Flow Measurement ​

Accurate flow measurement using weirs, flumes, or electromagnetic meters

Overview ​

Flow measurement is critical for process control, hydraulic design, and regulatory compliance. Common devices include Parshall flumes, V-notch weirs, rectangular weirs, venturi meters, and magnetic flow meters. Accuracy requirements: ±5% for daily, ±10% for instantaneous.

Theory - V-Notch Weir ​

$$Q = C \times \tan\left(\frac{\theta}{2}\right) \times \sqrt{2g} \times H^{2.5}$$

For 90° V-notch: $Q = 1.38 \times H^{2.5}$ (SI units: m³/s, m)

Theory - Rectangular Weir ​

$$Q = C \times L \times H^{1.5}$$

Where C = 1.84 for suppressed weir

Theory - Parshall Flume ​

$$Q = C \times H_a^n$$

Constants C and n depend on throat width

Parameters ​

DeviceRangeAccuracyHeadlossApplication
90° V-Notch0.001-0.1 m³/s±2-5%HighClean water, low flow
Rectangular0.01-10 m³/s±3-5%ModerateGeneral purpose
Parshall0.001-100 m³/s±3-5%LowWastewater, wide range
Mag MeterAny±0.5-2%NonePressurized pipes

Worked Example ​

Given: 90° V-notch weir, H=0.25m Calculate: Flow

Q = 1.38 × 0.25^2.5 = 1.38 × 0.0884 = 0.122 m³/s = 122 L/s

References ​

  1. ISO 1438 (2017). Water flow measurement in open channels using weirs
  2. ASTM D5390. Parshall Flumes