Appearance
Design Standards
Industry standards and design criteria reference
Overview
ErgoPlanner incorporates design criteria from major international standards. This reference summarizes key design parameters.
UK Water Industry Standards
Sewers for Adoption (8th Edition)
| Parameter | Requirement |
|---|---|
| Minimum gradient (100mm) | 1:80 |
| Minimum gradient (150mm) | 1:150 |
| Minimum velocity | 0.75 m/s at 1/3 full |
| Maximum velocity | 3.0 m/s |
Design Flow Multiples
| Element | DWF Multiple |
|---|---|
| Primary settlement | 3 × DWF |
| Biological treatment | 3 × DWF |
| Final settlement | 3 × DWF |
| Storm tanks | 6 × DWF |
Preliminary Treatment
| Parameter | Criterion |
|---|---|
| Coarse screen spacing | 50-150 mm |
| Fine screen spacing | 3-6 mm |
| Grit channel velocity | 0.3 m/s |
| Grit chamber detention | 60 seconds |
Primary Settlement
| Parameter | Value |
|---|---|
| Retention at DWF | 2-3 hours |
| Retention at 3×DWF | 0.67-1.0 hour |
| Surface loading at 3×DWF | <1.5 m³/m²·h |
| Weir loading | <10 m³/m·h |
| Tank depth | 3.0-4.5 m |
Biological Filters
| Parameter | Low Rate | High Rate |
|---|---|---|
| Hydraulic loading | 0.1-0.4 m³/m²·h | 0.5-3.0 m³/m²·h |
| Organic loading | 0.08-0.15 kg/m³·d | 0.3-1.2 kg/m³·d |
| Media depth | 1.8-2.5 m | 1.2-2.0 m |
| Recirculation | Optional | 0.5-4.0:1 |
Humus Tanks
| Parameter | Criterion |
|---|---|
| Surface loading | 1.2-2.0 m³/m²·h |
| Retention time | >1.5 hours |
| Depth | 2.5-3.5 m |
Activated Sludge
| Parameter | Extended | Conventional |
|---|---|---|
| F/M ratio | 0.05-0.15 | 0.2-0.6 |
| MLSS | 3,000-6,000 | 1,500-3,000 |
| HRT | 18-36 h | 4-8 h |
| SRT | 20-40 d | 5-15 d |
Final Settlement
| Parameter | Criterion |
|---|---|
| Surface loading at DWF | <0.6 m³/m²·h |
| Surface loading at 3×DWF | <1.0 m³/m²·h |
| Solids loading | <5 kg/m²·h |
| Weir loading | <12 m³/m·h |
US Standards
Ten States Standards
| Unit | Key Criteria |
|---|---|
| Primary clarifiers | SOR ≤ 800 gpd/ft² at design |
| Aeration basins | Min 6h HRT at design |
| Secondary clarifiers | SOR ≤ 600 gpd/ft² at design |
| Digesters | Min 15 days HRT |
WEF/ASCE Guidelines
Refer to:
- WEF MOP 8: Clarifier Design
- WEF MOP 30: Nitrogen Removal
- WEF MOP 34: Nutrient Removal
European Standards
ATV-DVWK (German)
| Parameter | Criterion |
|---|---|
| Specific volume (ASP) | 1.5-2.0 L/PE |
| SVI design | <150 mL/g |
| Peak factor (small) | 2.5-3.0 |
| Peak factor (large) | 1.8-2.2 |
DIN Standards
| Standard | Coverage |
|---|---|
| DIN 4261 | Small treatment plants |
| DIN 4262 | Sewer construction |
| DIN EN 12255 | WWT plant standards |
Discharge Standards
UK Urban Waste Water Directive
| Parameter | Population | Limit |
|---|---|---|
| BOD₅ | >2,000 PE | 25 mg/L |
| COD | >2,000 PE | 125 mg/L |
| TSS | >2,000 PE | 35 mg/L |
| TN | >10,000 PE | 15 mg/L |
| TP | >10,000 PE | 2 mg/L |
Sensitive Area Limits
| Parameter | 10,000-100,000 PE | >100,000 PE |
|---|---|---|
| TN | 15 mg/L | 10 mg/L |
| TP | 2 mg/L | 1 mg/L |
Safety Factors
General Design
| Application | Safety Factor |
|---|---|
| Preliminary sizing | 1.2-1.5 |
| Detailed design | 1.1-1.25 |
| Nitrification capacity | 1.5-2.0 |
| Peak hydraulic | 3.0 × DWF |
Equipment Selection
| Equipment | Factor |
|---|---|
| Pumps | 1.1-1.2 |
| Blowers | 1.1-1.15 |
| Mixers | 1.15-1.25 |
| Standby units | N+1 minimum |
Process-Specific Criteria
Nitrification
| Parameter | Requirement |
|---|---|
| DO | >2.0 mg/L |
| Alkalinity | >50 mg/L as CaCO₃ |
| Temperature | >10°C |
| pH | 7.0-8.5 |
| SRT @ 10°C | >12 days |
Denitrification
| Parameter | Requirement |
|---|---|
| DO | <0.5 mg/L |
| C:N ratio | >4:1 (bsCOD:NO₃-N) |
| Temperature | >5°C |
| Anoxic fraction | 20-40% |
EBPR
| Parameter | Requirement |
|---|---|
| VFA:P ratio | >20:1 |
| Anaerobic HRT | 0.5-2.0 h |
| Anaerobic DO | 0 mg/L |
| Anaerobic NO₃ | <1 mg/L |
ErgoPlanner Integration
Automatic Checks
ErgoPlanner validates designs against:
- Selected standard (UK, US, EU)
- Design criteria databases
- Best practice guidelines
Warnings
Design warnings triggered when:
- Loading exceeds criteria
- Safety factors insufficient
- Parameters outside range
Reports
Generate compliance reports showing:
- Design vs criteria comparison
- Margin calculations
- Recommendations