Design Calculations Overview
Sizing and verification calculations for process units
Introduction
ErgoPlanner provides comprehensive design calculations based on industry standards and best practices. Use these tools to size equipment, verify capacity, and check design margins.
Calculation Categories
By Process
| Category | Units Covered |
|---|---|
| Preliminary | Screens, grit chambers |
| Primary | Clarifiers, settlers |
| Biological | Reactors, biofilm systems |
| Secondary | Final clarifiers, DAF |
| Tertiary | Filters, UV, membranes |
| Sludge | Thickeners, digesters |
By Method
| Method | Description |
|---|---|
| Sizing | Determine equipment dimensions |
| Verification | Check existing equipment capacity |
| Optimization | Improve performance parameters |
Design Standards
UK Water Industry
ErgoPlanner incorporates UK water company design criteria:
| Parameter | Typical Criteria |
|---|---|
| Primary retention | 2-3 hours at DWF |
| Secondary SOR | <1.0 m³/m²·h at 3DWF |
| Biofilter loading | 0.15-0.3 kg BOD/m³·d |
| Humus tank SOR | 1.2-2.0 m³/m²·h |
International Standards
| Standard | Coverage |
|---|---|
| WEF MOP 8 | Clarifier design |
| Ten States | US design standards |
| ATV-DVWK | German standards |
| ISO | Quality systems |
Detailed Guides
Primary Treatment
- Primary Tanks - Clarifier sizing
- Lamella settlers
- Imhoff tanks
Biological Treatment
- Biofilters - Trickling filter design
- Activated sludge sizing
- MBBR media calculations
Secondary Treatment
- Humus Tanks - Post-biofilter settling
- Secondary clarifier design
- DAF sizing
Chemical Systems
- Chemical Dosing - Dose calculations
- Storage tank sizing
- Mixing requirements
Key Design Parameters
Hydraulic Parameters
| Parameter | Symbol | Unit |
|---|---|---|
| Surface Overflow Rate | SOR | m³/m²·h |
| Hydraulic Loading Rate | HLR | m³/m²·d |
| Hydraulic Retention Time | HRT | hours |
| Weir Loading | WL | m³/m·h |
Organic Parameters
| Parameter | Symbol | Unit |
|---|---|---|
| Organic Loading Rate | OLR | kg BOD/m³·d |
| Food/Mass Ratio | F/M | kg/kg·d |
| Sludge Loading Rate | SLR | kg MLSS/m²·h |
| Solids Retention Time | SRT | days |
Design Workflow
Sizing New Units
mermaid
graph TD
A[Define Design Flow] --> B[Calculate Loads]
B --> C[Select Unit Type]
C --> D[Apply Design Criteria]
D --> E[Size Equipment]
E --> F[Verify Capacity]
F --> G{Acceptable?}
G -->|No| D
G -->|Yes| H[Document Design]Verification
- Input existing equipment data
- Define current/future loads
- Calculate utilization
- Identify bottlenecks
- Recommend upgrades
Where the calculation forms are
You do not need a simulation run to open a sizing form. The forms take an influent you enter and work it through in the browser, and the runs you save from them are kept against a project or a drawing — never against a simulation run.
There are two places to open them, and they are the same forms in both:
| Where | How to get there |
|---|---|
| Project detail page | Open the project → Calculations tab → Process calculations |
| Simulation editor | Bottom data panel → Calculation tab → Process calculations |
Pick a module from the Calculation module box — type to search it — and its form opens underneath. Ten modules are offered: flow and load, primary tanks, biofilters, humus tanks, chemical dosing, alkalinity balance, sludge production, ballasted precipitation (CoMag), the headroom report, and mass balance.
The project mount is the one to use for design work that has no model yet, and it shows the runs saved against that project. The editor mount is convenient while you are in a model, and lists every saved run for the module.
Sharing a link to a form
Whichever module you have open is written into the address bar, so the link in your browser is already a link to it:
/admin/projects/<project-id>?tab=calculations&calc=process&module=coMagSend that and your colleague lands on the same module. Reloading the page keeps you there too.
The editor's other surface, Unit sizing, is the one that does need a run — it reads flows and loads off a converged model for whichever unit is selected on the canvas. If no model has been run it says so, and points you at the Process calculations tab.
Using ErgoPlanner
Design Mode
- Select unit type
- Click Design Wizard
- Enter design criteria
- Review calculated dimensions
- Accept or modify
Verification Mode
- Enter existing dimensions
- Specify loading conditions
- View capacity analysis
- Export design report
Example: Primary Clarifier
Design Inputs
| Parameter | Value |
|---|---|
| Design flow | 10,000 m³/d |
| Peak flow | 30,000 m³/d |
| Influent TSS | 250 mg/L |
| Target removal | 60% |
Design Criteria
| Parameter | Criterion |
|---|---|
| HRT at DWF | >2 hours |
| SOR at 3×DWF | <1.5 m³/m²·h |
| Depth | 3.0-4.5 m |
| Weir loading | <10 m³/m·h |
Calculated Results
| Parameter | Value |
|---|---|
| Required area | 833 m² |
| Diameter | 33 m |
| Depth | 3.5 m |
| Volume | 2,917 m³ |
| HRT at DWF | 7.0 h |
| SOR at 3×DWF | 1.5 m³/m²·h |
Design Reports
ErgoPlanner generates comprehensive design reports:
- Equipment schedule
- Design calculations
- Drawing references
- Specification notes
Report Sections
- Design basis - Flows, loads, criteria
- Calculations - Step-by-step sizing
- Results - Final dimensions
- Verification - Capacity check
- Notes - Assumptions, references
Best Practices
- Apply safety factors - 1.2-1.5 for design
- Consider future loads - 20-year horizon
- Check all conditions - DWF, PWF, peak
- Document assumptions - For future reference
- Peer review - Independent check
Related Topics
References
- Metcalf & Eddy "Wastewater Engineering"
- WEF Manual of Practice No. 8
- UKWIR Design Guidelines
- Ten States Standards