen inactivation and simultaneous oxidation of color, taste/odor compounds, and trace organics. Ozone is generated on-site by electrical discharge through oxygen or air, dissolved into water via contact chambers, and residual ozone decomposes rapidly to oxygen. While highly effective, ozone requires significant capital investment and careful control to avoid bromate formation in bromide-containing waters.

When to Use ​

  • Water reuse (potable and non-potable)
  • Virus and protozoa inactivation (excellent for Cryptosporidium)
  • Color, taste, and odor removal (geosmin, MIB, phenols)
  • Micropollutant oxidation (pharmaceuticals, pesticides)
  • Pre-treatment for biological filtration (biodegradable organics)
  • No chlorinated DBP formation concerns (no THM/HAA)
  • When chlorine-resistant pathogens present
  • Advanced wastewater treatment

Key Characteristics ​

  • Pathogen inactivation: 4+ log virus, 3+ log Cryptosporidium (excellent)
  • CT value: 0.5-1.0 mg·min/L for 4-log virus (low contact time)
  • Rapid reaction (seconds to minutes)
  • No persistent residual (decays to O₂ in 10-30 min)
  • Strong oxidant: Removes color, oxidizes organics
  • Bromate (BrO₃⁻) formation concern if bromide >50 μg/L
  • High capital and operating cost
  • Energy: 8-15 kWh/kg O₃ produced

Operating Modes ​

Basic Mode ​

  • Fixed ozone dose
  • Simple CT calculation (C × T)
  • Constant residual target
  • Single contact chamber

Advanced Mode ​

  • CT validation with decay kinetics
  • Real-time ozone residual monitoring
  • Bromate formation control (pH, dose optimization)
  • Multi-stage contacting (optimize CT)
  • Advanced oxidation (ozone + H₂O₂ or UV)
  • Off-gas destruction control

Mathematical Model ​

Governing Equations ​

1. Ozone Disinfection - CT Concept ​

Pathogen inactivation by ozone follows CT (concentration × time):

$$\log\left(\frac{N}{N_0}\right) = -k_{O3} \times C \times T$$

Or:

$$CT = \frac{\log(N_0/N)}{k_{O3}}$$

Where:

  • $C$ = ozone residual concentration (mg/L)
  • $T$ = contact time (min)
  • $CT$ = disinfection parameter (mg·min/L)
  • $k_{O3}$ = ozone inactivation rate constant (L/mg·min), organism-specific
  • $N/N_0$ = surviving fraction

Required CT values for wastewater (typical):

  • 4-log virus: 0.5-1.0 mg·min/L
  • 3-log Giardia: 0.5-1.5 mg·min/L
  • 3-log Cryptosporidium: 5-10 mg·min/L (ozone excellent for Crypto!)

Example: For 4-log virus reduction (CT = 0.8 mg·min/L):

  • If C = 0.4 mg/L residual, T = 0.8 / 0.4 = 2 minutes
  • If C = 0.2 mg/L residual, T = 0.8 / 0.2 = 4 minutes

2. Ozone Demand and Dosing ​

Ozone demand is the ozone consumed by reactions before establishing residual:

$$D_{O3} = D_{demand} + C_{residual}$$

Where:

  • $D_{O3}$ = applied ozone dose (mg/L)
  • $D_{demand}$ = ozone demand (mg/L), consumed by organics, reduced species
  • $C_{residual}$ = target residual (mg/L)

Ozone demand varies with water quality:

  • DOC (dissolved organic carbon): 0.5-1.5 mg O₃ per mg DOC
  • Reduced iron (Fe²⁺): 0.43 mg O₃ per mg Fe²⁺
  • Reduced manganese (Mn²⁺): 0.88 mg O₃ per mg Mn²⁺
  • Nitrite (NO₂⁻): 1.1 mg O₃ per mg NO₂⁻-N
  • Sulfide (H₂S): 3.0 mg O₃ per mg H₂S-S

Total demand: $$D_{demand} = 1.0 \times DOC + 0.43 \times Fe + 0.88 \times Mn + \text{...}$$

Typical doses for tertiary effluent:

  • Low DOC (<5 mg/L): 3-6 mg/L O₃
  • Medium DOC (5-10 mg/L): 6-10 mg/L O₃
  • High DOC (>10 mg/L): 10-15 mg/L O₃

