Appearance
Secondary Treatment - Clarification
Physical separation of biological solids from treated effluent using gravity settling and sludge thickening.
Overview
Clarification is the final step in secondary treatment, separating biomass from the treated mixed liquor to produce low-TSS effluent while thickening return sludge for biological process control.
Unit Operations
Secondary-Clarifier
Circular settling tanks with Takács double-exponential settling model for standard activated sludge applications.
Rectangular-Clarifier
Rectangular geometry for large plants, phased construction, and constrained linear sites.
Lamella-Clarifier
High-rate inclined plate settlers achieving 3-5× conventional overflow rates in compact footprint.
RAS-Pumping
Return and waste activated sludge pumping for MLSS control and SRT management.
Key Design Parameters
Surface Overflow Rate (SOR):
- Conventional: 15-30 m³/m²·d (average)
- Lamella: 60-120 m³/m²·d (projected area)
Solids Loading Rate (SLR):
- Target: 80-120 kg/m²·d (average)
- Peak: <200 kg/m²·d
Sludge Volume Index (SVI):
- Good: 80-120 mL/g
- Acceptable: 120-150 mL/g
- Bulking: >150 mL/g
Process Selection
| Criterion | Circular | Rectangular | Lamella |
|---|---|---|---|
| Plant size | Any | >20 MLD preferred | Any |
| Site constraints | Open area | Linear/constrained | Severely constrained |
| Footprint efficiency | Medium | Medium | High (1/3 conventional) |
| Capital cost | Low | Medium | High (per m²) |
| SVI tolerance | Good (<150) | Good (<150) | Requires <120 |
| Maintenance | Low | Medium | Medium-High |
References