Skip to content

Flow and Load Calculations - Design Basis ​

Flow and load calculations establish the hydraulic and pollutant loading basis for wastewater treatment plant design. This guide covers population equivalent (PE), dry weather flow (DWF), Formula A, and diurnal variations following UK PS201 standards and UK operator guidelines.

Population Equivalent (PE) ​

Population Equivalent converts all wastewater sources to an equivalent population for design purposes.

UK Standards ​

UK definition:

1 PE = 60 g BOD/person/day

EU directive (alternative):

1 PE = 54 g BOD/person/day (less conservative)

UK operator and most UK water companies use 60 g BOD/person/day

PE Components ​

Total PE calculation:

Total_PE = Domestic_PE + Non-Residential_PE + Commercial_PE + Trade_Equivalent

Domestic PE ​

From actual population:

Domestic_PE = Population (persons)

Assumes standard 60 g BOD/person/day

From housing:

Domestic_PE = Number_of_dwellings × Occupancy_rate

Where typical occupancy = 2.3-2.5 persons/dwelling (UK average 2.4)

Non-Residential PE ​

Schools, offices, light commercial:

Non_Residential_PE = BOD_load (kg/d) / 0.060 (kg/PE/d)

Typical values:

  • Schools: 0.02-0.03 PE/pupil/day
  • Offices: 0.01-0.02 PE/employee/day
  • Small shops: 0.05-0.10 PE/employee/day

Commercial PE ​

Restaurants, pubs, hotels:

Commercial_PE = BOD_load (kg/d) / 0.060

Typical values:

  • Restaurants: 0.3-0.5 PE/meal served
  • Pubs: 0.2-0.4 PE/customer/day
  • Hotels: 0.8-1.2 PE/bed

Trade Equivalent ​

Industrial discharges:

Trade_Equivalent = Trade_BOD_load (kg/d) / 0.060

Must be calculated from actual trade effluent data (consent conditions).


Dry Weather Flow (DWF) ​

DWF is the baseline flow for plant sizing.

DWF Formula ​

Standard formula:

DWF = P × PCC + I + E

Where:

  • DWF = Dry Weather Flow (m³/d or L/d)
  • P = Population or PE (persons)
  • PCC = Per Capita Consumption (m³/hd/d or L/hd/d)
  • I = Infiltration (m³/d or L/d)
  • E = Trade Effluent (m³/d or L/d)

Unit consistency: Use either all m³/d or all L/d. Common practice: calculate in L/d, convert to m³/d.

Per Capita Consumption (PCC) ​

Typical UK domestic values:

  • Urban areas: 130-150 L/hd/d
  • Rural areas: 100-120 L/hd/d
  • UK operator typical: 120-140 L/hd/d
  • Future planning: 150 L/hd/d (allows for growth)

Non-domestic allowances:

PCC_total = PCC_domestic + PCC_non-domestic

Infiltration (I) ​

Groundwater ingress into sewers.

Typical values:

  • Modern sewers: 1,000-3,000 L/d/km
  • Older sewers: 3,000-10,000 L/d/km
  • Combined sewers: 5,000-15,000 L/d/km

Calculation:

I = Sewer_length (km) × Infiltration_rate (L/d/km)

Example:

Sewer length = 10 km
Rate = 5,000 L/d/km

I = 10 × 5,000 = 50,000 L/d = 50 m³/d

Trade Effluent (E) ​

Industrial discharges.

Consented trade effluent:

E = Σ(Individual_consents)

Usually provided by water company or from trade effluent consent applications.

Example DWF Calculation ​

Design basis:

  • Population: 5,000 persons
  • PCC: 140 L/hd/d
  • Infiltration: 50 m³/d
  • Trade effluent: 100 m³/d

Calculation:

Domestic_flow = 5,000 × 140 / 1000 = 700 m³/d
Infiltration = 50 m³/d
Trade = 100 m³/d

DWF = 700 + 50 + 100 = 850 m³/d

Average Daily Flow and Diurnal Variations ​

Average Daily Flow (Q_MEAN) ​

UK operator standard:

Q_MEAN = DWF × F_MEAN

Where F_MEAN = 1.6 (UK operator typical diurnal factor)

Physical meaning: Accounts for peak hour flows during the day vs overnight minimums.