3. Ozone Decay Kinetics ​

Ozone residual decays over time:

$$C(t) = C_0 \times e^{-k_{decay} \times t}$$

Where:

  • $C(t)$ = ozone concentration at time t (mg/L)
  • $C_0$ = initial ozone concentration (mg/L)
  • $k_{decay}$ = decay rate constant (min⁻¹), water-specific

Decay rate depends on:

  • pH (faster at high pH)
  • Temperature (faster at high T)
  • Organic matter (scavenges ozone)
  • Catalysts (metals, hydroxide)

Typical half-life: 10-30 minutes in treated wastewater

4. Contact Time (T₁₀) ​

Use T₁₀ (time for 10% of flow to exit) for CT calculation to account for short-circuiting:

$$T_{10} = \frac{V_{contact}}{Q} \times f_{baffle}$$

Where:

  • $V_{contact}$ = contact chamber volume (L)
  • $Q$ = flow rate (L/min)
  • $f_{baffle}$ = baffling factor (0.3-0.7 for plug flow, 0.1-0.3 for mixed)

Design for plug flow: Baffled serpentine chambers, f = 0.5-0.7

5. Bromate Formation ​

Ozone oxidizes bromide (Br⁻) to bromate (BrO₃⁻), a potential carcinogen:

$$Br^- + O_3 \rightarrow BrO_3^-$$

Regulatory limit: BrO₃⁻ <10 μg/L (WHO, EU, UK)

Bromate formation depends on:

  • Bromide concentration (>50 μg/L problematic)
  • Ozone dose (higher dose → more bromate)
  • pH (lower pH reduces formation)
  • Contact time (longer time → more bromate)

Bromate control strategies:

  • Lower pH to 6.5-7.5 during ozonation
  • Minimize ozone dose (optimize for CT only)
  • Ammonia addition (scavenges ozone after disinfection)
  • Shorter contact time with higher ozone residual

6. Ozone Generation ​

Ozone produced by corona discharge:

$$3 O_2 + \text{energy} \rightarrow 2 O_3$$

Energy consumption:

  • Air-fed: 12-20 kWh/kg O₃
  • Oxygen-fed (LOX or PSA): 8-12 kWh/kg O₃

Ozone concentration in gas:

  • Air-fed: 1-3% O₃ by weight
  • Oxygen-fed: 6-12% O₃ by weight

Ozone transfer efficiency:

  • Venturi injector: 70-85%
  • Fine bubble diffuser: 85-95%
  • Sidestream injection: 90-98%

Design Parameters ​

Input Parameters ​

ParameterSymbolUnitRangeDefaultDescription
Flow rate$Q$m³/h10-5000500Design flow
Ozone dose$D_{O3}$mg/L3-158Applied dose
Target residual$C_{res}$mg/L0.2-0.50.3After demand satisfied
Contact time$T_{10}$min5-2010T₁₀ in contact chamber
Target CTCTmg·min/L0.5-2.01.0For 4-log virus
DOC-mg/L3-158Dissolved organic carbon
BromideBr⁻μg/L10-50050Bromate precursor
pH--6.5-8.07.5Operating pH
TemperatureT°C10-2515Water temperature

Output Parameters ​

ParameterUnitDescription
Ozone generator capacitykg O₃/hMaximum production rate
Contact chamber volumem³Volume for CT
Transfer efficiency%Ozone dissolution efficiency
Off-gas ozonemg/LResidual O₃ in off-gas (destroy)
Power consumptionkWGenerator electrical power
Specific energykWh/m³Energy per volume treated
Bromate concentrationμg/LPredicted BrO₃⁻ formation
Annual operating cost£/yearElectricity + O₂ + maintenance

Configuration Guide ​

Step-by-Step Setup ​

  1. Determine Ozone Dose

    Based on water quality and target:

    Demand calculation (example):
    DOC = 8 mg/L → 8 × 1.0 = 8.0 mg/L O₃
    Fe²⁺ = 0.5 mg/L → 0.5 × 0.43 = 0.2 mg/L O₃
    Total demand = 8.2 mg/L
    
    Target residual = 0.3 mg/L (for CT)
    Applied dose = 8.2 + 0.3 = 8.5 mg/L O₃

    Jar testing recommended to measure actual demand.

