Flow and Load Calculations - Design Basis
Flow and load calculations establish the hydraulic and pollutant loading basis for wastewater treatment plant design. This guide covers population equivalent (PE), dry weather flow (DWF), Formula A, and diurnal variations following UK PS201 standards and UK operator guidelines.
Population Equivalent (PE)
Population Equivalent converts all wastewater sources to an equivalent population for design purposes.
UK Standards
UK definition:
1 PE = 60 g BOD/person/dayEU directive (alternative):
1 PE = 54 g BOD/person/day (less conservative)UK operator and most UK water companies use 60 g BOD/person/day
PE Components
Total PE calculation:
Total_PE = Domestic_PE + Non-Residential_PE + Commercial_PE + Trade_EquivalentDomestic PE
From actual population:
Domestic_PE = Population (persons)Assumes standard 60 g BOD/person/day
From housing:
Domestic_PE = Number_of_dwellings × Occupancy_rateWhere typical occupancy = 2.3-2.5 persons/dwelling (UK average 2.4)
Non-Residential PE
Schools, offices, light commercial:
Non_Residential_PE = BOD_load (kg/d) / 0.060 (kg/PE/d)Typical values:
- Schools: 0.02-0.03 PE/pupil/day
- Offices: 0.01-0.02 PE/employee/day
- Small shops: 0.05-0.10 PE/employee/day
Commercial PE
Restaurants, pubs, hotels:
Commercial_PE = BOD_load (kg/d) / 0.060Typical values:
- Restaurants: 0.3-0.5 PE/meal served
- Pubs: 0.2-0.4 PE/customer/day
- Hotels: 0.8-1.2 PE/bed
Trade Equivalent
Industrial discharges:
Trade_Equivalent = Trade_BOD_load (kg/d) / 0.060Must be calculated from actual trade effluent data (consent conditions).
Dry Weather Flow (DWF)
DWF is the baseline flow for plant sizing.
DWF Formula
Standard formula:
DWF = P × PCC + I + EWhere:
DWF= Dry Weather Flow (m³/d or L/d)P= Population or PE (persons)PCC= Per Capita Consumption (m³/hd/d or L/hd/d)I= Infiltration (m³/d or L/d)E= Trade Effluent (m³/d or L/d)
Unit consistency: Use either all m³/d or all L/d. Common practice: calculate in L/d, convert to m³/d.
Per Capita Consumption (PCC)
Typical UK domestic values:
- Urban areas: 130-150 L/hd/d
- Rural areas: 100-120 L/hd/d
- UK operator typical: 120-140 L/hd/d
- Future planning: 150 L/hd/d (allows for growth)
Non-domestic allowances:
PCC_total = PCC_domestic + PCC_non-domesticInfiltration (I)
Groundwater ingress into sewers.
Typical values:
- Modern sewers: 1,000-3,000 L/d/km
- Older sewers: 3,000-10,000 L/d/km
- Combined sewers: 5,000-15,000 L/d/km
Calculation:
I = Sewer_length (km) × Infiltration_rate (L/d/km)Example:
Sewer length = 10 km
Rate = 5,000 L/d/km
I = 10 × 5,000 = 50,000 L/d = 50 m³/dTrade Effluent (E)
Industrial discharges.
Consented trade effluent:
E = Σ(Individual_consents)Usually provided by water company or from trade effluent consent applications.
Example DWF Calculation
Design basis:
- Population: 5,000 persons
- PCC: 140 L/hd/d
- Infiltration: 50 m³/d
- Trade effluent: 100 m³/d
Calculation:
Domestic_flow = 5,000 × 140 / 1000 = 700 m³/d
Infiltration = 50 m³/d
Trade = 100 m³/d
DWF = 700 + 50 + 100 = 850 m³/dAverage Daily Flow and Diurnal Variations
Average Daily Flow (Q_MEAN)
UK operator standard:
Q_MEAN = DWF × F_MEANWhere F_MEAN = 1.6 (UK operator typical diurnal factor)
Physical meaning: Accounts for peak hour flows during the day vs overnight minimums.