Example:

DWF = 850 m³/d
F_MEAN = 1.6

Q_MEAN = 850 × 1.6 = 1,360 m³/d

Diurnal Flow Pattern ​

Typical domestic pattern:

  • Minimum flow (02:00-04:00): 0.33 × average = 33% of daily average
  • Morning peak (08:00-10:00): 1.8-2.0 × average
  • Evening peak (18:00-20:00): 1.5-1.8 × average

Peak hour flow:

Q_peak = Q_MEAN × 1.5 to 2.5

Hourly variation important for:

  • Pumping station sizing
  • Storm tank design
  • Dosing system control

Storm Flows and Formula A ​

3 × DWF Threshold ​

Traditional UK storm flow threshold:

3DWF = DWF × 3

Flows above 3DWF are considered storm conditions.

Example:

DWF = 850 m³/d

3DWF = 850 × 3 = 2,550 m³/d

6 × DWF Maximum ​

Traditional maximum flow to full treatment:

6DWF = DWF × 6

Flows above 6DWF are diverted to storm tanks or overflow (after screening/settlement).

Example:

6DWF = 850 × 6 = 5,100 m³/d

Formula A (PS201) ​

Modern UK standard for calculating Full Flow to Treatment (FFT).

Formula:

FFT = DWF + 1.36 × P + 3.18 × √P

Where:

  • FFT = Full Flow to Treatment (m³/d)
  • DWF = Dry Weather Flow (m³/d)
  • P = Population in thousands (not PE!)

Derivation: PS201 Formula A accounts for storm flow contribution based on catchment size. Larger populations have proportionally lower per-capita storm contribution (economies of scale).

Example:

DWF = 850 m³/d
Population = 5,000 (= 5.0 thousand)

FFT = 850 + 1.36 × 5.0 + 3.18 × √5.0
FFT = 850 + 6.8 + 7.11
FFT = 863.9 m³/d

Note: For small populations, Formula A often gives FFT ≈ DWF. For larger populations (> 20,000), storm component becomes more significant.

Determining FFT for Design ​

Formula:

FFT = minimum of (3DWF, 6DWF, Formula_A, Consented_FFT)

Hierarchy:

  1. Consented limit (if specified in discharge permit)
  2. Formula A (PS201 calculation)
  3. 6 × DWF (traditional maximum)
  4. 3 × DWF (conservative threshold)

Example:

DWF = 850 m³/d
3DWF = 2,550 m³/d
6DWF = 5,100 m³/d
Formula A = 863.9 m³/d
Consented FFT = Not specified

FFT = minimum(2550, 5100, 863.9) = 863.9 m³/d (Formula A controls)

For this small population, Formula A is very conservative. Common practice: Use 3DWF as minimum.

FFT = max(3DWF, Formula_A) = max(2550, 863.9) = 2,550 m³/d

Pollutant Loads ​

BOD Load ​

Formula:

BOD_load = (PE × BOD_per_capita) + Trade_BOD

Where BOD_per_capita = 0.060 kg/PE/d (UK standard)

Concentration:

BOD_concentration = (BOD_load × 1000) / DWF

Example:

PE = 5,000
BOD_per_capita = 0.060 kg/PE/d
Trade_BOD = 10 kg/d (from consent)

BOD_load = 5,000 × 0.060 + 10 = 300 + 10 = 310 kgBOD/d

BOD_concentration = (310 × 1000) / 850 = 365 mg/L

TSS Load ​

Typical domestic ratio:

TSS_load = BOD_load × (TSS:BOD ratio)

Where UK typical TSS:BOD = 1.2 to 1.4

Example:

BOD_load = 310 kgBOD/d
Ratio = 1.3

TSS_load = 310 × 1.3 = 403 kgTSS/d

TSS_concentration = (403 × 1000) / 850 = 474 mg/L

Ammonia-N Load ​

Typical domestic:

NH₄-N_load = PE × 0.0125 kg NH₄-N/PE/d

UK typical: 12.5 g NH₄-N/person/day

Example:

PE = 5,000

NH₄_load = 5,000 × 0.0125 = 62.5 kgN/d

NH₄_concentration = (62.5 × 1000) / 850 = 73.5 mg/L

Total Phosphorus Load ​

Typical domestic:

TP_load = PE × 0.0025 kg TP/PE/d

UK typical: 2.5 g TP/person/day

Example:

PE = 5,000

TP_load = 5,000 × 0.0025 = 12.5 kg P/d

TP_concentration = (12.5 × 1000) / 850 = 14.7 mg/L

Chemical Oxygen Demand (COD) ​

Typical ratio:

COD_load = BOD_load × (COD:BOD ratio)

Where UK domestic typical COD:BOD = 2.0 to 2.5

Example:

BOD_load = 310 kgBOD/d
Ratio = 2.2

COD_load = 310 × 2.2 = 682 kgCOD/d

COD_concentration = (682 × 1000) / 850 = 802 mg/L

Design Summary Table ​

Worked Example Summary ​

ParameterValueUnitsNotes
Population5,000PEDesign population
PCC140L/hd/dPer capita consumption
Infiltration50m³/dGroundwater ingress
Trade effluent100m³/dIndustrial discharge
DWF850m³/dDry weather flow
Q_MEAN1,360m³/dAverage daily (F_MEAN = 1.6)
3 × DWF2,550m³/dStorm threshold
6 × DWF5,100m³/dTraditional maximum
Formula A864m³/dPS201 calculation
FFT (design)2,550m³/dUse 3DWF (conservative)
BOD load310kg/dIncluding trade
BOD concentration365mg/LAt DWF
TSS load403kg/dTSS:BOD = 1.3
TSS concentration474mg/LAt DWF
NH₄-N load62.5kg/d12.5 g/PE/d
NH₄-N concentration73.5mg/LAt DWF
TP load12.5kg/d2.5 g/PE/d
TP concentration14.7mg/LAt DWF
COD load682kg/dCOD:BOD = 2.2
COD concentration802mg/LAt DWF

Growth and Design Horizon ​

Population Growth ​

Formula:

P_future = P_current × (1 + r)^n

Where:

  • r = annual growth rate (decimal)
  • n = number of years (design horizon)

Typical design horizons:

  • Pumping stations: 10-15 years
  • Treatment plants: 15-25 years (phased expansion common)
  • Trunk sewers: 30-50 years

Example:

P_current = 5,000
Growth rate = 2% per year (r = 0.02)
Design horizon = 20 years

P_future = 5,000 × (1.02)^20 = 5,000 × 1.486 = 7,429 ≈ 7,500 PE

Future Flow ​

Account for:

  1. Population growth
  2. PCC increase (water use trends)
  3. Infiltration increase (sewer deterioration)
  4. New trade effluent

Example:

Future_PE = 7,500
PCC = 150 L/hd/d (increased from 140)
Infiltration = 75 m³/d (increased from 50)
Trade = 150 m³/d (new industry)

Future_DWF = 7,500 × 0.150 + 75 + 150 = 1,125 + 75 + 150 = 1,350 m³/d

UK Water Company Variations ​

UK Industry Practice ​

  • PE: 60 g BOD/person/day
  • PCC: 120-140 L/hd/d typical (150 for future)
  • F_MEAN: 1.6
  • Use Formula A for FFT, minimum 3DWF
  • NH₄-N: 12.5 g/PE/d
  • TP: 2.5 g/PE/d