  2. Select Target CT Value

    For 4-log virus: CT = 0.8 mg·min/L (typical)
    With C_residual = 0.3 mg/L:
    T_10 required = 0.8 / 0.3 = 2.67 min
    
    Add safety factor (1.5×):
    T_10 design = 2.67 × 1.5 = 4.0 min
  3. Design Contact Chamber

    Plug flow serpentine chamber (preferred for CT):

    $$V_{contact} = Q \times T_{10} / f_{baffle}$$

    Q = 10,000 m³/d = 417 m³/h = 6,944 L/min
    T_10 = 4.0 min
    f_baffle = 0.6 (well-baffled)
    
    V_contact = 6,944 × 4.0 / 0.6 = 46,293 L = 46.3 m³

    Chamber configuration:

    • Serpentine channels with 180° bends
    • Number of baffles: 8-12 (maximize plug flow)
    • Depth: 3-5 m (maximize ozone residence, minimize off-gas)
  4. Select Ozone Generation Technology

    TechnologyOzone Conc.Energy (kWh/kg)Capital CostOperating Cost
    Air-fed corona1-3%12-20LowMedium (air dryer)
    PSA + corona6-10%8-12MediumMedium (electricity)
    LOX + corona10-12%8-10HighHigh (LOX supply)

    Recommendation: PSA (pressure swing adsorption) oxygen + corona for municipal systems (balance of cost and efficiency).

  5. Size Ozone Generator

    Ozone mass required = Q × D_O3 / transfer_efficiency
    
    Q = 10,000 m³/d = 417 m³/h
    D_O3 = 8.5 mg/L = 8.5 g/m³
    Transfer efficiency = 90% (sidestream injection)
    
    Ozone required = 417 m³/h × 8.5 g/m³ / 0.90 = 3,939 g/h = 3.94 kg/h
    
    Generator capacity (with 20% spare): 3.94 × 1.2 = 4.7 kg O₃/h
    Use 5 kg/h generator ✓
  6. Select Contacting Method

    MethodTransfer EfficiencyCapital CostMaintenanceHeadloss
    Venturi injector70-85%LowLowHigh (0.3-0.5 bar)
    Fine bubble diffuser85-95%MediumMedium (diffuser fouling)Low
    Sidestream injection90-98%HighLowLow

    Recommendation: Sidestream injection for large systems (high efficiency, low headloss).

  7. Design Off-Gas Destruction

    Ozone off-gas must be destroyed before venting:

    Methods:

    • Thermal destruction: Heat to 300°C (expensive)
    • Catalytic destruction: Manganese dioxide catalyst @ 60°C (common)
    • Activated carbon: Carbon bed adsorbs/decomposes O₃

    Design: Off-gas ozone concentration: 0.5-2.0% by weight (if 90% transfer) Catalytic destroyer efficiency: >99% (outlet <0.1 ppm O₃)

  8. Bromate Control

    If bromide >50 μg/L:

    Option 1: Lower pH to 6.8-7.2 during ozonation
    (Reduces bromate formation by 50-70%)
    
    Option 2: Add ammonia after ozone contact
    NH₃ dose: 0.5-1.0 mg/L (quenches residual ozone, prevents further bromate formation)
    
    Option 3: Minimize ozone dose (optimize CT)
    Use higher residual (0.4-0.5 mg/L) with shorter contact time
  9. Calculate Power and Operating Cost

    Generator capacity: 5 kg O₃/h
    Energy consumption: 10 kWh/kg O₃ (oxygen-fed)
    Power = 5 kg/h × 10 kWh/kg = 50 kW
    
    Daily energy = 50 kW × 24 h = 1,200 kWh/day
    Specific energy = 1,200 / 10,000 = 0.12 kWh/m³ ✓
    
    Annual costs:
    Electricity (@ £0.12/kWh): 1,200 × 365 × £0.12 = £52,560/year
    Oxygen (PSA maintenance): £5,000/year
    Maintenance (generator): £10,000/year
    Total: £67,560/year = £0.0068/m³ = 0.68 p/m³

Typical Design Values ​

ApplicationOzone Dose (mg/L)CT (mg·min/L)Contact Time (min)Specific Energy (kWh/m³)
Tertiary disinfection5-80.5-1.05-100.08-0.12
Color/odor removal3-60.3-0.65-100.05-0.10
Micropollutant oxidation8-121.0-2.010-150.12-0.18
Pre-treatment for BAC2-50.2-0.53-50.03-0.08
Potable reuse5-101.0-2.010-150.10-0.15

Performance Criteria ​

Pathogen Inactivation ​

OrganismCT for 4-log Reduction (mg·min/L)
E. coli0.02-0.05
Virus (poliovirus)0.5-1.0
Giardia cysts0.5-1.5
Cryptosporidium oocysts5-10

Note: Ozone excellent for Cryptosporidium (much better than chlorine).