Example:
DWF = 850 m³/d
F_MEAN = 1.6
Q_MEAN = 850 × 1.6 = 1,360 m³/dDiurnal Flow Pattern
Typical domestic pattern:
- Minimum flow (02:00-04:00): 0.33 × average = 33% of daily average
- Morning peak (08:00-10:00): 1.8-2.0 × average
- Evening peak (18:00-20:00): 1.5-1.8 × average
Peak hour flow:
Q_peak = Q_MEAN × 1.5 to 2.5Hourly variation important for:
- Pumping station sizing
- Storm tank design
- Dosing system control
Storm Flows and Formula A
3 × DWF Threshold
Traditional UK storm flow threshold:
3DWF = DWF × 3Flows above 3DWF are considered storm conditions.
Example:
DWF = 850 m³/d
3DWF = 850 × 3 = 2,550 m³/d6 × DWF Maximum
Traditional maximum flow to full treatment:
6DWF = DWF × 6Flows above 6DWF are diverted to storm tanks or overflow (after screening/settlement).
Example:
6DWF = 850 × 6 = 5,100 m³/dFormula A (PS201)
Modern UK standard for calculating Full Flow to Treatment (FFT).
Formula:
FFT = DWF + 1.36 × P + 3.18 × √PWhere:
FFT= Full Flow to Treatment (m³/d)DWF= Dry Weather Flow (m³/d)P= Population in thousands (not PE!)
Derivation: PS201 Formula A accounts for storm flow contribution based on catchment size. Larger populations have proportionally lower per-capita storm contribution (economies of scale).
Example:
DWF = 850 m³/d
Population = 5,000 (= 5.0 thousand)
FFT = 850 + 1.36 × 5.0 + 3.18 × √5.0
FFT = 850 + 6.8 + 7.11
FFT = 863.9 m³/dNote: For small populations, Formula A often gives FFT ≈ DWF. For larger populations (> 20,000), storm component becomes more significant.
Determining FFT for Design
Formula:
FFT = minimum of (3DWF, 6DWF, Formula_A, Consented_FFT)Hierarchy:
- Consented limit (if specified in discharge permit)
- Formula A (PS201 calculation)
- 6 × DWF (traditional maximum)
- 3 × DWF (conservative threshold)
Example:
DWF = 850 m³/d
3DWF = 2,550 m³/d
6DWF = 5,100 m³/d
Formula A = 863.9 m³/d
Consented FFT = Not specified
FFT = minimum(2550, 5100, 863.9) = 863.9 m³/d (Formula A controls)For this small population, Formula A is very conservative. Common practice: Use 3DWF as minimum.
FFT = max(3DWF, Formula_A) = max(2550, 863.9) = 2,550 m³/dPollutant Loads
BOD Load
Formula:
BOD_load = (PE × BOD_per_capita) + Trade_BODWhere BOD_per_capita = 0.060 kg/PE/d (UK standard)
Concentration:
BOD_concentration = (BOD_load × 1000) / DWFExample:
PE = 5,000
BOD_per_capita = 0.060 kg/PE/d
Trade_BOD = 10 kg/d (from consent)
BOD_load = 5,000 × 0.060 + 10 = 300 + 10 = 310 kgBOD/d
BOD_concentration = (310 × 1000) / 850 = 365 mg/LTSS Load
Typical domestic ratio:
TSS_load = BOD_load × (TSS:BOD ratio)Where UK typical TSS:BOD = 1.2 to 1.4
Example:
BOD_load = 310 kgBOD/d
Ratio = 1.3
TSS_load = 310 × 1.3 = 403 kgTSS/d
TSS_concentration = (403 × 1000) / 850 = 474 mg/LAmmonia-N Load
Typical domestic:
NH₄-N_load = PE × 0.0125 kg NH₄-N/PE/dUK typical: 12.5 g NH₄-N/person/day
Example:
PE = 5,000
NH₄_load = 5,000 × 0.0125 = 62.5 kgN/d
NH₄_concentration = (62.5 × 1000) / 850 = 73.5 mg/LTotal Phosphorus Load
Typical domestic:
TP_load = PE × 0.0025 kg TP/PE/dUK typical: 2.5 g TP/person/day
Example:
PE = 5,000
TP_load = 5,000 × 0.0025 = 12.5 kg P/d
