Gravity Thickener ​

Circular settling tank using gravity sedimentation and vertical picket rakes to concentrate sludge from 2-4% to 4-8% dry solids.

Overview ​

Gravity thickeners are the most economical method for thickening primary sludge and low-MCRT waste activated sludge (WAS). They operate on the principle of zone settling and compression, concentrating solids by allowing particles to settle while slowly raking settled sludge to a central underflow.

When to Use ​

  • Primary sludge thickening (highly effective, 6-8% DS achievable)
  • WAS from low F/M systems (MCRT <8 days)
  • Combined primary + WAS (blended feed)
  • Small to medium plants where footprint allows
  • When polymer-free thickening is desired

Key Characteristics ​

  • Simple, reliable operation
  • Low operating cost (no polymer)
  • Good for primary sludge (4-8% DS achievable)
  • Poor for extended aeration WAS (2-3% DS only)
  • Large footprint requirement
  • Potential for septicity and odor

Operating Modes ​

Basic Mode ​

  • Fixed solids flux rate based on sludge type
  • Simple overflow rate criterion
  • Default underflow concentration targets

Advanced Mode ​

  • State point analysis using Kynch theory
  • Dynamic flux curve based on SVI and sludge characteristics
  • Compression zone modeling
  • Real-time blanket level monitoring
  • Optimized picket speed control

Mathematical Model ​

Governing Equation - Solids Flux Theory ​

The limiting solids flux determines thickener area:

$$G_L = V_s(X) \times X + V_u \times X$$

Where:

  • $G_L$ = limiting solids flux (kg/m²·d)
  • $V_s(X)$ = settling velocity as function of concentration (m/h)
  • $X$ = solids concentration (kg/m³)
  • $V_u$ = underflow velocity (m/h)

Vesilind Settling Velocity ​

$$V_s = V_0 \times e^{-kX}$$

Where:

  • $V_0$ = maximum settling velocity (m/h), typically 5-15 m/h
  • $k$ = settleability constant (m³/kg), related to SVI
  • $X$ = solids concentration (kg/m³)

Relationship to SVI: $$k = \frac{0.35}{SVI}$$

Where SVI = Sludge Volume Index (mL/g)

State Point Analysis ​

The state point $(X_f, G_f)$ is where feed concentration meets the required flux:

$$A_{required} = \frac{Q \times X_f}{G_L}$$

Where:

  • $A_{required}$ = thickener surface area (m²)
  • $Q$ = feed flow rate (m³/d)
  • $X_f$ = feed solids concentration (kg/m³)

Underflow Concentration ​

For a given underflow rate $Q_u$:

$$X_u = \frac{Q \times X_f}{Q_u}$$

Practical maximum $X_u$:

  • Primary sludge: 60-80 kg/m³ (6-8% DS)
  • Low MCRT WAS: 40-50 kg/m³ (4-5% DS)
  • Extended aeration WAS: 20-30 kg/m³ (2-3% DS)

Solids Loading Rate ​

$$SLR = \frac{Q \times TSS_{in}}{A}$$

Where:

  • $SLR$ = solids loading rate (kg/m²·d)
  • Typical range: 30-60 kg/m²·d for primary, 15-30 kg/m²·d for WAS

Surface Overflow Rate ​

$$SOR = \frac{Q}{A}$$

Typical range: 15-30 m³/m²·d (low for WAS, high for primary)

Design Parameters ​

Input Parameters ​

ParameterSymbolUnitRangeDefaultDescription
Sludge type--Primary/WAS/MixedPrimaryFeed sludge characteristics
Feed concentration$X_f$% DS0.5-42.0Inlet solids concentration
Target underflow$X_u$% DS3-85.0Desired thickened concentration
SVI-mL/g50-250120Sludge volume index
Solids flux limit$G_L$kg/m²·d20-8040Design limiting flux
Picket speed$\omega$rpm0.01-0.050.02Rake rotation speed
Sidewater depth$H$m2.5-4.53.5Tank depth

Output Parameters ​

ParameterUnitDescription
Required aream²Surface area for design flux
Tank diametermCircular tank diameter
Underflow ratem³/dThickened sludge withdrawal
Overflow ratem³/dClarified liquid (return to plant)
Solids capture%Percentage of solids in underflow
Blanket depthmSettled sludge layer depth
Picket torquekWRake drive power requirement

Configuration Guide ​

Step-by-Step Setup ​

  1. Characterize Feed Sludge

    • Measure SVI (settling test)
    • Determine solids concentration
    • Identify sludge type (primary, WAS, mixed)
    • Calculate Vesilind parameters: $V_0$ and $k$
  2. Determine Target Underflow Concentration