Micropollutant Removal ​

Ozone oxidizes trace organics:

CompoundRemoval (%) @ 8 mg/L O₃
Pharmaceuticals (general)50-90
Carbamazepine80-95
Diclofenac90-99
Estrogens85-98
Geosmin/MIB (odor)90-99
Atrazine (pesticide)70-85

Bromate Formation ​

Predicted bromate based on bromide:

Bromide (μg/L)Ozone Dose (mg/L)pHPredicted BrO₃⁻ (μg/L)
5057.53-5
50107.58-12
10057.58-12
100107.515-25 (exceeds limit!)
100106.85-10 (pH control)

Troubleshooting ​

IssueCauseSolution
Insufficient CT (low residual)High ozone demandIncrease dose, improve pre-treatment
Ozone generator capacity insufficientAdd generator capacity
Poor transfer efficiencyCheck injector/diffuser, increase gas flow
High bromate formationHigh bromide in influentLower pH, minimize dose, add NH₃ quench
Excessive ozone doseOptimize dose for CT only
Generator low outputAir/oxygen feed contaminatedCheck desiccant dryer, replace filters
Corona tubes degradedReplace corona cells
Cooling water temperature highImprove cooling system
Off-gas ozone highCatalyst saturated or degradedReplace catalyst bed
Low temperature (catalyst inactive)Heat off-gas to 60°C
Poor disinfection performanceShort-circuiting in contact chamberImprove baffling, check T₁₀
Rapid ozone decayCheck pH, temperature, organic content
Corrosion of equipmentOzone attack on materialsUse ozone-resistant materials (SS 316, PTFE, PVC)
High operating costInefficient generatorService generator, check energy consumption
Excessive ozone doseOptimize dose via jar testing

Operation & Maintenance ​

Daily Checks ​

  • Monitor ozone residual (online analyzer)
  • Verify CT value achieved
  • Check generator output (kg O₃/h)
  • Record flow rate and dose
  • Inspect off-gas destroyer (ensure <0.1 ppm outlet)
  • Review effluent bacteria data

Weekly Maintenance ​

  • Measure ozone demand (jar test)
  • Calibrate ozone analyzers
  • Check desiccant dryer (air-fed systems)
  • Inspect contact chamber for algae/biofilm
  • Verify pH control system (if bromate control)

Monthly Tasks ​

  • Clean ozone analyzers (sensor fouling)
  • Inspect diffusers or injectors
  • Measure bromate concentration (lab analysis)
  • Check generator cooling system
  • Review power consumption trends

Annual Tasks ​

  • Service ozone generator (replace corona cells if needed)
  • Replace desiccant bed (air-fed)
  • Clean contact chamber (drain, inspect baffles)
  • Replace off-gas catalyst (if degraded)
  • CT validation study
  • Review performance vs. regulatory requirements

Generator Maintenance ​

Corona cells:

  • Life: 15,000-25,000 hours
  • Replace when output drops >20%

Desiccant dryer (air-fed):

  • Replace desiccant annually
  • Critical for generator efficiency

PSA oxygen system:

  • Zeolite bed life: 5-10 years
  • Annual inspection and testing

Advanced Features ​

Advanced Oxidation Process (AOP) ​

Ozone + H₂O₂ or Ozone + UV for enhanced oxidation:

$$O_3 + H_2O_2 \rightarrow \cdot OH + O_2$$

$$O_3 + UV \rightarrow O_2 + O \rightarrow \cdot OH$$

  • Hydroxyl radicals (·OH) are even more powerful than ozone (E₀ = 2.8 V)
  • Enhanced removal of recalcitrant organics
  • Application: Pharmaceuticals, industrial organics, PFAS precursors

Ozone + Biological Filtration ​

Ozone pre-treatment for biological activated carbon (BAC):

  • Ozone breaks down large organics into smaller, biodegradable molecules
  • Improved DOC removal in downstream GAC filter
  • Extended GAC bed life
  • Synergistic effect

Multi-Stage Ozonation ​

Optimize for both disinfection and oxidation:

  • Stage 1: Low dose (3-5 mg/L) for disinfection and initial oxidation
  • Stage 2: Higher dose (5-10 mg/L) for micropollutant oxidation
  • Minimize bromate by distributing dose

Real-Time Control ​

  • Ozone residual feedback control (PID loop)
  • CT monitoring and alarm
  • Bromate prediction model (dose optimization)
  • Generator output modulation based on demand

Worked Example ​

Given ​

  • Flow: 8,000 m³/d (average)
  • DOC: 10 mg/L
  • Bromide: 75 μg/L
  • Target: 4-log virus (CT = 0.8 mg·min/L)
  • Application: Indirect potable reuse

Solution ​

Step 1: Determine Ozone Demand

Ozone demand (empirical): 1.0 mg O₃ per mg DOC
D_demand = 10 × 1.0 = 10 mg/L O₃

Target residual: 0.4 mg/L (for CT)
Applied dose = 10 + 0.4 = 10.4 mg/L O₃

Step 2: Calculate Contact Time

CT_target = 0.8 mg·min/L
C_residual = 0.4 mg/L
T_10 = 0.8 / 0.4 = 2.0 min

With safety factor 1.5:
T_10 design = 2.0 × 1.5 = 3.0 min

Step 3: Design Contact Chamber

Q = 8,000 m³/d = 333 m³/h = 5,556 L/min
f_baffle = 0.6 (serpentine, well-baffled)

V_contact = 5,556 × 3.0 / 0.6 = 27,778 L = 27.8 m³

Chamber: 2m wide × 2m deep × 7m long (serpentine with baffles)

Step 4: Size Ozone Generator

Ozone required = 333 m³/h × 10.4 g/m³ / 0.92 (transfer eff.) = 3,766 g/h = 3.77 kg/h

With 25% spare capacity: 3.77 × 1.25 = 4.7 kg/h
Use 5 kg/h oxygen-fed generator ✓

Step 5: Assess Bromate Risk

Bromide = 75 μg/L (moderate risk)
Ozone dose = 10.4 mg/L (high)

Predicted bromate (empirical model):
BrO₃⁻ ≈ 0.10 × Br⁻(μg/L) × O₃(mg/L) / 10 = 0.10 × 75 × 10.4 / 10 = 7.8 μg/L

(Close to 10 μg/L limit—implement control)

Step 6: Bromate Control

Option: Lower pH from 7.5 to 7.0 during ozonation
Expected reduction: 40-50%
Predicted BrO₃⁻ with pH control: 7.8 × 0.55 = 4.3 μg/L ✓
(Below 10 μg/L limit)

Step 7: Calculate Operating Cost

Generator: 5 kg O₃/h × 10 kWh/kg = 50 kW
Daily energy = 50 × 24 = 1,200 kWh/day
Specific energy = 1,200 / 8,000 = 0.15 kWh/m³

Annual costs:
Electricity: 1,200 × 365 × £0.12 = £52,560/year
PSA maintenance: £5,000/year
Generator maintenance: £8,000/year
Total: £65,560/year = £0.0082/m³ = 0.82 p/m³

Step 8: Capital Cost Estimate

Ozone system (5 kg/h, oxygen-fed, installed): £400,000
- Generator: £150,000
- PSA oxygen system: £80,000
- Contact chamber: £100,000
- Off-gas destruction: £40,000
- Controls: £30,000

References ​

  1. Langlais, B., Reckhow, D.A., and Brink, D.R. (1991). Ozone in Water Treatment: Application and Engineering, Lewis Publishers.
  2. AWWA (2011). Water Quality and Treatment: A Handbook on Drinking Water, 6th Ed., McGraw-Hill, Ch. 7.
  3. WEF (2020). Advanced Wastewater Treatment Systems, WEFMOP 35, Ch. 8.
  4. von Gunten, U. (2003). "Ozonation of Drinking Water: Part II. Disinfection and By-Product Formation." Water Research 37(7): 1469-1487.
  5. EPA (2006). Ultraviolet Disinfection Guidance Manual, EPA 815-R-06-007 (includes ozone comparison).
  6. Haag, W.R. and Hoigné, J. (1983). "Ozonation of Bromide-Containing Waters: Kinetics of Formation of Hypobromous Acid and Bromate." Environ. Sci. Technol. 17(5): 261-267.
  7. Metcalf & Eddy (2014). Wastewater Engineering, 5th Ed., pp. 1480-1520.