TP_concentration = (12.5 × 1000) / 850 = 14.7 mg/LChemical Oxygen Demand (COD)
Typical ratio:
COD_load = BOD_load × (COD:BOD ratio)Where UK domestic typical COD:BOD = 2.0 to 2.5
Example:
BOD_load = 310 kgBOD/d
Ratio = 2.2
COD_load = 310 × 2.2 = 682 kgCOD/d
COD_concentration = (682 × 1000) / 850 = 802 mg/LDesign Summary Table
Worked Example Summary
| Parameter | Value | Units | Notes |
|---|---|---|---|
| Population | 5,000 | PE | Design population |
| PCC | 140 | L/hd/d | Per capita consumption |
| Infiltration | 50 | m³/d | Groundwater ingress |
| Trade effluent | 100 | m³/d | Industrial discharge |
| DWF | 850 | m³/d | Dry weather flow |
| Q_MEAN | 1,360 | m³/d | Average daily (F_MEAN = 1.6) |
| 3 × DWF | 2,550 | m³/d | Storm threshold |
| 6 × DWF | 5,100 | m³/d | Traditional maximum |
| Formula A | 864 | m³/d | PS201 calculation |
| FFT (design) | 2,550 | m³/d | Use 3DWF (conservative) |
| BOD load | 310 | kg/d | Including trade |
| BOD concentration | 365 | mg/L | At DWF |
| TSS load | 403 | kg/d | TSS:BOD = 1.3 |
| TSS concentration | 474 | mg/L | At DWF |
| NH₄-N load | 62.5 | kg/d | 12.5 g/PE/d |
| NH₄-N concentration | 73.5 | mg/L | At DWF |
| TP load | 12.5 | kg/d | 2.5 g/PE/d |
| TP concentration | 14.7 | mg/L | At DWF |
| COD load | 682 | kg/d | COD:BOD = 2.2 |
| COD concentration | 802 | mg/L | At DWF |
Growth and Design Horizon
Population Growth
Formula:
P_future = P_current × (1 + r)^nWhere:
r= annual growth rate (decimal)n= number of years (design horizon)
Typical design horizons:
- Pumping stations: 10-15 years
- Treatment plants: 15-25 years (phased expansion common)
- Trunk sewers: 30-50 years
Example:
P_current = 5,000
Growth rate = 2% per year (r = 0.02)
Design horizon = 20 years
P_future = 5,000 × (1.02)^20 = 5,000 × 1.486 = 7,429 ≈ 7,500 PEFuture Flow
Account for:
- Population growth
- PCC increase (water use trends)
- Infiltration increase (sewer deterioration)
- New trade effluent
Example:
Future_PE = 7,500
PCC = 150 L/hd/d (increased from 140)
Infiltration = 75 m³/d (increased from 50)
Trade = 150 m³/d (new industry)
Future_DWF = 7,500 × 0.150 + 75 + 150 = 1,125 + 75 + 150 = 1,350 m³/dUK Water Company Variations
UK Industry Practice
- PE: 60 g BOD/person/day
- PCC: 120-140 L/hd/d typical (150 for future)
- F_MEAN: 1.6
- Use Formula A for FFT, minimum 3DWF
- NH₄-N: 12.5 g/PE/d
- TP: 2.5 g/PE/d
UK Industry Practice
- PE: 60 g BOD/person/day
- PCC: 140-160 L/hd/d (London higher)
- F_MEAN: 1.5-1.8 depending on catchment
- FFT: Often use 6DWF for older works
UK Industry Practice
- PE: 60 g BOD/person/day
- PCC: 130-150 L/hd/d
- F_MEAN: 1.6
- Use Formula A, verified against 3DWF
Storm Tank Sizing
Traditional Method (68 L/hd)
Volume:
V_storm = P × 68 L/hdExample:
P = 5,000
V_storm = 5,000 × 68 = 340,000 L = 340 m³Modern Method (2-hour storm retention)
Volume:
V_storm = (Storm_flow - FFT) × Storm_durationWhere storm duration typically = 2 hours
Example:
Storm_flow = 6DWF = 5,100 m³/d = 212.5 m³/h
FFT = 2,550 m³/d = 106.25 m³/h
Storm_duration = 2 hours
V_storm = (212.5 - 106.25) × 2 = 212.5 m³Modern method typically gives smaller tanks (cost-effective).
Flow Measurement and Verification
Flow Monitoring
Required for:
- Consent compliance
- Infiltration assessment
- Treatment optimization
- Billing (trade effluent)
Measurement locations:
- Inlet works (total influent)
- Return streams (sludge liquor)
- Final effluent
- Individual trade effluent connections
Typical accuracy:
- Electromagnetic flowmeters: ±0.5%
- Ultrasonic flowmeters: ±1-2%
- Flumes/weirs: ±5-10%
Load Calculation from Flow and Concentration
Formula:
Load (kg/d) = (Flow (m³/d) × Concentration (mg/L)) / 1000Example:
Flow = 850 m³/d
BOD = 365 mg/L
BOD_load = (850 × 365) / 1000 = 310.25 kg/dSensitivity Analysis
Always test sensitivity to key assumptions.
Example Sensitivity
Base case:
- PE = 5,000
- PCC = 140 L/hd/d
- DWF = 850 m³/d
Scenario 1: High PCC (+20%)
PCC = 168 L/hd/d
DWF = 5,000 × 0.168 + 50 + 100 = 990 m³/d (+16%)Scenario 2: Population growth (+50%)
PE = 7,500
DWF = 7,500 × 0.140 + 50 + 100 = 1,200 m³/d (+41%)Scenario 3: High infiltration (double)
Infiltration = 100 m³/d
DWF = 700 + 100 + 100 = 900 m³/d (+6%)Design recommendation: Size for worst-case combination or use phased expansion.
Common Design Errors
Under-Estimating Infiltration
Problem: Actual flows exceed design, especially in wet weather.
Solution:
- CCTV survey of sewers
- Flow monitoring campaign (12 months)
- Allow 20-30% margin on infiltration estimate
Ignoring Future Growth
Problem: Plant undersized within 5 years.
Solution:
- Use realistic growth rates (1-3% typical UK)
- Design horizon 20-25 years
- Phased expansion strategy
Over-Reliance on Formula A for Small Populations
Problem: Formula A gives unrealistically low FFT for small works.
Solution:
- Use minimum of 3DWF for small works (< 10,000 PE)
- Formula A more appropriate for larger works
Neglecting Trade Effluent Variations
Problem: Trade loads vary significantly, overwhelming treatment.
Solution:
- Obtain actual trade effluent data (not just consent limits)
- Include trade effluent safety factor (1.2-1.5×)
- Monitor trade effluent contributions
Related Calculations
- Primary Tanks: DWF and FFT used for tank sizing
- Biofilters: BOD and NH₄-N loads for media sizing
- Humus Tanks: Hydraulic loading based on FFT
- Chemical Dosing: TP load for chemical dose
- Alkalinity Balance: NH₄-N load for alkalinity consumption
- Sludge Production: TSS load for sludge calculations
References
- UK Sewers for Adoption (7th Edition): Appendix PS201 - Flow and Load Calculations
- UK operator Design Standards: Population equivalent and flow determination
- CIRIA/WRc: Design flows for sewage treatment works
- BS EN 752: Drain and sewer systems outside buildings