Flow Measurement
Accurate flow measurement using weirs, flumes, or electromagnetic meters
Overview
Flow measurement is critical for process control, hydraulic design, and regulatory compliance. Common devices include Parshall flumes, V-notch weirs, rectangular weirs, venturi meters, and magnetic flow meters. Accuracy requirements: ±5% for daily, ±10% for instantaneous.
Theory - V-Notch Weir
$$Q = C \times \tan\left(\frac{\theta}{2}\right) \times \sqrt{2g} \times H^{2.5}$$
For 90° V-notch: $Q = 1.38 \times H^{2.5}$ (SI units: m³/s, m)
Theory - Rectangular Weir
$$Q = C \times L \times H^{1.5}$$
Where C = 1.84 for suppressed weir
Theory - Parshall Flume
$$Q = C \times H_a^n$$
Constants C and n depend on throat width
Parameters
| Device | Range | Accuracy | Headloss | Application |
|---|---|---|---|---|
| 90° V-Notch | 0.001-0.1 m³/s | ±2-5% | High | Clean water, low flow |
| Rectangular | 0.01-10 m³/s | ±3-5% | Moderate | General purpose |
| Parshall | 0.001-100 m³/s | ±3-5% | Low | Wastewater, wide range |
| Mag Meter | Any | ±0.5-2% | None | Pressurized pipes |
Worked Example
Given: 90° V-notch weir, H=0.25m Calculate: Flow
Q = 1.38 × 0.25^2.5 = 1.38 × 0.0884 = 0.122 m³/s = 122 L/s
References
- ISO 1438 (2017). Water flow measurement in open channels using weirs
- ASTM D5390. Parshall Flumes