UK Industry Practice ​

  • PE: 60 g BOD/person/day
  • PCC: 140-160 L/hd/d (London higher)
  • F_MEAN: 1.5-1.8 depending on catchment
  • FFT: Often use 6DWF for older works

UK Industry Practice ​

  • PE: 60 g BOD/person/day
  • PCC: 130-150 L/hd/d
  • F_MEAN: 1.6
  • Use Formula A, verified against 3DWF

Storm Tank Sizing ​

Traditional Method (68 L/hd) ​

Volume:

V_storm = P × 68 L/hd

Example:

P = 5,000

V_storm = 5,000 × 68 = 340,000 L = 340 m³

Modern Method (2-hour storm retention) ​

Volume:

V_storm = (Storm_flow - FFT) × Storm_duration

Where storm duration typically = 2 hours

Example:

Storm_flow = 6DWF = 5,100 m³/d = 212.5 m³/h
FFT = 2,550 m³/d = 106.25 m³/h
Storm_duration = 2 hours

V_storm = (212.5 - 106.25) × 2 = 212.5 m³

Modern method typically gives smaller tanks (cost-effective).


Flow Measurement and Verification ​

Flow Monitoring ​

Required for:

  • Consent compliance
  • Infiltration assessment
  • Treatment optimization
  • Billing (trade effluent)

Measurement locations:

  • Inlet works (total influent)
  • Return streams (sludge liquor)
  • Final effluent
  • Individual trade effluent connections

Typical accuracy:

  • Electromagnetic flowmeters: ±0.5%
  • Ultrasonic flowmeters: ±1-2%
  • Flumes/weirs: ±5-10%

Load Calculation from Flow and Concentration ​

Formula:

Load (kg/d) = (Flow (m³/d) × Concentration (mg/L)) / 1000

Example:

Flow = 850 m³/d
BOD = 365 mg/L

BOD_load = (850 × 365) / 1000 = 310.25 kg/d

Sensitivity Analysis ​

Always test sensitivity to key assumptions.

Example Sensitivity ​

Base case:

  • PE = 5,000
  • PCC = 140 L/hd/d
  • DWF = 850 m³/d

Scenario 1: High PCC (+20%)

PCC = 168 L/hd/d
DWF = 5,000 × 0.168 + 50 + 100 = 990 m³/d (+16%)

Scenario 2: Population growth (+50%)

PE = 7,500
DWF = 7,500 × 0.140 + 50 + 100 = 1,200 m³/d (+41%)

Scenario 3: High infiltration (double)

Infiltration = 100 m³/d
DWF = 700 + 100 + 100 = 900 m³/d (+6%)

Design recommendation: Size for worst-case combination or use phased expansion.


Common Design Errors ​

Under-Estimating Infiltration ​

Problem: Actual flows exceed design, especially in wet weather.

Solution:

  • CCTV survey of sewers
  • Flow monitoring campaign (12 months)
  • Allow 20-30% margin on infiltration estimate

Ignoring Future Growth ​

Problem: Plant undersized within 5 years.

Solution:

  • Use realistic growth rates (1-3% typical UK)
  • Design horizon 20-25 years
  • Phased expansion strategy

Over-Reliance on Formula A for Small Populations ​

Problem: Formula A gives unrealistically low FFT for small works.

Solution:

  • Use minimum of 3DWF for small works (< 10,000 PE)
  • Formula A more appropriate for larger works

Neglecting Trade Effluent Variations ​

Problem: Trade loads vary significantly, overwhelming treatment.

Solution:

  • Obtain actual trade effluent data (not just consent limits)
  • Include trade effluent safety factor (1.2-1.5×)
  • Monitor trade effluent contributions


References ​

  • UK Sewers for Adoption (7th Edition): Appendix PS201 - Flow and Load Calculations
  • UK operator Design Standards: Population equivalent and flow determination
  • CIRIA/WRc: Design flows for sewage treatment works
  • BS EN 752: Drain and sewer systems outside buildings

Navigation: