Comprehensive UK-standard design calculations for wastewater treatment processes, covering primary sedimentation, biological filtration, settling tanks, chemical dosing, and sludge handling.
Overview
This section provides detailed design methodologies following UK water industry standards (PS208, PS211, PS221). Each calculation includes:
- Design equations with full derivations
- UK water industry standards and compliance criteria
- Worked examples with realistic values
- Parameter tables with acceptable ranges
- Related calculation dependencies
Design Calculation Topics
Primary Tanks
Primary sedimentation tank design per PS208 standards.
Key Parameters:
- Surface Overflow Rate: 1.0-1.2 m/h at DWF
- Retention time: 2-4 hours
- N-1 capacity requirements
- Sludge production estimates
Standards: UK PS208, UK operator guidelines
Biofilters
Trickling filter (biofilter) design per PS211 standards.
Key Parameters:
- BOD loading: 0.07 kgBOD/m³/d maximum
- Ammonia loading: 0.015 kgN/m³/d maximum
- Wetting rate: 0.04-0.75 m³/m²/h
- Recirculation requirements
Standards: UK PS211, biological treatment design
Humus Tanks
Secondary settling tank design per PS221 standards.
Key Parameters:
- Hydraulic loading: 1.0 m³/m²/h (all tanks), 2.0 m³/m²/h (N-1)
- Minimum HRT: 2 hours at maximum flow
- Minimum SWD: 2.0 m
- Humus sludge capture
Standards: UK PS221, UK operator design criteria
Chemical Dosing
Phosphorus removal using ferric sulphate with UK operator molar ratios.
Key Parameters:
- Fe:P molar ratios: 1.5-2.2 (typical 1.66)
- Dosing stages: primary, secondary, tertiary
- Storage requirements: 28 days supply
- Chemical sludge production
Standards: UK operator operational guidelines
Alkalinity Balance
Alkalinity consumption and supplementation for biological nutrient removal.
Key Parameters:
- Nitrification: 7.14 kg CaCO₃/kg NH₄-N
- Chemical dosing: 0.75 kg CaCO₃/kg Fe
- Minimum effluent alkalinity: 50 mg/L CaCO₃
- Sodium bicarbonate supplementation
Standards: Biological treatment chemistry
Sludge Production
Comprehensive sludge handling including production, thickening, and storage.
Key Parameters:
- Primary sludge: 40-60% SS removal
- Biological yield: 0.4-0.6 kgSS/kgBOD
- Storage: 14 days (UK operator), 4 days buffer
- Thickening targets: 3-6% DS
Standards: UK operator sludge management
Flow and Load
Hydraulic flow and pollutant load calculations for design basis.
Key Parameters:
- Population equivalent: 60g BOD/person/day (UK)
- DWF, 3DWF, 6DWF calculations
- Formula A (PS201) for FFT
- Diurnal flow factors
Standards: UK PS201, UK operator flow basis
Design Process Workflow
1. Flow and Load Basis
Start with Flow and Load calculations to establish:
- Design population (PE)
- Dry Weather Flow (DWF)
- Full Flow to Treatment (FFT via Formula A)
- Pollutant loads (BOD, SS, NH₄-N, TP)
2. Primary Treatment
Use Primary Tanks to design:
- Tank geometry (radial or rectangular)
- Verify PS208 compliance (upflow velocity, HRT)
- Check N-1 capacity
- Calculate primary sludge production
3. Biological Treatment
Design biofilters using Biofilters:
- Media volume based on BOD/NH₃ loading rates
- Recirculation requirements for wetting rate
- Temperature correction for efficiency
- Biomass production estimates
4. Secondary Settling
Size humus tanks per Humus Tanks:
- Surface area for hydraulic loading
- Verify PS221 compliance and N-1 capacity
- Humus sludge capture calculations
5. Phosphorus Removal (if required)
Apply Chemical Dosing:
- Determine dosing stage and Fe:P ratio
- Calculate chemical consumption
- Size storage tanks (28 days)
- Account for chemical sludge
6. Alkalinity Assessment
Check Alkalinity Balance:
- Calculate nitrification consumption
- Add chemical dosing consumption
- Verify effluent alkalinity ≥ 50 mg/L
- Size sodium bicarbonate dosing if needed
7. Sludge Management
Complete design with Sludge Production:
- Combine all sludge sources
- Calculate mixed sludge properties
- Design storage tanks (14 days UK operator)
- Assess liquor return impact
Key UK Standards Referenced
PS208 - Primary Sedimentation Tanks
- Maximum upflow velocity: 1.2 m/h (DWF), 2.0 m/h (FFT)
- Minimum retention time: 2 hours
- Minimum sidewater depth: 2.5 m
- N-1 compliance requirements
PS211 - Biological Filters
- Maximum BOD loading: 0.07 kgBOD/m³/d
- Maximum ammonia loading: 0.015 kgN/m³/d
- Wetting rate range: 0.04-0.75 m³/m²/h
PS221 - Humus Tanks
- Maximum HLR (all tanks): 1.0 m³/m²/h
- Maximum HLR (N-1): 2.0 m³/m²/h
- Minimum HRT: 2 hours
- Minimum SWD: 2.0 m
PS201 - Storm Flow Calculations
- Formula A: QFA = DWF + 1.36P + 3.18√P
- FFT determination
- Storm tank sizing
UK operator Operational Guidelines
- Fe:P molar ratios for phosphorus removal
- Sludge storage requirements (14 days)
- Alkalinity management criteria
Calculation Interdependencies
┌─────────────────┐
│ Flow and Load │ ← Start here: establish design basis
└────────┬────────┘
│
├──→ ┌─────────────────┐
│ │ Primary Tanks │ → Primary effluent quality
│ └────────┬────────┘
│ │
├──→ ┌───────▼─────────┐
│ │ Biofilters │ → Biomass production
│ └────────┬────────┘
│ │
├──→ ┌───────▼─────────┐
│ │ Humus Tanks │ → Humus sludge
│ └─────────────────┘
│
├──→ ┌─────────────────┐
│ │ Chemical Dosing │ → Chemical sludge, Fe dose
│ └────────┬────────┘
│ │
└──→ ┌───────▼─────────┐
│ Alkalinity │ → NaHCO₃ requirement
└─────────────────┘
│
┌───────▼─────────┐
│ Sludge Handling │ → Final storage design
└─────────────────┘Common Design Values (UK Practice)
Population Equivalent
- UK standard: 60g BOD/person/day
- EU standard: 54g BOD/person/day
- Per capita flow: 120-150 L/hd/d (domestic)
Diurnal Factors
- Peak flow factor: 1.5-2.5 × average
- Minimum flow factor: 0.33-0.50 × average
- FMEAN factor: 1.6 (UK operator standard)
Removal Efficiencies
- Primary tanks: 30-40% BOD, 50-60% SS
- Primary + chemical: 40% BOD, 60% SS, 70% TP
- Biofilters: 85% BOD, 85% NH₃
- Overall target: BOD ≤ 20 mg/L, SS ≤ 30 mg/L, NH₄-N ≤ 3 mg/L
Sludge Characteristics
- Primary sludge: 3-5% DS
- Humus sludge: 2% DS
- Mixed sludge: 2-4% DS (before thickening)
- Thickened sludge: 3-6% DS
Compliance Verification
When completing a design, verify compliance across all calculations:
Hydraulic compliance:
- Primary tanks: PS208 upflow velocities and HRT
- Biofilters: PS211 wetting rate range
- Humus tanks: PS221 hydraulic loading and HRT
Loading rate compliance:
- Biofilter BOD loading ≤ 0.07 kgBOD/m³/d
- Biofilter NH₃ loading ≤ 0.015 kgN/m³/d
N-1 redundancy:
- Primary tanks operable with one tank out
- Humus tanks operable with one tank out
- Blending tanks: minimum 2 for redundancy
Effluent quality targets:
- BOD ≤ 20 mg/L (or consent limit)
- SS ≤ 30 mg/L (or consent limit)
- NH₄-N ≤ 3 mg/L (or consent limit)
- TP ≤ 1 mg/L (if P removal required)
- Alkalinity ≥ 50 mg/L CaCO₃
Storage adequacy:
- Chemical storage: 28 days minimum
- Sludge storage: 14 days minimum (UK operator)
- Buffer tanks: 4 days typical