    • Primary sludge: 6-8% DS
    • WAS (low MCRT): 4-5% DS
    • WAS (extended aeration): 2-3% DS
    • Mixed: 4-6% DS
  3. Calculate Required Area

    Method 1: Solids Flux (preferred)

    For primary sludge @ SVI=100:
    k = 0.35/100 = 0.0035 m³/kg
    V₀ = 10 m/h
    At X = 40 kg/m³: Vs = 10 × e^(-0.0035×40) = 7.4 m/h
    G = 7.4 × 40 = 296 kg/m²·d
    For Q=500 m³/d, Xf=20 kg/m³:
    A = (500 × 20)/296 = 33.8 m² → Use 40 m² (7.1m diameter)

    Method 2: Solids Loading Rate

    SLR = 50 kg/m²·d (primary sludge)
    Solids load = 500 × 20 = 10,000 kg/d
    A = 10,000/50 = 200 m²
  4. Select Tank Dimensions

    • Diameter: $D = \sqrt{4A/\pi}$
    • Depth: 3-4m (2.5m minimum for blanket control)
    • Freeboard: 0.3-0.5m
    • Bottom slope: 1:12 to center (or flat bottom)
  5. Design Picket Mechanism

    • Picket arms: 2-4 per radius
    • Picket height: 200-300mm
    • Picket spacing: 300-600mm vertically
    • Rotation: 0.01-0.05 rpm (1-3 hours per revolution)
    • Torque overload protection
  6. Configure Underflow Control

    • Time-based withdrawal (intermittent or continuous)
    • Blanket level sensor (ultrasonic or conductivity)
    • Variable speed pumps
    • Target blanket depth: 40-60% of sidewater depth

Typical Design Values ​

Sludge TypeSLR (kg/m²·d)SOR (m³/m²·d)Underflow DS (%)Depth (m)Picket Speed (rpm)
Primary40-6020-306-83.0-3.50.02-0.03
Low MCRT WAS20-4012-204-53.5-4.00.01-0.02
Extended aeration WAS10-258-152-33.5-4.50.01-0.02
Mixed (50/50)30-5015-254-63.0-4.00.02-0.03

Performance Criteria ​

Achievable Underflow Concentrations ​

Feed SludgeSVI (mL/g)Feed DS (%)Underflow DS (%)Volume Reduction (%)
Primary50-1002-46-870-85%
Primary100-1502-45-765-80%
WAS (MCRT 5-8d)80-1200.8-1.24-575-85%
WAS (MCRT 10-15d)120-1800.6-1.03-470-80%
WAS (extended aer.)150-2500.5-0.82-360-75%
Mixed80-1301.5-2.54-670-80%

Solids Capture ​

  • Typical: 95-98%
  • With good blanket control: >98%
  • Poor settling sludge: 90-95%

Overflow Quality ​

  • TSS: 100-500 mg/L (acceptable for return to head of plant)
  • Higher during upset or blanket loss
  • Biological sludge tends to have higher overflow TSS than primary

Troubleshooting ​

IssueCauseSolution
Low underflow concentrationExcessive withdrawal rateReduce underflow pumping, increase blanket level
Poor sludge settleability (high SVI)Reduce SRT, check for bulking, add polymer
Inadequate retention timeReduce feed rate, check for hydraulic overload
High overflow TSSHydraulic overload (high SOR)Reduce feed, add capacity
Blanket lossIncrease underflow rate, check picket operation
Rising sludge (septicity)Increase underflow frequency, reduce blanket depth
Picket torque alarmCompacted blanketIncrease underflow withdrawal immediately
Mechanical bindingStop, inspect, clear obstruction
Grit accumulationDrain and clean tank
Odor issuesSepticity in blanketIncrease underflow frequency, reduce retention
Dead zonesCheck picket coverage, ensure slow rotation
Anaerobic conditionsAeration not recommended (disrupts settling)
Poor primary thickeningGrease/FOG coating solidsPre-screen or skim, hot water washing
Lightweight particlesAdd coagulant or switch to DAF
FoamingBiological activity in blanketIncrease withdrawal, spray water on surface
SurfactantsDefoamer addition, reduce retention

Operation & Maintenance ​

Daily Checks ​

  • Visual inspection of overflow clarity
  • Monitor blanket level (ultrasonic or sludge judge)
  • Verify picket rotation (2-3 hours per revolution)
  • Check underflow concentration (jar test or online meter)
  • Observe torque indicator
  • Listen for unusual noises

Weekly Maintenance ​

  • Clean overflow weir
  • Check underflow pump operation
  • Verify blanket level sensors
  • Inspect feed distribution
  • Review withdrawal schedule effectiveness

Monthly Tasks ​

  • Measure SVI of feed and underflow
  • Calibrate blanket level instruments
  • Inspect picket mechanism (underwater camera or drain)
  • Check for grit accumulation
  • Review torque trends
  • Verify overflow return TSS with lab test

Annual Tasks ​

  • Drain and inspect tank interior
  • Full picket inspection and repair
  • Drive mechanism overhaul
  • Repaint exposed surfaces
  • Clean influent and effluent piping
  • Review performance vs. design

Advanced Features ​

Dynamic Blanket Control ​

Level-based withdrawal: $$Q_u = K \times (h_{blanket} - h_{target})$$

Where:

  • $Q_u$ = underflow rate (m³/h)
  • $K$ = control gain
  • $h_{blanket}$ = measured blanket level (m)
  • $h_{target}$ = setpoint (typically 1.5-2.0m)

Polymer Addition (Hybrid Thickening) ​

Adding low-dose polymer (0.5-2 kg/tonne DS) can:

  • Increase underflow concentration by 1-2%
  • Improve capture rate to >98%
  • Allow higher solids loading (+20-30%)

Cost-benefit: Polymer cost vs. downstream volume reduction

Temperature Effects ​

$$V_s(T) = V_s(20°C) \times 1.02^{(T-20)}$$

  • Cold weather (5°C): 30% reduction in settling velocity
  • Warm weather (25°C): 10% increase
  • Design for worst case (winter conditions)

Flocculation Zone ​

Some designs include gentle mixing zone ahead of thickener:

  • Low-intensity agitation (G = 20-50 s⁻¹)
  • 10-20 minute retention
  • Improves floc size and settling
  • Useful for poor settling sludge

Worked Example ​

Given ​

  • Primary sludge: 800 m³/d @ 3% DS
  • SVI: 90 mL/g
  • Target underflow: 6% DS
  • Temperature: 15°C

Solution ​

Step 1: Calculate Vesilind parameters

k = 0.35/90 = 0.00389 m³/kg
V₀ = 12 m/h (typical for primary)

Step 2: Construct flux curve

At X = 30 kg/m³: Vs = 12 × e^(-0.00389×30) = 3.68 m/h → G = 110 kg/m²·d
At X = 40 kg/m³: Vs = 12 × e^(-0.00389×40) = 2.51 m/h → G = 100 kg/m²·d
At X = 50 kg/m³: Vs = 12 × e^(-0.00389×50) = 1.71 m/h → G = 86 kg/m²·d
At X = 60 kg/m³: Vs = 12 × e^(-0.00389×60) = 1.17 m/h → G = 70 kg/m²·d (underflow target)

Step 3: Determine limiting flux

Feed: Xf = 30 kg/m³
State point analysis → G_L ≈ 100 kg/m²·d (conservative)

Step 4: Calculate area

A = (Q × Xf)/G_L = (800 × 30)/100 = 240 m²
D = √(4×240/π) = 17.5m → Use 18m diameter (254 m²)

Step 5: Verify SLR and SOR

SLR = (800 × 30)/254 = 94.5 kg/m²·d ✗ Too high!
Revise to D = 20m (314 m²)
SLR = 76.4 kg/m²·d ✓ (within 40-60 range, borderline)
SOR = 800/314 = 2.55 m/d ✓

Step 6: Underflow rate

Solids balance: 800 × 30 = Qu × 60
Qu = 400 m³/d
Volume reduction = (800-400)/800 = 50%

Step 7: Picket design

Depth: 3.5m
Picket speed: 0.02 rpm
Torque (empirical): 0.5 kW for 20m diameter

References ​

  1. WEF (2018). Design of Municipal Wastewater Treatment Plants, MOP 8, 6th Ed., Ch. 17.
  2. Metcalf & Eddy (2014). Wastewater Engineering, 5th Ed., pp. 1589-1610.
  3. Dick, R.I. (1970). "Role of Activated Sludge Final Settling Tanks." J. San. Eng. Div., ASCE.
  4. Vesilind, P.A. (1968). "Design of Prototype Thickeners from Batch Settling Tests." Water & Sewage Works.
  5. Ekama, G.A. et al. (1997). "Secondary Settling Tanks: Theory, Design and Operation." Water Research.
  6. CIWEM (2013). Sewage Sludge Treatment and Disposal, Manual of Practice.